25
6.4.
DVD Self Diagnostic Function Error Code
6.4.1.
Mechanism Error Code Table (DLS6E)
Error
Code
H01
Tray loading error
The tray opening and closing is abnormal. 
Press [     STOP] on main  
CLOSE and OPEN of the tray cannot be   
unit for next error.
carried out properly. Loading motor error,  
(OPEN time: OPEN
DV5 LSI IC (IC8001) error.
CLOSE         OPEN      
H01 at CLOSE: CLOSE
OPEN         CLOSE H01)
H02
Spindle servo error
The spindle servo/motor is abnormal. The 
Press [     STOP] on main
FG pulse is abnormal. CLV servo error. 
unit for next error.
H03
Traverse motor error
The traverse is abnormal. (Traverse servo, 
Press [     STOP] on main
DV5 LSI IC (IC8001), TRV motor error.) 
unit for next error.
H04
Tracking servo error
Tracking coil NG (OPU unit abnormal),
Press [     STOP] on main
DV5 LSI IC (IC8001) error.
unit for next error.
H05
Seek time out error
It is not possible to access the disc. TOC
Press [     STOP] on main
cannot read. Abnormal disc etc. Pickup
unit for next error.
abnormal or disk is dirty. (TRV motor 
error, DV5 LSI IC (IC8001) error.) 
H07
Driver IC thermal shut
The spindle motor is abnormal. 
Press [     STOP] on main
down
(short between brushes)
unit for next error.
U11
Focus servo error
Focus coil, FE signal error. Disc may be 
Press [     STOP] on main
dirty.
unit for next error.
(Unfinalized DVD-R
is likely to become 
U11.)
Description of error
Automatic FL Display
Remarks
Diagnosis  Contents
26
6.4.2.
DVD Module Error Code Table
Error
Code
U702 HDMI/DVI I2C
The communication error of I2C when
Press [     STOP] on main
communication error
connecting it with HDMI/DVI. For
unit for next error.
instance, when EDID information to which
information on the TV set side has been
described cannot be read, it is generated.
U703 HDMI/DVI attestation
When attestation (HDCP) with the TV
Press [     STOP] on main
error
side fails when connecting it with  
unit for next error.
HDMI/DVI, it is generated.
U704 HDMI/DVI SRM
It is generated at the equipment to which
Press [     STOP] on main
Riborcerar
the TV set is Riborced when connecting it
unit for next error.
with HDMI/DVI.
U705 HDMI/DVI SRM disk
It is generated at the time of it is time
Press [     STOP] on main
falsification check 
when illegal the SRM data of the  
unit for next error.
error
reproducing disk (verify error), when  
connecting it with HDMI/DVI.
F740 HDMI device key
I2C error when writing HDMI Key device
Press [     STOP] on main
into transmitter. 
unit for next error.
F893 FLASH ROM IC data 
Firmware error, DV5.0 LSI IC (IC8651)
Press [     STOP] on main
falsification error
error.
unit for next error.
F894 EEPROM IC
When failing in the access to EEPROM 
Press [     STOP] on main
abnormality error
IC located in the DVD Module P.C.B. 
unit for next error.
(IC8611).
F895 Language area 
Firmware version agreement check for  
Press [     STOP] on main
abnormal
factory preset setting failure prevention. 
unit for next error.
F897 Initialization 
Incomplete initialization after writing of 
Press [     STOP] on main
error
new firmware (Factory preset setting  
unit for next error.
failure prevention)
F899 The communication
Unsuitable combination of number of  
Press [     STOP] on main
specification 
system com and panel com used.
unit for next error.
disagreement
(Frimware)
between 
micro-processor
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
27
6.4.3.
Power Supply & Digital Amplifier Error Code Table
Error
Code
F61
The abnormalities
in the D-Amp related
problem (over-
temperature/shutdown)
In normal operation, when DCDET2 goes
Press [     STOP] on main
to "L" (Low) (Not during POWER OFF
unit for next error.
condition),  F61 appears on FL Display  
for 1 second and PCONT goes to
 "L" (Low).This is due to speaker output
has DC voltage.
F76
Abnormality in the 
In normal operation when DCDET1 is
Press [     STOP] on main
output voltage of 
detected "L" (Low) for two consecutive 
unit for next error.
stabilized power 
times, F76 is displayed on FL for 
supply
1 second and after that PCONT will be  
turned to "L" (Low). This is due to any of 
the DC voltages (+9V, +7V, -7V, +5V, 
+5.3V etc.) not available.
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
28
6.5.
Sales Demonstration Lock Function
This function prevents discs from being lost when the unit is used for sales demonstrations by disabling the disc eject function.
“LOCKED” is displayed on the unit, and ordinary operation is disabled.
6.5.1.
Setting
• Prohibiting removal of disc
1. Select the DVD/CD function.
2. At POWER ON condition, press and hold down the [ ] button and then [POWER] button on the main unit for at least three
seconds. (The message, “LOCKED” appears when the function is activated.)
Note:
OPEN/CLOSE 
 button is invalid and the main unit displays “LOCKED” while the lock function mode is entered.
• Prohibiting operation of selector and disc
1. Select the DVD/CD function.
2. At POWER ON condition, press and hold down the [ ] button and the [POWER] button on the main unit for at least three
seconds. (The message, “LOCKED” appears when the function is activated.)
Note:
The following buttons are invalid and the main unit displays “LOCKED” while the lock function mode is entered.
6.5.2.
Cancellation
 The lock can be cancelled by the same procedure as used in setting.(“UNLOCK” is displayed on cancellation) At normal Power
ON/OFF the LOCKED condition is not cleared.However AC Power ON/OFF should clear LOCKED condition).
Main unit
OPEN/CLOSE, , 
 Remote con-
troller unit
EXT-IN, REPEAT, RADIO, NUMERIC KEYS 0~9, 
,
,
,
,
,
,
,
RETURN, FUNCTIONS,
FL DISPLAY/SLEEP, MUTE 
Page of 122
Display

Click on the first or last page to see other SA-PT22GC / SA-PT22GW service manuals if exist.