Panasonic SA-PM500EG / SA-PM500EF / SA-PM500EP / SC-PM500EP Service Manual ▷ View online

17
7 Self Diagnostic and Doctor Mode Setting
This unit is equipped with features of self diagnostic & doctor mode setting for checking the functions & reliability.
7.1.
Self Diagnostic Mode
Here is the procedures to enter into Self Diagnostic Mode.
Step 1 : Turn on the unit.
Step 2 : Select CD mode.
Step 3 : Press and hold [Q] button for 2 seconds follow by [
] on the unit.
Step 4 : The display show as follow.
To exit the Self Diagnostic Mode
Use either one of the following methods to cancel the Self Diagnostic Mode.
• Press the power button on the main unit or using the remote control.
• Unplug the AC cord.
7.1.1.
Self Diagnostic Table
Self Diagnostic Mode
To enter into self diagnostic 
checking
Item
FL display
Key operation
Mode name
Description
Error code information
Delete Error code
Example:
System will perform a check on
any unusual/error code from the 
memory
To clear the stored in memory 
(EEPROM IC)
Step 1 : Select CD mode 
 
 
(Ensure no disc is inserted).
Step 2 : Press and hold [    ] follow by
 
[             ] on main unit for 2  
 second 
.
Step 1 : In self diagnostic mode, 
 
Press [STOP] on main unit.
 
To exit, press [
TA
] on main
 
unit or remote control.
Step 1 : In self diagnostic mode, 
   
Press [0] on remote control.
 
To exit, press [
TA
] on main
 
unit or remote control.
18
7.2.
Self Diagnostic Function Error Code
7.2.1.
CD Mechanism Error Code Table
7.2.2.
Power Amp Error Code Table
7.2.3.
iPod Error Code Table
Error Code
Diagnostic Contents
Description of error
Automatic FL Display
Remarks
CD H15
CD Open Abnormal
During operation 
POS_SW_R On fail to be 
detected with 4 sec. Error 
No. shall be clear by force 
or during cold start.
Press [ ] on main unit for 
next error.
CD H16
CD Closing Abnormal
During operation 
POS_SW_CEN On fail to 
be detected with 4 sec. 
Error No. shall be clear by 
force or during cold start.
Press [ ] on main unit for 
next error.
F26
Communication between 
CD servo LSI and micro-p 
abnormal.
During switch to CD func-
tion, if SENSE = “L” within 
failsafe time of 20ms.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description of error
Automatic FL Display
Remarks
F61/F76
Power Amp IC output 
abnormal
During power-on, PDET1, 
PDET2 & MAINV_DET / 
TEMP_DET is “L” after 1 
sec.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description of error
Automatic FL Display
Remarks
IPD H15
iPod Open Abnormal
During operation 
POS_SW_L On fail to be 
detected with 3 sec. Error 
No. shall be clear by force 
or during cold start.
Press [ ] on main unit for 
next error.
IPD H16
iPod Closing Abnormal
During operation 
POS_SW_CEN On fail to 
be detected with 3 sec. 
Error No. shall be clear by 
force or during cold start.
Press [ ] on main unit for 
next error.
19
7.3.
Doctor Mode Table
Here is the procedures to enter into Doctor Mode.
Step 1 : Turn on the unit.
Step 2 : Select CD mode.
Step 3 : Pressing and hold [Q] on main unit then press [4] follow by [7] using the remote control.
Step 4 : The display show as follow.
To exit the Doctor mode
Use either one of the following methods to cancel the Doctor mode.
• Press the power button of the unit or using the remote control.
• Unplug the AC cord.
20
7.3.1.
Doctor Mode Table 1
Item
FL Display
Key Operation
Mode Name
Description
Front Key
Doctor Mode
To enter into Doctor Mode 
for checking of various 
items and displaying 
EEPROM and firmware ver-
sion.
Note: The micro-processor 
version as shown is an 
example. It will be revise 
when there is an updates.
FL Display sequence Dis-
play 1 
¡  2
(Display 1)
Checksum : (Condition 1)
Checksum : (Condition 2)
Checksum : (Condition 3)
(Display 2)
The Checksum of EEPROM and firmware 
version will be display for 2 sec.
In any mode:
Press
 [    ] 
button on main unit follow by 
[4] & then [7] on remote control.
To exit Doctor Mode, press
 [
TA
]
button 
on main unit or remote control.
Version Display
(DEC)
Check sum
(HEX)
Version Display
(DEC)
No Rom correction
When EEPROM is not detected, it shall 
display only firmware version
When EEPROM is detected the version 
of the EEPROM does not match or not 
working properly [NG] is display.
When EEPROM is detected, it shall
display the [YYYY].
Page of 115
Display

Click on the first or last page to see other SA-PM500EG / SA-PM500EF / SA-PM500EP / SC-PM500EP service manuals if exist.