DOWNLOAD Panasonic SA-MAX700GSK Service Manual ↓ Size: 12.16 MB | Pages: 124 in PDF or view online for FREE

Model
SA-MAX700GSK
Pages
124
Size
12.16 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / CD STEREO SYSTEM
File
sa-max700gsk.pdf
Date

Panasonic SA-MAX700GSK Service Manual ▷ View online

21
8.2.2.
Doctor Mode Table 2
FL Display
Key Operation
Front Key
Item
Description
Mode Name
Volume Setting 
Check
FL Display Check
To check the volume setting of the 
main unit.
To check the FL segment display.
All segments will light up while all LED
blink at 0.5s intervals.
In Doctor Mode:
1. Press [7], [8], [9] button on 
the remote control.
In Doctor mode:
1. Press [1] button on the
remote control.
2. To cancel this mode, press
[0] button on the remote control.
Press [7]: VOL50
Press [8]: VOL35
Press [9]: VOL0
Volume
In this mode, the tray will open & close 
automatically.
Cancellation Display
Loading Test
To determine the open & close 
operation of the CD Mechanism Unit.
Note: Refer to Section 8.3 Figure 8-2
for process flow
Note: Refer to Section 8.3 Figure 8-3
for process flow
Note: Refer to Section 8.3 Figure 8-1
for process flow
.
The counter will
increment by one.
When reach 99999999
will change to 00000000
Cancellation Display
Traverse Test
To determine the traverse unit 
operation for inner & outer access track.
The counter will 
increment by one. 
When reach 99999999 
will change to 00000000
The counter will 
increment by one. 
When reach 99999999 
will change to 00000000
Cancellation Display
Reliability Test 
(Combination)
In this mode,ensure the CD is in the 
main unit.
To determine the traverse unit
operation & open/close operation of the
mechanism.
In this mode,ensure the CD is in the 
main unit.
In Doctor Mode:
1. Press [10]    [2]    [1] button 
on the remote control.
In Doctor Mode:
2. To cancel this mode, press
[0] button on the remote control.
1. Press [10]    [1]    [2] button 
on the remote control.
In Doctor Mode:
1. Press [10]    [1]    [5] button
on the remote control.
2. To cancel this mode, press
[0] button on the remote control.
2. To cancel this mode, press
[0] button on the remote control.
22
8.2.3.
Doctor Mode Table 3
FL Display
Key Operation
Front Key
Item
Description
Mode Name
CD
Self- Adjustment 
Test
To  display result of 
self-adjustment for CD.
CD LSI Version
Check
For checking CD LSI Version and
checksum information.
In Doctor Mode:
1. Press [10]    [1]    [4] button 
on the remote control.
In Doctor Mode:
1. Press [4] button on the 
remote control.
Display of auto adjustment
result
Reference table:
ERROR Code
Status
Condition
0   1   2   4   6   8   A   C   E   F
AOC1/AOC2 O        O  O  O  O   O  O  O   -
ABC2/ABC1
O   -   X   O   X  O   X  O   X   -
2
nd
 AOC1
O   -   O   X   X  O   O  X   X   -
FAGC/TAGC O   -   O   O  O   X  X   X   X   -
AGC2
O   -   O   O  O  O   O  O  O
O : OK;
X : NG (In case that time out happens.)
   : Either one of FO AOC, TR AOC and FO
     coarse AGC is NG.
   : If the AGC is NG (ignore others). 
To cancel this mode, press [0]
button on the remote control.
To cancel this mode, press [0]
button  on the remote control.
(Display 2)
(Display 1)
Version (Decimal)
ROM
Type
Year Develop
after
2 sec
Checksum (Hex)
23
8.3.
Reliability Test Mode (CD Mechanism Unit)
Below is the process flow chart of the aging test for the CD Mechanism Unit .
Fig. 1. Reliability Test (Loading)
 
Fig. 2. Reliability Test (Traverse)
 
Fig. 3. Reliability Test (Combination)
OPEN
Operation
OPEN wait
for 1 s 
CLOSE
Operation
CLOSE wait
for 4 s 
Count up
First Track
Access
First Track
Play 5 s
Last Track
Access
Last Track
Play 5 s
Count up
First Track
Access
Access
Play 10 s 
Open
Operation
Open wait
for 1 s 
CLOSE
Operation
Count up
First Track
Last Track
Last Track
Play 10 s 
24
8.4.
Self-Diagnostic Mode
8.5.
Self-Diagnostic Error Code Table
Self-Diagnostic Function (Refer Section 8.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and
its respective components by displaying the error codes. These error code such as U**, H** and F** are stored in memory and held
unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
8.5.1.
Power Supply Error Code Table
FL Display
Key Operation
Front Key
Item
Description
Mode Name
To enter into self diagnostic checking
System will perform a check on any 
unusual/error code from the memory
To clear the stored in memory 
(EEPROM IC)
Self Diagnostic
Mode
Error code 
information
Delete error 
code
Step 1: Select CD mode
             (Ensure no disc is inserted).
Step 2: Press & hold [   ] button 
             follow by  [      
] on 
             main unit for 2 seconds.
Step 1: In self diagnostic mode,
            Press [   ] on main unit.
            To exit, press [
^
/I] on main
            unit or remote control.
Step 1: In self diagnostic mode,
            Press [0] on remote control.
            To exit, press [
^
/I] on main
            unit or remote control.
Example:
/
Cold Start
To active cold start upon next AC
power up when reset start is
execute the next time.
In
self diagnostic mode
:
1. Press [3] button on 
the remote control.
Page of 124
Display

Click on the first or last page to see other SA-MAX700GSK service manuals if exist.