DOWNLOAD Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual ↓ Size: 15.68 MB | Pages: 127 in PDF or view online for FREE

Model
WH-SXC09H3E5 WH-SXC12H6E5 WH-UX09HE5 WH-UX12HE5
Pages
127
Size
15.68 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR-TO-WATER HEATPUMP
File
wh-sxc09h3e5-wh-sxc12h6e5-wh-ux09he5-wh-ux12he5.pdf
Date

Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual ▷ View online

21 
Select this icon to delete (cancel) or change the pre-set
Weekly Timer.
Press
 to confirm your selection.
• Timer is not ON.
• Timer is set.
After 1 sec delay.
Weekly
Timer
Select “Yes”.
• If you select “No”, the screen will return to the Main Screen.
• Timer Setup: Select Timer setup to edit the Weekly Timer.
• Timer copy: Select to copy a timer setting.
[Example of a Timer setup]
Select the day(s) which you wish to edit using
 buttons.
If all 6 patterns are not preset, this screen will be displayed.
1
2
3
4
5
6
Select pattern “1” ~ “6”.
Set the hour and minutes of the Timer.
Select ON/OFF of the Timer.
Select the operation mode.
 /
• Select mode using
 buttons.
Set the temperature for both Zone 1 and 2
(if your system has the 2-Zone setting).
Set the Tank temperature.
Note:
• Timer is disabled when Force Heater is turned on or Heat-Cool SW is enabled.
• If you have preset the Weekly Timer on 2 zones, you must repeat the same procedure with Zone 2.
 
/
 
/
 
/
 
/
 
/
 
 
22 
Select to defrost the frozen pipes.
Press
 to confirm your selection.
(When the mode is accepted, below screen will be displayed.)
Force
Defrost
Select to restore the previous settings when error has
occurred.
Press
 to confirm your selection.
(When the mode has been accepted, below screen will be displayed.)
• Make sure all units are turned off before
selecting this mode which restores the whole
system to the previous settings.
Error Reset
Select to lock the Remote Controller.
Press
 to confirm your selection.
(When the mode has been accepted, below screen will be displayed.)
Select “Yes”.
(The Main Screen will be locked.)
• If “No” is selected, the screen will return to the
Main Screen.
To unlock the Remote Controller
Press any key.
(When the mode has been accepted, below screen will be displayed.)
Enter any 4 digits of number (if the number is
correct, the screen will be unlocked).
To reset forgotten password (under operation OFF screen)
Press
 ,
 and
 continuously for 5 seconds.
(When the mode has been accepted, below screen will be displayed.)
Select “Reset”.
(The screen will be off after 3 seconds.)
R/C Lock
 
23 
4.1.4  Menus For user 
 
Select menus and determine settings according to the system
available in the household. All initial settings must be done by an
authorised dealer or a specialist. It is recommended that all alterations
of the initial settings are also done by an authorised dealer or a
specialist.
• After initial installation, you may manually adjust the settings.
• The initial setting remains active until the user changes it.
• The Remote Controller can be used for multiple installations.
• Ensure the operation indicator is OFF before setting.
• The system may not work properly if set wrongly.
Please consult an authorised dealer.
To display <Main Menu>:
To select menu:
To confirm the selected content:
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
1 Function setup
1.1
Weekly timer
Once the weekly timer is set
up, User can edit from Quick
Menu.
To set up to 6 patterns of
operation on a weekly basis.
• Disabled if Heat-Cool SW is
pressed or if Force Heater
is on.
Timer setup
Select day of the week and
set the patterns needed
(Time / Operation ON/OFF / Mode)
Timer copy
Select day of the week
 
 
24 
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
1.2
 Holiday timer
To save energy, a holiday
period may be set to either turn
OFF the system or lower the
temperature during the period.
OFF
 ON
Holiday start and end.
Date and time
OFF or lowered temperature
• Weekly timer setting may be temporarily disabled during Holiday timer setting
but it will be restored once the Holiday timer is completed.
1.3
 Quiet timer
To operate quietly during the
preset period.
6 patterns may be set.
Level 0 means the mode is off.
Time to start Quiet :
Date and time
Level of quietness:
0 ~ 3
1.4
 Room heater
To set the room heater ON
or OFF.
OFF
1.5
 Tank heater
To set the tank heater ON or
OFF.
OFF
• Available only if connected to the tank.
1.6
 Sterilization
To set the auto sterilization ON
or OFF.
OFF
• Available only if connected to the tank.
• Do not use the system during sterilization in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilization function field settings according to the local laws and
regulations.
2 System check
2.1
 Energy monitor
Present or historical chart
of energy consumption,
generation or COP.
Present
Select and retrieve
Historical chart
Select and retrieve
• COP= Coefficient of Performance.
• For historical chart, the period is selected from 1 day/1 week/1year.
• Energy consumption (kWh) of heating,    cooling, tank and total may be retrieved.
• The total power consumption is an estimated value based on AC 230 V and may
differ from value measured by precise equipment.
2.2
 Water temperatures
Shows all water temperatures
in each area.
Actual water temperature of 8 items:
Inlet / Outlet / Zone 1 / Zone 2 / Tank / Buffer
tank / Solar / Pool
Select and retrieve
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service p
artners.
*2  Only displayed when COOL mode is unlocked (This means when COOL mode is available).
 *
1
 
 
Page of 127
Display

Click on the first or last page to see other WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 service manuals if exist.