DOWNLOAD Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual ↓ Size: 15.68 MB | Pages: 127 in PDF or view online for FREE

Model
WH-SXC09H3E5 WH-SXC12H6E5 WH-UX09HE5 WH-UX12HE5
Pages
127
Size
15.68 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR-TO-WATER HEATPUMP
File
wh-sxc09h3e5-wh-sxc12h6e5-wh-ux09he5-wh-ux12he5.pdf
Date

Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual ▷ View online

37 
4.1.6 Main 
Components 
 
Cabinet front plate
Cabinet front plate (2 pieces)
Remote controller
PCB
Single Phase RCCB/ELCB (Main Power)
Single Phase RCCB/ELCB (Backup Heater)
Control board cover
Control board
Flow sensor
Air purge valve
Backup heater
Overload protector (2 pieces for SXC09*3E5
or 3 pieces for SXC12*6E5)
Expansion vessel
Pressure relief valve
Water pressure gauge
Water filter
Water pump
1
3
2
4
5-1
5-2
6
7
13
14
12
10
11
8
9
15
16
1
2
3
4
6
7
8
5-2
5-1
9
10
11
12
13
14
15
16
 
38 
4.2 Outdoor 
Unit 
Air inlet (rear)
Air outlet
Air inlet (side)
 
39 
5. Dimensions 
5.1 Indoor 
Unit 
 
Relative position between the indoor unit and the installation plate <Front View>
Unit: mm
340
500
58.9
141.9
100
88
.3
30
.6
49
12
9.
5
25
0
156
980
892
326.9
476
424.5
404.1
437.3
360
180
54.6
69.5
56.
1
51.
5
339.
3
45
<Top View>
<Front View>
<Side View>
<Bottom View>
≥1556 from
5
5
200
75
6
160
70
Indoor Unit
body
ground
Installation
plate
Installation
plate
Bolt -
size M8
Wall
Wall
More than 375
More than 375
 
40 
5.2 Outdoor 
Unit 
 
Unit: mm
<Top View>
<Front View>
<Side View>
900
400
320
355
900
318.5
253
218
165
243
1340
615
320
40
40
20
110
356.
5
<Side view>
<Back view>
30
 
 
Page of 127
Display

Click on the first or last page to see other WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 service manuals if exist.