10.2 Outdoor Unit 
10.2.1  Main Printed Circuit Board 
 
 CN-HT1
 CN-HT2
 CN-HOT
 CN-HPS
 CN-TH3
 CN-DIS
 CN-RY1
 CN-PSW1
 CN-V1
CN-EV2
CN-TH2
CN-FM1
CN-FM2
CN-TH1 CN-EV
 
 
 
 
54 
10.2.2  Noise Filter Printed Circuit Board 
 
CN-BLK
CN-WHT
AC-BLK
FG1
FG2
CN-ACL
CN-ACN
 
10.2.3  Capacitor Printed Board 
 
DCP-IN
DCN-OUT
DCN-IN
FG201
AC-C
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
55 
11. Installation 
Instruction 
11.1 Indoor Unit 
11.1.1  Select the Best Location 
  There should not be any heat source or steam 
near the unit. 
  A place where air circulation in the room is good. 
  A place where drainage can be easily done. 
  A place where noise prevention is taken into 
consideration. 
  Do not install the unit near the door way. 
  Ensure the spaces indicated by arrows from the 
wall, ceiling, fence or other obstacles. 
  Recommended installation height for indoor unit 
shall be at least 800 mm. 
  Must install on a vertical wall. 
  When install electrical equipment at wooden 
building of metal lath or wire lath, according to 
electrical facility technical standard, no electrical 
contact between equipment and building is 
allowed. Insulator must be installed in between. 
  Do not install the unit at outdoor. This is designed 
for indoor installation only. 
 
100 mm
or more
100 mm
or more
100 mm
or more
Required space for installation
 
11.1.2  How To Fix Installation Plate 
The mounting wall is strong and solid enough to 
prevent it from vibration. 
 
(Unit in mm)
5
5
200
756
160
70
Indoor Unit
body
≥1556 from
ground
Installation
plate 1
Installation
plate 4
Bolt -
size M8
Wall
Wall
More than 375 More than 375
 
The centre of installation plate should be at more than 
375 mm at right and left of the wall. 
The distance from installation plate edge to ground 
should more than 1556 mm. 
  Always mount the installation plate horizontally 
plate by aligning the marking thread and using a 
level gauge. 
  Mount the installation plate on the wall with 6 sets 
of plug, bolt and washer (all non-supply) with size 
M8. 
11.1.3  To Drill A Hole In The Wall And 
Install A Sleeve Of Piping 
1.  Insert the piping sleeve to the hole. 
2.  Fix the bushing to the sleeve. 
3.  Cut the sleeve until it extrudes about 15 mm 
from the wall. 
 
 
CAUTION
 
 
When the wall is hollow, please be sure to use the sleeve 
for tube assembly to prevent dangers caused by mice 
biting the connection cable. 
 
4.  Finish by sealing the sleeve with putty or 
caulking compound at the final stage. 
 
15 mm
Putty or caulking compound
ø70 mm through hole
Indoor
Outdoor
Sleeve for tube
assembly
Approx. 5 - 7 mm
Bushing for tube assembly
Wall
 
11.1.4  Indoor Unit Installation 
11.1.4.1  Access to Internal Components 
 
 
WARNING
 
This section is for authorized and licensed electrician/water 
system installer only. Work behind the front plate secured by 
screws must only be carried out under supervision of qualified 
contractor, installation engineer or service person. 
 
Please follow the steps below for take out front plate. 
Before removing the front plate of indoor unit, always 
switch off all power supply (i.e. indoor unit power 
supply, heater power supply and Tank Unit power 
supply). 
1.  Remove the 2 mounting screws which located at 
bottom of the front plate. 
56 
2.  Gently pull the lower section of the front plate 
towards you to remove the front plate from left and 
right hooks. 
3.  Hold the left edge and right edge of front plate to 
lift up front plate from hooks. 
 
Hook
Lift up
Screws
 
11.1.4.2  Install the indoor unit 
1.  Engage the slots on the indoor unit to the hooks of 
installation plate 
1
. Ensure the hooks are properly 
seated on the installation plate by moving it left 
and right. 
2.  Fix the screws 
5
 to the holes on the hooks of 
installation plate 
4
, as illustrated below. 
 
Installation plate
Indoor unit back
Slots
Wall
Hooks
Installation plate
Screws
Note: Do not lift the
Indoor Unit by holding the
refrigerant and water pipes
to prevent damage of the
pipes.
1
4
5
 
11.1.4.3  Water Piping Installation 
  The minimum requirement of water in the system 
is 50 litres. If this value could not be achieved, 
please install additional buffer tank (field supply). 
  Water inlet and water outlet in indoor unit are used 
for connection to water circuit. Please request a 
licensed technician to install this water circuit. 
  This water circuit must comply with all relevant 
European and national regulations, i.e. IEC/EN 
61770. 
  Be careful not to deform the piping to excessive 
force when doing piping connection job. 
  Use Rp 1 ¼" nut for both water inlet and outlet 
connection and clean all pipings with tap water 
before connecting to the indoor unit. 
  Cover the pipe end to prevent dirt and dust when 
inserting it through a wall. 
  Choose proper sealer which can withstand the 
pressures and temperatures of the system. 
  If an existing tank is to be connected to this indoor 
unit, ensure the pipes are clean before water pipe 
installation is carried out. 
  Be sure to use two spanners to tighten the 
connection. Tighten the nuts with torque wrench: 
117.6N•m. 
 
Torque wrench
Indoor unit
Spanner
 
  If non-brass metallic piping is used for installation, 
make sure to insulate the pipes to prevent 
galvanic corrosion. 
  Make sure to insulate the water circuit pipes to 
prevent reduction of heating capacity. 
  After installation, check the water leakage 
condition in connection area during test run. 
 
Water Inlet
Water Outlet
 
 
 
CAUTION
 
Do not over tighten, over tightening cause water leakage. 
11.1.4.4  Refrigerant Pipe Installation 
1  Please make flare after inserting flare nut (located 
at joint portion of tube assembly) onto the copper 
pipe. (In case of using long piping) 
2  Do not use pipe wrench to open refrigerant piping. 
Flare nut may be broken and cause leakage. Use 
proper spanner or ring wrench. 
3  Connect the piping: 
  Align the center of piping and sufficiently 
tighten the flare nut with fingers. 
  Be sure to use two spanners to tighten the 
connection. 
Further tighten the flare nut with torque 
wrench in specified torque as stated in the 
table. 