11. Installation
Instruction
11.1 Indoor Unit
11.1.1 Select the Best Location
There should not be any heat source or steam
near the unit.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 800 mm.
Must install on a vertical wall.
When install electrical equipment at wooden
building of metal lath or wire lath, according to
electrical facility technical standard, no electrical
contact between equipment and building is
allowed. Insulator must be installed in between.
electrical facility technical standard, no electrical
contact between equipment and building is
allowed. Insulator must be installed in between.
Do not install the unit at outdoor. This is designed
for indoor installation only.
100 mm
or more
100 mm
or more
100 mm
or more
Required space for installation
11.1.2 How To Fix Installation Plate
The mounting wall is strong and solid enough to
prevent it from vibration.
prevent it from vibration.
(Unit in mm)
5
5
200
756
160
70
Indoor Unit
body
body
≥1556 from
ground
ground
Installation
plate 1
plate 1
Installation
plate 4
plate 4
Bolt -
size M8
size M8
Wall
Wall
More than 375 More than 375
The centre of installation plate should be at more than
375 mm at right and left of the wall.
The distance from installation plate edge to ground
should more than 1556 mm.
375 mm at right and left of the wall.
The distance from installation plate edge to ground
should more than 1556 mm.
Always mount the installation plate horizontally
plate by aligning the marking thread and using a
level gauge.
level gauge.
Mount the installation plate on the wall with 6 sets
of plug, bolt and washer (all non-supply) with size
M8.
M8.
11.1.3 To Drill A Hole In The Wall And
Install A Sleeve Of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm
from the wall.
CAUTION
When the wall is hollow, please be sure to use the sleeve
for tube assembly to prevent dangers caused by mice
biting the connection cable.
for tube assembly to prevent dangers caused by mice
biting the connection cable.
4. Finish by sealing the sleeve with putty or
caulking compound at the final stage.
15 mm
Putty or caulking compound
ø70 mm through hole
Indoor
Outdoor
Sleeve for tube
assembly
Approx. 5 - 7 mm
Bushing for tube assembly
Wall
11.1.4 Indoor Unit Installation
11.1.4.1 Access to Internal Components
WARNING
This section is for authorized and licensed electrician/water
system installer only. Work behind the front plate secured by
screws must only be carried out under supervision of qualified
contractor, installation engineer or service person.
system installer only. Work behind the front plate secured by
screws must only be carried out under supervision of qualified
contractor, installation engineer or service person.
Please follow the steps below for take out front plate.
Before removing the front plate of indoor unit, always
switch off all power supply (i.e. indoor unit power
supply, heater power supply and Tank Unit power
supply).
1. Remove the 2 mounting screws which located at
bottom of the front plate.
56
2. Gently pull the lower section of the front plate
towards you to remove the front plate from left and
right hooks.
right hooks.
3. Hold the left edge and right edge of front plate to
lift up front plate from hooks.
Hook
Lift up
Screws
11.1.4.2 Install the indoor unit
1. Engage the slots on the indoor unit to the hooks of
installation plate
1
. Ensure the hooks are properly
seated on the installation plate by moving it left
and right.
and right.
2. Fix the screws
5
to the holes on the hooks of
installation plate
4
, as illustrated below.
Installation plate
Indoor unit back
Slots
Wall
Hooks
Installation plate
Screws
Note: Do not lift the
Indoor Unit by holding the
refrigerant and water pipes
to prevent damage of the
pipes.
1
4
5
11.1.4.3 Water Piping Installation
The minimum requirement of water in the system
is 50 litres. If this value could not be achieved,
please install additional buffer tank (field supply).
please install additional buffer tank (field supply).
Water inlet and water outlet in indoor unit are used
for connection to water circuit. Please request a
licensed technician to install this water circuit.
licensed technician to install this water circuit.
This water circuit must comply with all relevant
European and national regulations, i.e. IEC/EN
61770.
61770.
Be careful not to deform the piping to excessive
force when doing piping connection job.
Use Rp 1 ¼" nut for both water inlet and outlet
connection and clean all pipings with tap water
before connecting to the indoor unit.
before connecting to the indoor unit.
Cover the pipe end to prevent dirt and dust when
inserting it through a wall.
Choose proper sealer which can withstand the
pressures and temperatures of the system.
If an existing tank is to be connected to this indoor
unit, ensure the pipes are clean before water pipe
installation is carried out.
installation is carried out.
Be sure to use two spanners to tighten the
connection. Tighten the nuts with torque wrench:
117.6N•m.
117.6N•m.
Torque wrench
Indoor unit
Spanner
If non-brass metallic piping is used for installation,
make sure to insulate the pipes to prevent
galvanic corrosion.
galvanic corrosion.
Make sure to insulate the water circuit pipes to
prevent reduction of heating capacity.
After installation, check the water leakage
condition in connection area during test run.
Water Inlet
Water Outlet
CAUTION
Do not over tighten, over tightening cause water leakage.
11.1.4.4 Refrigerant Pipe Installation
1 Please make flare after inserting flare nut (located
at joint portion of tube assembly) onto the copper
pipe. (In case of using long piping)
pipe. (In case of using long piping)
2 Do not use pipe wrench to open refrigerant piping.
Flare nut may be broken and cause leakage. Use
proper spanner or ring wrench.
proper spanner or ring wrench.
3 Connect the piping:
Align the center of piping and sufficiently
tighten the flare nut with fingers.
Be sure to use two spanners to tighten the
connection.
Further tighten the flare nut with torque
wrench in specified torque as stated in the
table.
Further tighten the flare nut with torque
wrench in specified torque as stated in the
table.
Click on the first or last page to see other WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 service manuals if exist.