Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ▷ View online
21
Indoor Unit
S-45YA1E5
S-56YA1E5
Panel CZ-KPY1
Wired CZ-RT1
Remote Control
Wireless
CZ-RWS1 (Heat-pump models)
CZ-RWC1 (Cooling models)
Performance Test Condition
ISO5151
Phase 1
1
V 220/230/240 220/230/240
Power Supply
Hz 50
50
kW 4.50
5.60
Capacity
BTU/h 15400
19100
Running Current
A
0.35
0.35
Input Power
W
40
45
dB-A (H / L)
39 / 35
40 / 36
Cooling
Noise level
Power level dB (H / L)
54 / 50
55 / 51
kW 5.10
6.40
Capacity
BTU/h 17400
21800
Running Current
A
0.35
0.35
Input Power
W
40
45
dB-A (H / L)
39 / 35
40 / 36
Heating
Noise level
Power level dB (H / L)
54 / 50
55 / 51
External Static Pressure
Pa
-
-
Max Current
A
0.40
0.40
Max Input Power
W
50
55
Type
Turbo Fan
Turbo Fan
Material
ABS + GF 10%
ABS + GF 10%
Motor type
DC (8-Poles)
DC (8-Poles)
Input power
W
-
-
Output power
W
40
40
Cool r.p.m.
450
490
Lo
Heat r.p.m.
560
580
Cool r.p.m.
540
580
Me
Heat r.p.m.
605
625
Cool r.p.m.
620
660
Indoor Fan
Speed
Hi
Heat r.p.m.
650
670
Moisture Removal
L/h (Pt/h)
2.5 (5.3)
3.2 (6.7)
Cool m
3
/min (ft
3
/min)
6.5 (229)
7.2 (254)
Lo
Heat m
3
/min (ft
3
/min)
8.3 (293)
8.6 (303)
Cool m
3
/min (ft
3
/min)
7.9 (279)
8.6 (303)
Me
Heat m
3
/min (ft
3
/min)
9.0 (318)
9.4 (331)
Cool m
3
/min (ft
3
/min)
9.3 (326)
9.9 (349)
Indoor Airflow
Hi
Heat m
3
/min (ft
3
/min)
10.3 (364)
10.6 (374)
Refrigeration Cycle
Control Device
Expansion Valve
Expansion Valve
Height
mm (inch)
260 (10-1/4)
260 (10-1/4)
Width
mm (inch)
575 (22-21/32)
575 (22-21/32)
Dimension
Depth
mm (inch)
575 (22-21/32)
575 (22-21/32)
Net weight
kg (lbs)
18 (40)
18 (40)
Gas side
mm (inch)
12.70 (1/2)
12.70 (1/2)
Diameter
Liquid side
mm (inch)
6.35 (1/4)
6.35 (1/4)
Piping
Max Length
m (ft)
15.0 (49.20)
15.0 (49.20)
22
External diameter
mm
36
36
Drain hose
Length mm
193
193
Fin material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
Indoor Heat
Exchanger
Size (W x H x L)
mm
1285 x 210 x 12.7
1225 x 210 x 12.7
1225 x 210 x 12.7
1285 x 210 x 12.7
1225 x 210 x 12.7
1225 x 210 x 12.7
Material
Air Filter
Type
Power Supply
Indoor Power Supply
Indoor Power Supply
Length m
(ft)
-
-
Power cord
Core x Diameter
mm
2
-
-
Thermostat
Electronic Control
Electronic Control
Maximum °C
32
32
Cool
Minimum °C
21
21
Maximum °C
27
27
Indoor Operation
Range
Heat
Minimum °C
16
16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68.0°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for future improvement.
23
3.3 95 x 95 Cassette Type Indoor Unit – UA1E5 Series
Indoor Unit
S-63UA1E5
S-71UA1E5
S-90UA1E5
Panel CZ-BT03P
Wired CZ-RT1
Remote Control
Wireless
CZ-RWS1 (Heat-pump models)
CZ-RWC1 (Cooling models)
Performance Test Condition
ISO 5151
Phase 1 1
1
V
220 230 240 220 230 240 220 230 240
Power Supply
Hz 50 50 50
kW 6.30
7.10 9.00
Capacity
BTU/h 21500 24200 30700
Running
Current
A
0.45 0.50 0.55 0.50 0.55 0.60 0.50 0.55 0.60
Input
Power
W
105 110 115 110 115 120 110 115 120
dB-A (H / L)
41 / 35
41 / 36
42 / 36
42/37
42 / 36
42/37
Cooling
Noise level
Power level dB (H / L)
56 / 50
56 / 51
57 / 51
57/52
57 / 51
57/52
kW 7.10 8.00
10.00
Capacity
BTU/h 24200 27300 34100
Running
Current
A
0.45 0.50 0.55 0.50 0.55 0.60 0.50 0.55 0.60
Input
Power
W
105 110 115 110 115 120 110 115 120
dB-A (H / L)
41 / 35
41 / 36
42 / 36
42/37
42 / 36
42/37
Heating
Noise level
Power level dB (H / L)
56 / 50
56 / 51
57 / 51
57/52
57 / 51
57/52
External Static Pressure
Pa
-
-
-
Max
Current
A
0.55 0.60 0.65 0.61 0.66 0.71 0.61 0.66 0.71
Max
Input
Power
W
110 120 130 121 131 141 121 131 141
Type
Turbo Fan
Turbo Fan
Turbo Fan
Material
ABS + GF 10%
ABS + GF 10%
ABS + GF 10%
Motor type
AC (3 Speeds, 6 Poles) AC (3 Speeds, 6 Poles)
AC (3 Speeds, 6 Poles)
Input power
W
-
-
-
Output power
W
35
35
35
Cool
r.p.m.
370 390 410 400 420 430 400 420 430
Lo
Heat
r.p.m.
370 390 410 400 420 430 400 420 430
Cool
r.p.m.
430 450 470 460 480 490 460 480 490
Me
Heat
r.p.m.
430 450 470 460 480 490 460 480 490
Cool
r.p.m.
470 490 510 500 520 530 500 520 530
Indoor Fan
Speed
Hi
Heat
r.p.m.
470 490 510 500 520 530 500 520 530
Moisture Removal
L/h (Pt/h)
3.6 (7.6)
4.6 (8.8)
5.4 (11.3)
Cool m
3
/min (ft
3
/min)
17 (600)
18 (635)
18 (635)
Lo
Heat m
3
/min (ft
3
/min)
17 (600)
18 (635)
18 (635)
Cool m
3
/min (ft
3
/min)
19 (671)
20 (706)
20 (706)
Me
Heat m
3
/min (ft
3
/min)
19 (671)
20 (706)
20 (706)
Cool m
3
/min (ft
3
/min)
21 (741)
22 (777)
22 (777)
Indoor Airflow
Hi
Heat m
3
/min (ft
3
/min)
21 (741)
22 (777)
22 (777)
Refrigeration Cycle
Control Device
Expansion Valve
Expansion Valve
Expansion Valve
Height
mm (inch)
246 (9-11/16)
246 (9-11/16)
246 (9-11/16)
Width
mm (inch)
840 (33-1/16)
840 (33-1/16)
840 (33-1/16)
Dimension
Depth
mm (inch)
840 (33-1/16)
840 (33-1/16)
840 (33-1/16)
Net weight
kg (lbs)
26 (57)
26 (57)
26 (57)
24
Gas side
mm (inch)
12.70 (1/2)
15.88 (5/8)
15.88 (5/8)
Diameter
Liquid side
mm (inch)
6.35 (1/4)
9.52 (3/8)
9.52 (3/8)
Piping
Max Length
m (ft)
15.0 (49.20)
15.0 (49.20)
15.0 (49.20)
External diameter
mm
36
36
36
Drain hose
Length
mm 193 193 193
Fin material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 10 x 19
2 x 10 x 21
2 x 10 x 21
Indoor Heat
Exchanger
Size (W x H x L)
mm
2100 x 210 x 12.7
2040 x 210 x 12.7
2040 x 210 x 12.7
2100 x 210 x 12.7
2040 x 210 x 12.7
2100 x 210 x 12.7
2040 x 210 x 12.7
Material
PP
PP
PP
Air Filter
Type
Power Supply
Indoor Power Supply
Indoor Power Supply
Indoor Power Supply
Length m
(ft)
-
-
-
Power cord
Core x Diameter
mm
2
- -
-
Thermostat
Electronic Control
Electronic Control
Electronic Control
Maximum °C
32
32
32
Cool
Minimum °C
21
21
21
Maximum °C
27
27
27
Indoor Operation
Range
Heat
Minimum °C
16
16
16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68.0°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for future improvement.
Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.