DOWNLOAD Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ↓ Size: 16.42 MB | Pages: 127 in PDF or view online for FREE

Model
S-22KA1E5 S-28KA1E5 S-36KA1E5 S-45KA1E5 S-56KA1E5 S-63KA1E5 S-71KA1E5 S-22YA1E5 S-28YA1E5 S-36YA1E5 S-45YA1E5 S-56YA1E5 S-22NA1E5 S-28NA1E5 S-32NA1E5 S-36NA1E5 S-45NA1E5 S-56NA1E5 S-45MA1E5 S-56MA1E5 S-63MA1E5 S-7
Pages
127
Size
16.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
s-22ka1e5-s-28ka1e5-s-36ka1e5-s-45ka1e5-s-56ka1e5-.pdf
Date

Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual ▷ View online

Interface Module for External Control / Integration 
CZ-CAP1 
x Demand 
Control 
With Demand Control, it is possible to limit maximum electrical current to air conditioner. This usually 
used to integrate with central control system, building automation system or etc. 
 
 
From external device, it is required to use a volt free 
contact (relay) for integration.  
(DC24V 2mA, wire length max 150m) 
 
COM shorted with 
Max rated current 
LV1 70% 
LV2 40% 
LV3 0% 
 
x Forced 
Stop 
o  With the Forced Stop input, it is possible to override the air conditioning operation to force stop if signal is 
received from a fire alarm system, BAS or etc. 
 
 
From external device, it is required to use a volt free 
contact (relay) for integration.  
(DC24V 2mA, wire length max 150m) 
 
When contact closed, AC will forced 
and continue stop operation. 
 
When contact opened, AC will switch to standby condition.  
 
LED display on PCB 
2 3 4 5 6 7 8 9 
Ɉ 
Ɉ 
Ɉ 
Ɉ 
Ɉ 
Ɉ 
Ɉ 
Ɉ 
10 
x  Heat / Cool Mode selection 
o  Must use together with Cooling / Heating Selector Switch (CZ-RD1) 
o  With the heat cool selector switch, operation mode (Heat / Cool / Fan) can be set & fixed by higher 
authority user. 
o  If OFF selected, Unit will operate freely base on remote setting. 
o  If ON & FAN selected, Unit will in priority to operate fan mode only. 
o  If ON & MODE & HEAT selected, unit will in priority to operate heat mode only. 
o  Priority mode is indicated in wired remote.  If remote setting is not same mode with Priority Mode, indoor 
unit will standby until priority mode canceled. (power led blinks ON 2.5sec; OFF 0.5sec) 
 
 
 
x  Share External Signals to Next Outdoor Unit 
o  The Cooling / Heating Selector and Forced Stop input signals can be share with next outdoor systems. 
o  Maximum 30 outdoor units can share these signals.  
o  Wire requirement : 0.5mmƳ diameter and maximum length is 100m. 
o  Demand control signal cannot be shared to the next system. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11 
Group control equipment 
Wired 
Remote 
Control 
Group Control by one remote 
control 
x  All air conditioner units are 
controlled as a whole by the 
remote control. 
x  All indoor units operate in the 
same mode. 
 
Indoor units
Remote-side
remote control
 
 
Remote side 
x  Optional wired remote 
control. 
 
Local Side 
x Not required. 
 
Twin remote control separate 
control 
x  Each indoor unit can be 
operated by either one of the two 
remote controls. 
x  Apart from timer setting time, 
displays for two remote controls 
are identical. 
x  Last pressed button has priority 
(main or slave is set at remote 
control). 
 
Indoor
units
Remote-side
remote control
Local-side
remote control
 
 
Remote side 
x  Optional wired remote control
 
Local side 
x  Optional wired remote control
Common 
control 
Common control / group 
x  Operation is possible using 
either wired or wireless remote 
control unit. 
x  Last pressed button has priority. 
 
Wire remote
control
Receptor unit
Wireless
remote
control
 
 
x  Optional wired remote control 
and wireless remote control. 
 
Centralized control system possibility (for Europe market only) 
Centralized Control 
(UM NET) 
 
 
 
Urban Controller 
 
 
 
BMS RS232C 
Serial Connection 
 
 
 
12 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.