18.4.15  H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) 
Malfunction Decision Conditions 
  During startup and operation of cooling and heating, the temperatures detected by the outdoor liquid pipe 
temperature sensor are used to determine sensor errors. 
 
Malfunction Caused 
 Faulty 
connector 
connection. 
 Faulty 
sensor. 
 Faulty 
PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
110 
18.4.16  H97 (Outdoor Fan Motor – DC Motor Mechanism Locked) 
Malfunction Decision Conditions 
  The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor. 
 
Malfunction Caused 
  Operation stops due to short circuit inside the fan motor winding. 
  Operation stops due to breaking of wire inside the fan motor. 
  Operation stops due to breaking of fan motor lead wires. 
  Operation stops due to Hall IC malfunction. 
  Operation error due to faulty outdoor unit PCB. 
 
 
Troubleshooting 
 
FAN MOTOR
CN-MTR2 
(WHT)
10
W
MS 
U
5
V
14
16
IC19
CN-MTR1
1
2
R105
1k
3
4
5
5V
R111
R120 
1k
1k
+
C173
C175 
0.01μ
50V
G5
G5
G5
C177
C176
0.01μ 
0.01μ
50V 
50V
G5
PCB BOARD
Replace fan motor.
Replace outdoor PCB.
Replace fan motor.
Replace fan motor.
Replace outdoor PCB.
Does it rotate?
Is the resistance normal?
Use an inverter check to check on 
the power transistor on board.
Connect it to PCB’s CN-MRT2 port. 
Turn power ON and run the unit.
Do all 6 LED light turn ON and turn 
OFF periodically?
Does the voltage at each terminal 
becomes 5 and 0Vdc repeatedly?
U
NO
YES
V
W
NO
YES
NO
YES 
NO
YES
When abnormality indication starts again
Turn off power supply and rotate fan by 
hand.
Caution
For safety reason and to prevent 
component breakdown, always switch 
off the power before remove and 
connect the component.
Does fan rotate smoothly?
NO
Replace fan motor.
YES
Turn power supply on and operate fan.
Turn off power supply and 
disconnect fan motor CN-MRT2 
connector.
Check resistance of the motor. 
Measure at fan motor connector 
CN-MRT1 (1-2, 1-3, 2-3).
Stop the fan motor
Check the rotation feedback output from 
fan motor’s CN-MTR1 output.
Rotate the fan motor manually (by hand) 
while measure the voltage at PCB’s
CN-MRT1
- Between 1(+) and 5(-)
- Between 2(+) and 5(-)
- Between 3(+) and 5(-)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
111 
18.4.17  H98 (Error Code Stored in Memory and no alarm is triggered / no TIMER LED 
flashing) 
Malfunction Decision Conditions 
  Indoor high pressure is detected when indoor heat exchanger is detecting very high temperature when the unit is 
operating in heating operation. 
  Phenomena: unit is stopping and re-starting very often in heating mode 
 
Malfunction Caused 
  Indoor heat exchanger thermistor 
  Clogged air filter or heat exchanger 
  Over-bent pipe (liquid side) 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
112 
18.4.18  H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) 
Error Code will not display (no Timer LED blinking) but store in EEPROM 
 
Malfunction Decision Conditions 
  Freeze prevention control takes place (when indoor pipe temperature is lower than 2°C) 
 
Malfunction Caused 
  Air short circuit at indoor unit 
  Clogged indoor unit air filter 
  Dust accumulation on the indoor unit heat exchanger 
  2/3 way valve closed 
  Faulty indoor unit fan motor 
 Refrigerant 
shortage 
(refrigerant leakage) 
  Clogged expansion valve or strainer 
  Faulty indoor pipe temperature sensor 
  Faulty indoor unit PCB 
 