DOWNLOAD Panasonic CS-XE9DKE / CU-XE9DKE / CS-XE12DKE / CU-XE12DKE Service Manual ↓ Size: 16.28 MB | Pages: 108 in PDF or view online for FREE

Model
CS-XE9DKE CU-XE9DKE CS-XE12DKE CU-XE12DKE
Pages
108
Size
16.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-xe9dke-cu-xe9dke-cs-xe12dke-cu-xe12dke.pdf
Date

Panasonic CS-XE9DKE / CU-XE9DKE / CS-XE12DKE / CU-XE12DKE Service Manual ▷ View online

2.3. OUTDOOR UNIT
Outdoor Air Temperature
Control
Deice Operation
Low Operation Frequency
Protection Control
IPM (Power Transistor)
Overheating Protection Control
Compressor Overheating
Prevention Control
Total Running Current Control
Time Delay Safety Control
30 seconds Forced Operation
Overload Protection
5
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
3 Product Specifications
3.1. CS-XE9DKE CU-XE9DKE
Unit
CS-XE9DKE
CU-XE9DKE
Cooling Capacity
kW
kcal/h
BTU/h
2.6 (0.60 - 3.00)
2,240 (520 - 2,580)
8,870 (2,050 - 10,200)
Heating Capacity
kW
kcal/h
BTU/h
3.6 (0.60 - 5.00)
3,100 (520 - 4,300)
12,300 (2,050 - 17,100)
Moisture Removal
l/h
Pint/h
1.6
(3.4)
Power Source (Phase, Voltage, Cycle)
ø
V
Hz
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 6.5 (231)
Heating; 7.1 (249)
Me
m
3
/min (cfm)
Cooling; 8.1 (286)
Heating; 8.8 (312)
Hi
m
3
/min (cfm)
Cooling; 9.9 (350)
Cooling; 30.0 (1,060)
Heating; 10.6 (370)
dB (A)
Cooling; High 39, Low 26
Cooling; 46
Heating; High 40, Low 27
Heating; 47
Noise Level
Power level dB
Cooling; High 50
Cooling; High 59
Heating; High 51
Heating; High 60
Electrical Data
Input
W
Cooling; 700 (115 - 880)
Heating; 900 (110 - 1,400)
Running Current
A
Cooling; 3.3
Heating; 4.0
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.71(3.20), 12.7
COP
W/W (kcal/hw), BTU/hw
Heating; 4.00 (3.44), 13.7
Starting Current
A
4.00
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
6
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Unit
CS-XE9DKE
CU-XE9DKE
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
Drain
Hose
Inner diameter
mm
16
Length
m
0.65
Power Cord Length
Number of core-wire
2.1 m
3 core wires × 1.0 mm
2

Dimensions
Height
inch (mm)
10 - 26/32 (275)
21 - 9/32 (540)
Width
inch (mm)
31 - 15/32 (799)
30 - 23/32 (780)
Depth
inch (mm)
9 - 9/32 (236)
11 - 3/8 (289)
Net Weight
lb (kg)
22 (10.0)
84 (38)
Compressor
Type
Involute scroll
Motor
Type
Brushless (4-pole)
Rated
Output
W
700
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 20%
P.P
Motor
Type
Transistor (8-poles)
Induction (6-poles)
Input
W
61.3
Rate Output
W
30
25
Fan Speed
Lo (Cool/Heat)
rpm
800 / 840
Me (Cool/Heat)
rpm
1,000 / 1,040
Hi (Cool/Heat)
rpm
1,240 / 1,270
770
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
1 / 20
FPI
21
19
Size (W × H × L)
mm
610 × 315 × 25.4
732.1 × 508 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
RB68A (360)
Refrigerant (R410A)
g (oz)
840 (29.7)
Thermostat
Electronic Control
Protection Device
Electronic Control
Electronic Control
Length
mm
C1, C2 ; 1,100, C3 ; 440
Capillary Tube
Flow Rate
l/min
C1, C2 ; 5.0, C3 ; 18.6
Inner Diameter
mm
C1, C2 ; 1.2, C3 ; 1.7
Air Filter
Material
Style
P.P.
Honeycomb
Fan Motor Capacitor
µF, VAC
1.8 µF, 400 VAC
  • Specifications are subject to change without notice for further improvement.
7
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
3.2. CS-XE12DKE CU-XE12DKE
Unit
CS-XE12DKE
CU-XE12DKE
Cooling Capacity
kW
kcal/h
BTU/h
3.45 (0.60 - 4.00)
2,970 (520 - 3,440)
11,800 (2,050 - 13,600)
Heating Capacity
kW
kcal/h
BTU/h
4.80 (0.60 - 6.50)
4,130 (520 - 5,590)
16,400 (2,050 - 22,200)
Moisture Removal
l/h
Pint/h
2.0
(4.2)
Power Source (Phase, Voltage, Cycle)
ø
V
Hz
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 7.3 (258)
Heating; 9.2 (325)
Me
m
3
/min (cfm)
Cooling; 9.2 (323)
Heating; 10.3 (360)
Hi
m
3
/min (cfm)
Cooling; 10.9 (380)
Cooling; 31.0 (1,090)
Heating; 11.8 (420)
dB (A)
Cooling; High 42, Low 29
Cooling; 48
Heating; High 42, Low 33
Heating; 50
Noise Level
Power level dB
Cooling; High 53
Cooling; High 61
Heating; High 53
Heating; High 63
Electrical Data
Input
W
Cooling; 950 (120 - 1,280)
Heating; 1,260 (115 - 1,890)
Running Current
A
Cooling; 4.4
Heating; 5.6
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.63 (3.13), 12.4
COP
W/W (kcal/hw), BTU/hw
Heating; 3.81 (3.28), 13.0
Starting Current
A
5.60
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
8
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Page of 108