CompHz = Freq. A × Freq. H + Freq. C
Example Calculation:
Model No.: XE9DK
Operation Mode: Cooling
When Intake Air Temperature - Internal setting Temperature:
1.5°C
CompHz
=
Freq. A × Freq. H + Freq. C
=
1.9 × 20 + 1.0
=
39 Hz (It cuts down less than a decimal point)
Cooling & Soft Dry
XE9DK
XE12DK
Freq. A
Freq. C
Freq. A
Freq. C
Low Load (Freq. H
10)
0.9
11.0
0.9
11.0
High Load (Freq. H > 10)
1.9
1.0
1.9
0.7
Heating
XE9DK
XE12DK
Freq. A
Freq. C
Freq. A
Freq. C
Low Load (Freq. H
12)
1.4
10.6
1.4
10.6
High Load (Freq. H > 12)
2.2
1.0
2.1
1.8
Freq. Range
XE9DK
XE12DK
Cooling
Fc
39
52
Operation Range
12 ~ 86
12 ~ 102
Heating
Fh
56
69
Operation Range
14 ~ 128
14 ~ 128
8.1.2. Compressor Operation Frequency
Zone
Intake Air Temperature - Internal Setting Temperature (°C)
Freq. H
Cooling
Soft Dry
Heating
Cooling
Soft Dry
Heating
Remark
XE9DK XE12DK
XE9DK
XE12DK
XE9DK
XE12DK
1
-2.0
-3.0
1.0
2
1
5
5
1
1
2
-1.5
-2.5
0.5
2
5
10
10
3
8
3
-1.0
-2.0
0.0
4
8
10
10
6
13
4
-0.5
-1.5
-0.5
9
12
10
12
11
18
5
0.0
-1.0
-1.0
11
14
12
14
15
23
6
0.5
-0.5
-1.5
14
18
12
17
18
27
7
1.0
0.0
-2.0
17
22
14
17
21
30
8
1.5
0.5
-2.5
20
27
14
20
25
32
Fc, Fh
9
2.0
1.0
-3.0
20
27
16
24
25
32
Fc, Fh
10
2.5
1.5
-3.5
20
27
20
27
25
32
Fc, Fh
11
Nil
Nil
-4.0
Nil
Nil
Nil
Nil
25
32
Fh
12
Nil
Nil
-4.5
Nil
Nil
Nil
Nil
25
32
Fh
Operating Frequency Calculation Formula:
Remarks:
When Freq. H is equal to 20 (XE9DK), 27 (XE12DK) for cooling, 25 (XE9DK), 32 (XE12DK) for heating or above, the Comp.
may run at the freq. higher than Fc or Fh up to max. freq. operation.
Best Amenity Control
Every 90s (Cooling), 120s (Heating) maintain same zone Freq. H + 1 until Fc, Fh.
8.1.3. Cooling Operation
8.1.3.1. Thermostat control
  • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
17
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
8.1.4. Soft Dry Operation
8.1.4.1. Thermostat control
  • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.5°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
8.1.5. Heating Operation
8.1.5.1. Thermostat control
  • Compressor is OFF when Intake Air Temperature - Internal Setting +1.0°C.
  • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF
point.
8.1.6. 
Automatic Operation
This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air
temperature and outdoor air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to detect
the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.
18
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 30 minutes.
Remote Control Setting Temperature (°C)
T1
T2
T3
16 ~ 18
+10
+8
-5
19 ~ 22
+8
+7
-7
23 ~ 26
+7
+6
-7
27 ~ 30
+6
+5
-8
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
verse.
Operation Mode change from
Temperature shifts (°C)
Cooling/Soft Dry
→ Heating
-2
Heating
→ Cooling/Soft Dry
+2
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 + 6 = 31; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
  • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
O
O
O
O
O
Tab (rpm)
SHI
Hi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
XE9DK
1250
1200
1100
1000
900
800
780
730
720
XE12DK
1340
1310
1200
1090
980
880
780
730
720
[Heating]
Remote Control
O
O
O
O
O
Tab (rpm)
SSHI
SHi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
XE9DK
1350
1270
1160
1050
940
840
790
730
720
XE12DK
1490
1410
1330
1250
1170
1100
840
730
720
19
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
B. Indoor Fan Control
i. Indoor fan control operation outline
 1. Cooling / Dry / Fan / Ion / Oxygen
 2. Heating
20
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Page of 108
Display

Click on the first or last page to see other CS-XE9DKE / CU-XE9DKE / CS-XE12DKE / CU-XE12DKE service manuals if exist.