DOWNLOAD Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual ↓ Size: 12.33 MB | Pages: 127 in PDF or view online for FREE

Model
CS-VE9NKE CS-VE12NKE CU-VE9NKE CU-VE12NKE
Pages
127
Size
12.33 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-ve9nke-cs-ve12nke-cu-ve9nke-cu-ve12nke.pdf
Date

Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual ▷ View online

Indoor CS-VE12NKE 
Model 
Outdoor CU-VE12NKE 
Type  
Cross-flow 
fan 
Material  
AS+GF 
Resin 
Motor Type 
 
PWM (8-poles) 
Input Power 
28.5 
Output Power 
40 
Cool rpm 
660 
QLo 
Heat
rpm 750 
Cool rpm 
740 
Lo 
Heat
rpm 870 
Cool rpm 
1040 
Me 
Heat
rpm 1050 
Cool rpm 
1190 
Hi 
Heat
rpm 1140 
Cool rpm 
1270 
Indoor Fan 
Speed 
Shi 
Heat
rpm 1140 
Type 
 
Propeller Fan + Flat piece 
Material  
PP 
Motor Type 
 
DC Brushless (8-poles) 
Input Power 
kW 
57.29 
Output Power 
40 
Cool rpm 
960 
Outdoo
r Fa
Speed Hi 
Heat
rpm 
 
Moisture Removal 
L/h (Pt/h) 
2.0 (4.2) 
Cool m
3
/min (ft
3
/m) 4.3 
(152) 
QLo 
Heat m
3
/min (ft
3
/m) 5.4 
(191) 
Cool m
3
/min (ft
3
/m) 5.3 
(187) 
Lo 
Heat m
3
/min (ft
3
/m) 6.9 
(244) 
Cool m
3
/min (ft
3
/m) 9.0 
(318) 
Me 
Heat m
3
/min (ft
3
/m) 9.1 
(321) 
Cool m
3
/min (ft
3
/m) 10.9 
(384) 
Hi 
Heat m
3
/min (ft
3
/m) 10.3 
(362) 
Cool m
3
/min (ft
3
/m) 11.9 
(420) 
Indoor Airflow 
Shi 
Heat m
3
/min (ft
3
/m) 10.3 
(364) 
Cool m
3
/min (ft
3
/m) 
34.2 (1208) 
34.2 (1208) 
Outdoor Airflow 
Hi 
Heat m
3
/min (ft
3
/m) 
31.5 (1112) 
31.5 (1112) 
Control Device 
 
Expansion Valve 
Refrigerant Oil 
cm
3
 FV50S 
(450) 
Refrigeration 
Cycle 
Refrigerant Type
g (oz) 
R410A, 1.50k (52.9) 
Height(I/D / O/D)
mm (inch) 
295 (11-5/8) / 623 (24-1/2) 
Width (I/D / O/D)
mm (inch) 
890 (35) / 799 (31-1/2) 
Dimension 
Depth (I/D / O/D)
mm (inch) 
275 (10-7/8) / 299 (11-3/4) 
Weight 
Net (I/D / O/D) 
kg (lb) 
14.5 (32) / 43 (95) 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
5.0 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Piping 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
10 
Indoor CS-VE12NKE 
Model 
Outdoor CU-VE12NKE 
Inner Diameter 
mm  
16.7 
Drain Hose 
Length mm 
650 
Fin Material 
 
Aluminium (Pre Coat) 
Indoor Heat 
Exchanger 
FPI 
 
26.5 + 17 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row x Stage x FPI 
 
2 × 32 × 19.5  
Outdoor Heat 
Exchanger 
Size (W x H x D) 
mm 
871.6 × 586.24 × 37.8 
840.4 
Power Supply 
 
Indoor Power Supply 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
DRY BULB 
WET BULB 
Maximum 32 
23 
Cooling 
Minimum 16 
11 
Maximum 30 
 
Indoor Operation Range 
Heating 
Minimum 16 
 
Maximum 43 
26 
Cooling 
Minimum -10 
 
Maximum 24 
18 
Outdoor Operation Range 
Heating 
Minimum -20 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb  
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
11 
3. Features 
 
  Inverter Technology 
o  Wider output power range 
o Energy 
saving 
o Quick 
Cooling 
o Quick 
Heating 
o  More precise temperature control 
o  Deice with heating operation (Heat Charge system) 
 
  Environment Protection 
o  Non-ozone depletion substances refrigerant (R410A) 
 
  Long Installation Piping 
o  Long piping up to 15 meters during single split connection only 
 
  Easy to use remote control 
o  Press Individual operation button to ON 
o  Press OFF button to OFF 
 
  Quality Improvement 
o  Random auto restart after power failure for safety restart operation 
o Gas 
leakage 
protection 
o  Prevent compressor reverse cycle 
o  Inner protector to protect compressor 
o  Noise prevention during dry operation 
 
  Operation Improvement 
o  Quiet mode to reduce the indoor unit operating sound 
o  Powerful mode to reach the desired room temperature quickly 
o  24-hour timer setting 
o +8/10°C 
HEAT 
operation 
 
  Serviceability Improvement 
o  Breakdown Self Diagnosis function 
 
 
12 
4. Location of Controls and Components 
4.1 Indoor 
Unit 
 
4.2 Outdoor 
Unit 
 
4.3 Remote 
Control 
 
Page of 127
Display

Click on the first or last page to see other CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE service manuals if exist.