Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual ▷ View online
9
Indoor CS-VE12NKE
Model
Outdoor CU-VE12NKE
Type
Cross-flow
fan
Material
AS+GF
Resin
Motor Type
PWM (8-poles)
Input Power
W
28.5
Output Power
W
40
Cool rpm
660
QLo
Heat
rpm 750
Cool rpm
740
Lo
Heat
rpm 870
Cool rpm
1040
Me
Heat
rpm 1050
Cool rpm
1190
Hi
Heat
rpm 1140
Cool rpm
1270
Indoor Fan
Speed
Shi
Heat
rpm 1140
Type
Propeller Fan + Flat piece
Material
PP
Motor Type
DC Brushless (8-poles)
Input Power
kW
57.29
Output Power
W
40
Cool rpm
960
Outdoo
r Fa
n
Speed Hi
Heat
rpm
—
Moisture Removal
L/h (Pt/h)
2.0 (4.2)
Cool m
3
/min (ft
3
/m) 4.3
(152)
QLo
Heat m
3
/min (ft
3
/m) 5.4
(191)
Cool m
3
/min (ft
3
/m) 5.3
(187)
Lo
Heat m
3
/min (ft
3
/m) 6.9
(244)
Cool m
3
/min (ft
3
/m) 9.0
(318)
Me
Heat m
3
/min (ft
3
/m) 9.1
(321)
Cool m
3
/min (ft
3
/m) 10.9
(384)
Hi
Heat m
3
/min (ft
3
/m) 10.3
(362)
Cool m
3
/min (ft
3
/m) 11.9
(420)
Indoor Airflow
Shi
Heat m
3
/min (ft
3
/m) 10.3
(364)
Cool m
3
/min (ft
3
/m)
34.2 (1208)
34.2 (1208)
Outdoor Airflow
Hi
Heat m
3
/min (ft
3
/m)
31.5 (1112)
31.5 (1112)
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FV50S
(450)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 1.50k (52.9)
Height(I/D / O/D)
mm (inch)
295 (11-5/8) / 623 (24-1/2)
Width (I/D / O/D)
mm (inch)
890 (35) / 799 (31-1/2)
Dimension
Depth (I/D / O/D)
mm (inch)
275 (10-7/8) / 299 (11-3/4)
Weight
Net (I/D / O/D)
kg (lb)
14.5 (32) / 43 (95)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height different
m (ft)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
10
Indoor CS-VE12NKE
Model
Outdoor CU-VE12NKE
Inner Diameter
mm
16.7
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Indoor Heat
Exchanger
FPI
26.5 + 17
Fin Material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 × 32 × 19.5
Outdoor Heat
Exchanger
Size (W x H x D)
mm
871.6 × 586.24 × 37.8
840.4
840.4
Power Supply
Indoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
DRY BULB
WET BULB
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
—
Indoor Operation Range
Heating
Minimum 16
—
Maximum 43
26
Cooling
Minimum -10
—
Maximum 24
18
Outdoor Operation Range
Heating
Minimum -20
—
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
11
3. Features
Inverter Technology
o Wider output power range
o Energy
o Energy
saving
o Quick
Cooling
o Quick
Heating
o More precise temperature control
o Deice with heating operation (Heat Charge system)
o Deice with heating operation (Heat Charge system)
Environment Protection
o Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
o Long piping up to 15 meters during single split connection only
Easy to use remote control
o Press Individual operation button to ON
o Press OFF button to OFF
o Press OFF button to OFF
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during dry operation
o Inner protector to protect compressor
o Noise prevention during dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
o +8/10°C
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
o +8/10°C
HEAT
operation
Serviceability Improvement
o Breakdown Self Diagnosis function
12
4. Location of Controls and Components
4.1 Indoor
Unit
4.2 Outdoor
Unit
4.3 Remote
Control
Click on the first or last page to see other CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE service manuals if exist.