Diagnosis
display
Abnormality /
Protection control
Abnormality
Judgment
Protection
Operation
Problem Check
location
H41
Abnormal wiring or
piping connection
piping connection
— —
Wrong wiring and
connecting pipe, expansion
valve abnormality
connecting pipe, expansion
valve abnormality
Check indoor/outdoor
connection wire and connection
pipe
pipe
Expansion valve and lead wire
and connector
H59
ECONAVI sensor
abnormality
abnormality
Continuous for 25s
—
ECONAVI sensor open or
short circuit
short circuit
ECONAVI sensor (defective or
disconnected)
ECONAVI PCB
H64
Outdoor high
pressure sensor
abnormality
pressure sensor
abnormality
Continuous for 1
minutes
minutes
—
High pressure sensor open
circuit during compressor
stop
circuit during compressor
stop
High pressure sensor
Lead wire and connector
H67 Nanoe
abnormality
Nanoe stop for 5
minutes for 3 times
minutes for 3 times
— Nanoe
faulty
PCB
Nanoe system
Nanoe system
High voltage
H70
Light sensor
abnormality
abnormality
Continuous for 24
hours, 15 days
hours, 15 days
—
Light sensor open or short
circuit
circuit
Light sensor (defective or
disconnect)
H97
Outdoor fan motor
mechanism lock
mechanism lock
2 times happen
within 30 minutes
within 30 minutes
—
Outdoor fan motor lock or
feedback abnormal
feedback abnormal
Outdoor fan motor lead wire
and connector
Fan motor lock or block
H98
Indoor high pressure
protection
protection
— —
Indoor high pressure
protection (Heating)
protection (Heating)
Check indoor heat exchanger
Air filter dirty
Air circulation short circuit
Air circulation short circuit
H99
Indoor operating unit
freeze protection
freeze protection
— —
Indoor freeze protection
(Cooling)
(Cooling)
Check indoor heat exchanger
Air filter dirty
Air circulation short circuit
Air circulation short circuit
F11
4-way valve
switching
abnormality
switching
abnormality
4 times happen
within 30 minutes
within 30 minutes
—
4-way valve switching
abnormal
abnormal
4-way valve
Lead wire and connector
F17
Indoor standby units
freezing abnormality
freezing abnormality
3 times happen
within 40 minutes
within 40 minutes
—
Wrong wiring and
connecting pipe, expansion
valve leakage, indoor heat
exchanger sensor open
circuit
connecting pipe, expansion
valve leakage, indoor heat
exchanger sensor open
circuit
Check indoor/outdoor
connection wire and pipe
Indoor heat exchanger sensor
lead wire and connector
Expansion valve lead wire and
connector
F90
Power factor
correction
(PFC) circuit
protection
correction
(PFC) circuit
protection
4 times happen
within 10 minutes
within 10 minutes
—
Power factor correction
circuit abnormal
circuit abnormal
Outdoor PCB faulty
F91
Refrigeration cycle
abnormality
abnormality
2 times happen
within 20 minutes
within 20 minutes
—
Refrigeration cycle
abnormal
abnormal
Insufficient refrigerant or valve
close
F93
Compressor
abnormal revolution
abnormal revolution
4 times happen
within 20 minutes
within 20 minutes
—
Compressor abnormal
revolution
revolution
Power transistor module faulty
or compressor lock
F94
Compressor
discharge overshoot
protection
discharge overshoot
protection
4 times happen
within 30 minutes
within 30 minutes
—
Compressor discharge
pressure overshoot
pressure overshoot
Check refrigeration system
F95
Outdoor cooling high
pressure protection
pressure protection
4 times happen
within 20 minutes
within 20 minutes
—
Cooling high pressure
protection
protection
Check refrigeration system
Outdoor air circuit
F96
Power transistor
module overheating
protection
module overheating
protection
4 times happen
within 30 minutes
within 30 minutes
—
Power transistor module
overheat
overheat
PCB faulty
Outdoor air circuit (fan motor)
Outdoor air circuit (fan motor)
F97
Compressor
overheating
protection
overheating
protection
3 times happen
within 30 minutes
within 30 minutes
— Compressor
overheat
Insufficient refrigerant
F98
Total running current
protection
protection
3 times happen
within 20 minutes
within 20 minutes
— Total
current
protection
Check refrigeration system
Power source or compressor
Power source or compressor
lock
F99
Outdoor direct
current (DC) peak
detection
current (DC) peak
detection
Continuous
happen for 7 times
happen for 7 times
—
Power transistor module
current protection
current protection
Power transistor module faulty
or compressor lock
98
18.4 Self-diagnosis
Method
18.4.1 H11 (Indoor/Outdoor Abnormal Communication)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the data received from outdoor unit in indoor unit signal
transmission is checked whether it is normal.
Malfunction Caused
Faulty indoor unit PCB.
Faulty outdoor unit PCB.
Indoor unit-outdoor unit signal transmission error due to wiring error.
Indoor unit-outdoor unit signal transmission error due to breaking of wire in the connection wires between the
indoor and outdoor units.
Troubleshooting
YES
YES
YES
NO
When abnormality indication starts again
Measure the AC voltage at terminal 1 & 2 of outdoor unit
terminal board
terminal board
Is the measured voltage 230/240V?
●
AC power supply abnormal fluctuation
●
Defect in communication circuitry
●
Replace the PCB
of outdoor unit PCB
●
Improper connection at terminals
●
Check indoor/outdoor connecting cable
indoor/outdoor
●
Improper connection at terminals
●
Defect in receiver/transmitter module of
●
Replace the indoor unit PCB
●
Check indoor/outdoor connecting cable
indoor/outdoor
the communication circuitry in indoor
unit PCB
unit PCB
Measure the DC voltage at terminal 2 & 3 (communication
terminals) of outdoor unit terminal board
terminals) of outdoor unit terminal board
Is the measured DC voltage fluctuate between 10~70V?
Measure the AC voltage at terminal 1 & 2 of indoor unit
terminal board
terminal board
Is the measured voltage 230/240V?
YES
Measure the DC voltage at terminal 2 & 3 of indoor unit
terminal board
terminal board
Is the measured DC voltage fluctuate between 10~70V?
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
component breakdown, always switch
off the power before remove and
connect the component.
Caution
NO
NO
NO
99
18.4.2 H12 (Indoor/Outdoor Capacity Rank Mismatched)
Malfunction Decision Conditions
During startup, error code appears when different types of indoor and outdoor units are interconnected.
Malfunction Caused
Malfunction Caused
Wrong models interconnected.
Wrong indoor unit or outdoor unit PCBs mounted.
Indoor unit or outdoor unit PCBs defective.
Indoor-outdoor unit signal transmission error due to wrong wiring.
Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor
and outdoor units.
Troubleshooting
100
18.4.3 H14 (Indoor Intake Air Temperature Sensor Abnormality)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the temperatures detected by the indoor intake air
temperature sensor are used to determine sensor errors.
Malfunction Caused
Faulty
connector
connection.
Faulty
sensor.
Faulty
PCB.
Troubleshooting