Panasonic CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 Service Manual ▷ View online
17
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18PBE.
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
CONNECTABLE INDOOR UNIT CU-3E18PBE* CU-4E23PBE*
CU-4E27PBE*
CU-5E34PBE*
ROOM
A B C A B C D A B C D A B C D E
Wall
2.0kW CS-TZ20TKEW-1 ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
2.5kW CS-TZ25TKEW-1 ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.5kW CS-TZ35TKEW-1 ●
● – ●
●
● – ●
●
● – ●
●
●
●
●
4.2kW CS-TZ42TKEW-1 ●
● – ●
● – – ●
●
● – ●
●
●
● –
Capacity range of connectable units From 4.5kW to 9.0kW From 4.5kW to 11.0kW
From 4.5kW to 13.6kW
From 4.5kW to 17.5kW
Pipe length
1 room maximum pipe length (m)
25
25
25
25
Allowable elevation (m)
15
15
15
15
Total allowable pipe length (m)
50
60
70
80
Total pipe length for maximum
chargeless length (m)
30 30 45
45
Additional gas amount over
chargeless length (g/m)
20 20 20
20
Note: “●” : Available
Remarks for CU-3E18PBE / CU-4E23PBE / CU-4E27PBE / CU-5E34PBE
1.
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-TZ25TKEW-1 only. (Total nominal cooling capacity is 5.0kW)
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-TZ25TKEW-1 only. (Total nominal cooling capacity is 5.0kW)
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas.
18
4. Features
Inverter Technology
o Wider output power range
o Energy
o Energy
saving
o Quick
Cooling
o Quick
Heating
o More precise temperature control
Environment Protection
o Non-ozone depletion substances refrigerant (R32)
Long Installation Piping
o Long piping up to 15 meters during single split connection only
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during soft dry operation
o Inner protector to protect compressor
o Noise prevention during soft dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
Serviceability Feature
o Breakdown Self Diagnosis function
19
5. Location of Controls and Components
5.1 Indoor
Unit
Aluminium Fin
Auto OFF/ON button
• Use when remote control is misplaced
or malfunction occurs.
Air Filters
Front panel
Remote Control
receiver
receiver
Vertical Airflow
direction louver
• Do not adjust by hand.
direction louver
• Do not adjust by hand.
Horizontal Airflow
direction louver
• Manually adjustable.
direction louver
• Manually adjustable.
INDICATOR
TIMER
POWER
Air Purifying Filter
5.2 Outdoor
Unit
5.3 Remote
Control
Timer setting
Airflow direction
selection
selection
Fan speed selection
Transmitter
Operation mode
Sleep mode operation
Powerful/Quiet
operation
Remote control
display
Clock setting
OFF/ON
Check
Temperature setting
20
6. Dimensions
6.1 Indoor
Unit
16.4
264.6
Unit: mm
B
A
C
PIPE
HOLE
CENTER
HOLE
CENTER
PIPE
HOLE
CENTER
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
496.6
128
184
222
128
Right
piping
hole
piping
hole
Left
piping
hole
piping
hole
Installation
plate
plate
Indoor unit
external
dimensions
line
external
dimensions
line
420
380
45
95
<Top View>
<Front View>
<Bottom View>
<Rear View>
Relative position between the indoor unit and the installation plate <Front View>
<Side View>
<Side View>
87
64
22
<Remote Control Holder>
<Remote Control>
144.5
59
799
92.8
60
60
55
410
41-61
Gas side
Liquid side
Air intake
direction
direction
Air outlet
direction
direction
Left piping
hole
hole
290
197
Right piping
hole
hole
60
41
Click on the first or last page to see other CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 service manuals if exist.