DOWNLOAD Panasonic CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 Service Manual ↓ Size: 17.76 MB | Pages: 127 in PDF or view online for FREE

Model
CS-TZ20TKEW-1 CS-TZ25TKEW-1 CS-TZ35TKEW-1 CU-TZ20TKE-1 CU-TZ25TKE-1 CU-TZ35TKE-1
Pages
127
Size
17.76 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-tz20tkew-1-cs-tz25tkew-1-cs-tz35tkew-1-cu-tz20t.pdf
Date

Panasonic CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 Service Manual ▷ View online

13 
Indoor 
Model CS-TZ35TKEW-1 
POS (EAN) 
5025232874620 
Outdoor 
Model CU-TZ35TKE-1 
POS (EAN) 
5025232874804 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (6-poles) 
Output Power 
700 
Indoor Fan
 
Type  
Cross-flow 
Fan 
Material  
ASG20K1 
Motor Type 
 
DC (8-poles) 
Input Power 
47.3 
Output Power 
30 
Speed 
QLo 
Cool rpm 
650 
Heat rpm 
720 
Lo 
Cool rpm 
900 
Heat rpm 
1030 
Me 
Cool rpm 
1100 
Heat rpm 
1210 
Hi 
Cool rpm 
1300 
Heat rpm 
1390 
SHi 
Cool rpm 
1350 
Heat rpm 
1440 
Outdoo
r Fa
n
 
Type  
Propeller 
Fan 
Material  
PP 
Motor Type 
 
DC (8-poles) 
Input Power 
– 
Output Power 
40 
Speed Hi 
Cool rpm 
830 
Heat rpm 
860 
Moisture Removal 
L/h (Pt/h) 
2.0 (4.2) 
Indoor 
Airflow 
QLo 
Cool m
3
/min (ft
3
/min) (L/s) 
5.12 (181) 
Heat m
3
/min (ft
3
/min) (L/s) 
5.79 (204) 
Lo 
Cool m
3
/min (ft
3
/min) (L/s) 
7.50 (265) 
Heat m
3
/min (ft
3
/min) (L/s) 
8.73 (308) 
Me 
Cool m
3
/min (ft
3
/min) (L/s) 
9.40 (332) 
Heat m
3
/min (ft
3
/min) (L/s) 
10.44 (369) 
Hi 
Cool m
3
/min (ft
3
/min) (L/s) 
11.3 (400) 
Heat m
3
/min (ft
3
/min) (L/s) 
12.1 (425) 
SHi 
Cool m
3
/min (ft
3
/min) (L/s) 
11.77 (416) 
Heat m
3
/min (ft
3
/min) (L/s) 
12.63 (446) 
Outdoor 
Airflow 
Hi 
Cool m
3
/min (ft
3
/min) (L/s) 
29.1 (1025) 
Heat m
3
/min (ft
3
/min) (L/s) 
30.2 (1065) 
Refrigerant 
Cycle 
Control Device 
 
Expansion Valve 
Refrigerant Oil 
cm
3
 FW50S 
(320) 
Refrigerant Type 
g (oz) 
R32, 820 (28.9) 
F-Gas 
GWP 675 
CO2eq (ton) 
(Precharged Amount / Maximum Amount)
0.554 / 0.604 
14 
Indoor 
Model CS-TZ35TKEW-1 
POS (EAN) 
5025232874620 
Outdoor 
Model CU-TZ35TKE-1 
POS (EAN) 
5025232874804 
Dimension Unit 
Height 
(I/D / O/D) 
mm (inch) 
290 (11-7/16) / 542 (21-11/32) 
Width 
(I/D / O/D) 
mm (inch) 
799 (31-15/32) / 780 (30-23/32) 
Depth 
(I/D / O/D) 
mm (inch) 
197 (7-25/32) / 289 (11-13/32) 
Weight 
Net (I/D / O/D) 
kg (lb) 
8 (18) / 33 (73) 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard Length 
m (ft) 
5.0 (16.4) 
Length Range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height Different 
m (ft) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
10 (0.1) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length mm 
650 
Indoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 15 × 21 
Size (W × H × L) 
mm 
610 × 315 × 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 24 × 19 
Size (W × H × L) 
mm 
36.4 × 504 × 824.2:793.7 
Air Filter 
Material  
Polypropelene 
Type  
One-touch 
Power Supply 
 
Outdoor 
Power Supply Cord 
 
Nil 
Thermostat  
Electronic 
Contol 
Protection Device 
 
Electronic Contol 
 
Dry Bulb 
Wet Bulb 
Indoor Operation 
Range 
Cooling 
Maximum °C (°F) 
32 (89.6) 
23 (73.4) 
Minimum °C (°F) 
16 (60.8) 
11 (51.8) 
Heating 
Maximum °C (°F) 
30 (86.0) 
– 
Minimum °C (°F) 
16 (60.8) 
– 
Outdoor Operation 
Range 
Cooling 
Maximum °C (°F) 
43 (109.4) 
26 (78.8) 
Minimum °C (°F) 
-10 (14.0) 
– 
Heating 
Maximum °C (°F) 
24 (75.2) 
18 (64.4) 
Minimum °C (°F) 
-15 (5.0) 
-16 (3.2) 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C 
5. 
Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
15 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2RE15SBE,  
CU-2RE18SBE. 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3RE18SBE. 
 
CONNECTABLE INDOOR UNIT 
OUTDOOR UNIT 
CU-2RE15SBE* CU-2RE18SBE* 
CU-3RE18SBE* 
ROOM 
TYPE 
A B A B A B C 
Wall
 
2.0kW CS-TZ20TKEW-1 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-TZ25TKEW-1 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-TZ35TKEW-1 
● – ● 
● 
● 
● – 
4.2kW CS-TZ42TKEW-1 
– 
– 
● – ● 
● – 
Capacity range of 
connectable indoor units 
From 4.0kW to 5.7kW 
From 4.0kW to 7.5kW 
From 4.5kW to 9.0kW 
Pipe length 
1 room maximum pipe length (m) 
20 
20 
25 
Allowable elevation (m) 
10 
10 
15 
Total allowable pipe length (m) 
30 
30 
50 
Total pipe length for maximum 
chargeless length (m) 
20 20 
30 
Additional gas amount over 
chargeless length (g/m) 
15 15 
20 
Note: “●” : Available 
Remarks for CU-2RE15SBE / CU-2RE18SBE 
1.  The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of  
indoor unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-2RE15SBE. (Total nominal capacity of indoor units is between 
4.0kW to 5.7kW) 
1) Two CS-TZ20TKEW-1 only. (Total nominal cooling capacity is 4.0kW) 
Remarks for CU-3RE18SBE 
1.  The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of  
indoor unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-3RE18SBE. (Total nominal capacity of indoor units is between 
4.5kW to 9.0kW) 
1) Two CS-TZ25TKEW-1 only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
16 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E12SBE, CU-2E15SBE, 
CU-2E18SBE. 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E23SBE. 
 
CONNECTABLE INDOOR UNIT CU-2E12SBE* CU-2E15SBE* CU-2E18SBE* 
CU-3E23SBE* 
ROOM 
A B A B A B A B C 
Wall
 
2.0kW CS-TZ20TKEW-1  ● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-TZ25TKEW-1  ● 
● 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-TZ35TKEW-1  ● – ● – ● 
● 
● 
● 
● 
4.2kW 
CS-TZ42TKEW-1 
– – – – ● – ● 
● – 
Capacity range of connectable units 
From 3.2kW to 5.7kW From 3.2kW to 5.7kW From 3.2kW to 7.5kW
From 4.5kW to 11.0kW 
Pipe length 
1 room maximum pipe length (m) 
20 
20 
20 
25 
Allowable elevation (m) 
10 
10 
10 
15 
Total allowable pipe length (m) 
30 
30 
30 
60 
Total pipe length for maximum 
chargeless length (m) 
20 20 20 
30 
Additional gas amount over 
chargeless length (g/m) 
15 15 15 
20 
Note: “●” : Available 
Remarks for CU-2E12SBE / CU-2E15SBE / CU-2E18SBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-2E15SBE. (Total nominal capacity of indoor units is between 
3.2kW to 5.7kW) 
1) Two CS-TZ20TKEW-1 only. (Total nominal cooling capacity is 4.0kW) 
Remarks for CU-3E23SBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-3E23SBE. (Total nominal capacity of indoor units is between 
4.5kW to 11.0kW) 
1) Two CS-TZ25TKEW-1 only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other CS-TZ20TKEW-1 / CS-TZ25TKEW-1 / CS-TZ35TKEW-1 / CU-TZ20TKE-1 / CU-TZ25TKE-1 / CU-TZ35TKE-1 service manuals if exist.