DOWNLOAD Panasonic CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE Service Manual ↓ Size: 3.01 MB | Pages: 84 in PDF or view online for FREE

Model
CS-PE9CKE CU-PE9CKE CS-PE12CKE CU-PE12CKE
Pages
84
Size
3.01 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-pe9cke-cu-pe9cke-cs-pe12cke-cu-pe12cke.pdf
Date

Panasonic CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE Service Manual ▷ View online

5.Temp Adjusting Button
6.Timer Set Button
 1. Press this button to change the set temperature
 2. If the ON/OFF button is pressed after temperature is set, or change the temperature during operation, or the signal is received
from the remote controller, the indoor indicator will flash or light up to start the operation.
1) The Function of the Timer-Setting Button
 1. SELECT Button
 2. Button A and B
The set time can be changed with manner of 1,2,3,4,5,6,7,8,9,10,11,12,1,2,3,4... by pressing the buttons.Pressing the button
A can change the time for ON Timer and OFF Timer, off time for OFF-ON Timer, on time for ON-OFF Timer; Pressing the button
B can change the time for on time for OFF-ON Timer and off time for ON-OFF Timer setting.
 3. SET/CANCEL Button
Pressing the button to set or cancel the set timer during the timer setting or activate the previous timer setting.After the timer
setting is determined, “ON” or “OFF” will stop flashing. If the timer setting is cancelled, “ON” or“OFF” will disappear on the
remote control display.The time on the remote control will change every hour.
Notes:
 a. During the operation, OFF Timer and OFF- ON Timer can be set.
 b. Duing the operation, if the ON Timer or ON-OFF Timer is set, the operation will be stopped.
 c. 
Timer setting can operate only once.
 d. If the OFF/ON button on the remote control or the AUTO Switch on the indoor unit is pressed, the timer setting will be
cancelled.
 e. If Auto Restart Control occurs , timer setting will be cancelled.
17
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
7.Air Swing Button
8.Display of Diagnosis
9.Change the Code of Remote Controller
2) Timing Chart of Timer-Setting
 1. OFF Timer
 2. ON Timer
 1. The airflow direction will change as follow by pressing the AIR SWING button.
Refer to Diagnosis section.
Keep the "AUTO" switch on the indoor unit depressed for more than 11 seconds until 3 beeps are heard and the other remote
control code will be selected.
18
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
1.AUTO Operation Switch
2.Indoor Unit Indicator
7.2. Operation and Display of Indoor Unit
AUTO Operation
 1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
 2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
 3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
 4. When the switch is pressed between 11 to 16 seconds and together with the signal from the remote controller, the unit can
be changed to different controlling setting (A-B).
 5. When the switch is pressed between 16 to 21 seconds, either H14 error detection selection mode or remote controller’s
signal receiving sound can be cancelled or turned on.
 6. If the intake air temperature is less than 16°C and the Forced Cooling is activated, because the prior operation mode is
heating, the compressor will stop for 3 minutes to start the Forced Cooling operation.
ON
OFF
FLASH
Operation
(Green)
Run
Stop
Hot start, deice control,mode
judging and ON TimerOperation
detecting.
Timer
(Orange)
Timer set
Timer not set
Malfunction happens.
19
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
1.Indoor Fan Motor Control
7.3. Common Features
A. Basic Fan Speed
Fan speed is determined by the setting of the remote control. And W4~W6 can be calculated according the equations
below:
Me- :W4=W3+W10
Me :W5=W4+W10
Me+ :W6=W5+W10
20