PREPARATION BEFORE OPERATION
!
  
Warning
Ensure the power plug is securely inserted.
A loose plug may cause a fire or an electric shock.
5
Insert the air filters
4
Insert the air purifying filters
6
Close the front panel
Notes
Indoor Unit
If the unit is not going to be used for an extended period of time, turn off the main Power supply. If it is left at the ON
position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote
control.
If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
1
Connect the power
supply cord to an
independent power
supply.
3
Remove the air filters
2
Open the front panel
  Use under the following conditions
(Unit in °C)
Outdoor
DBT
32
16
WBT
23
11
Indoor
DBT
43
16
WBT
26
11
Outdoor
DBT
30
16
WBT
_
_
Indoor
DBT
24
-5
WBT
18
-6
Cooling
Heating
  DBT: Dry Bulb Temp
  WBT: Wet Bulb Temp
 Maximum Temperature
 Minimum Temperature
41
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
1
Press the clock button
2
Press to set the current time
Press continuously for fast forwarding.
Press continuously for fast reversing.
3
Press the clock button
Can be used for approximately one year.
Observe the following when replacing the batteries
Replace with new batteries of the same type .
Do not use rechargeable batteries (Ni-Cd).
Remove the batteries if the unit is not going to be used for a long period.
lights up
PM
PM
1
OPEN
Slide the cover to open
2
Be sure the directions are correct
Open the remote control
cover and confirm the
display 12:00 PM
is flashing.
PM
Setting the clock
About the batteries
*
Set the current time (Clock) immediately to prevent battery exhaustion.
flashes
lights up
lights up
Remote Control
Inserting batteries
AIR SWING
TIMER
CLOCK
1
2
3
COOL
PM
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANC
EL
SLEEP
OPEN
42
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
AIR SW
ING
TIMER
CLOCK
1
2
3
COOL
MO
DE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
CANCEL
SLEEP
SET
POWERFUL
OFF/ON
COOL
TEMP
HOW TO OPERATE
Automatic, Heating, Cooling, Soft Dry
Display
Close the Cover
a
HEAT
DRY
COOL
HI
AUTO
AUTO
LO
AUTO
– Automatic Operation
At the start of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected
according to the  indoor temperature.
The operation mode changes every hour, when
necessary.
Temperature is not displayed on remote control during
Auto mode operation
Operation details
           Cooling Operation
To set room temperature to your preference of cooling
comfort.
Setting
temperature
Soft Dry operation with Low
fan speed
Switch to Soft Dry when setting temperature is
reached.
Cooling
Operation
DRY
COOL
COOL
          – Soft Dry Operation
A very gentle Cooling Operation. Consisting primarily of
dehumidifying. It does not lower the room temperature.
During Soft Dry operation, the indoor fan operates at Low fan
speed.
DRY
1
Press to select the desired operation mode
When pressed, the display changes in this order.
2
Press to start the operation
POWER indicator LED (Green) on indoor unit will light up.
Press once more to stop operation.
3
Press to select room temperature
• 
a
 Automatic Operation
Display
- Operation with 2°C higher than standard temperature.
- Operation with standard temperature.
- Operation with 2°C lower than standard temperature.
        Heating,             Cooling,           Soft Dry operation
Press to increase temperature by 1°C.
Press to decrease temperature by 1°C.
The temperature can be set between 16°C and 30°C.
Recommended temperature
For Heating: 20°C - 24°C.
For Cooling: 26°C - 28°C.
For Soft Dry: 1°C - 2°C lower than room temperature.
HEAT
43
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
Adjusting Airflow Direction And Fan Speed
Operation details
*
Five stages of adjustments can be made in
this range.
Louver adjustment range
Press to select Fan speed
The display changes in this order
Automatic
Low
Medium
High
Selecting Vertical Airflow Direction
Press AUTO,
Selecting Vertical Airflow Direction
Press AUTO,
Cooling and Soft Dry – The louver swing up
and down automatically.
Heating – When the discharge air
temperature is low such as at the start of
heating operation, the air blows at
horizontal level. As the temperature rises,
the hot air blows in a downwards direction.
To stop the automatic airflow direction
operation,press  MANUAL  button.
Press MANUAL
Manual selection of Vertical Airflow Direction
Louver.
The display changes in this order.
Horizontal Airflow Direction
Adjust it manually.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
AIR SW
ING
TIMER
CLOCK
1
2
3
COOL
AUTO FAN
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
Heating
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
Cooling
Soft Dry
           – Heating Operation
Defrosing Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor unit.
Heat is obtained from outdoor air to warm up the room.
When the outdoor ambient air temperature falls, the heating
capacity of the unit might be reduced.
We recommend that you use an additional heating device
when the outdoor ambient air temperature is low.
Automatic Airflow Volume
The speed of the Indoor fan is adjusted automatically
according to the operation. The Indoor fan stops occasionally
during cooling operation.
HEAT
44
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
Page of 98
Display

Click on the first or last page to see other CS-MA75KE / CS-MA95KE / CS-MA125KE / CU-MA185KE / CU-MA195KE / CU-MA245KE service manuals if exist.