Panasonic CS-G95KE / CS-G125KE / CU-G95KE / CU-G125KE Service Manual ▷ View online
Fig. 5
Fig. 7
Fig. 9
Fig. 6
Fig. 8
Fig. 10
a. Removal of Electronic Controller Procedure
89
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Fig. 11
Fig. 13
Fig. 15
Fig. 12
Fig. 14
c. Indoor Fan Motor Removal Procedure
90
S-G95KE CU-G95KE / CS-G125KE CU-G125KE
Fig. 16
Fig. 17
Fig. 19
Fig. 18
d. Cross Flow Fan Removal Procedure
1. Remove Discharge Grille
1. Remove Cross Flow Fan
91
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
d. Outdoor Electronic Controller Removal Procedure
1. Remove the top pane and front panel
Fig. 20
2. Remove the Outdoor Electronic Controller
Fig. 22
Caution! When handling electronic
controller, be careful of electrostatic
discharge.
controller, be careful of electrostatic
discharge.
•
Be save to return the wiring to its original position
•
There are many high voltage components within the heat
sink cover so never touch the interior during operation.
Wait at least two minutes after power has been turned off.
sink cover so never touch the interior during operation.
Wait at least two minutes after power has been turned off.
Fig. 21
Fig. 23
Note: Use magnetic type of screw driver to avoid dropping of the
screws.
92
S-G95KE CU-G95KE / CS-G125KE CU-G125KE
Click on the first or last page to see other CS-G95KE / CS-G125KE / CU-G95KE / CU-G125KE service manuals if exist.