Panasonic CS-F24DD2E5 / CS-F28DD2E5 / CS-F34DD2E5 / CS-F43DD2E5 / CS-F50DD2E5 / CU-L24DBE5 / CU-L28DBE5 / CU-L34DBE5 / CU-L43DBE5 / CU-L50DBE8 Service Manual ▷ View online
13.4.2. Heating performance
Model name
Max heating capacity
Max capacity (kw)
Max power consumption (kw)
CS-F24DD2E5 / CU-L24DBE5
7.5
3.15
CS-F28DD2E5 / CU-L28DBE5
8.5
3.25
CS-F34DD2E5 / CU-L34DBE5
13.5
4.3
CS-F43DD2E5 / CU-L43DBE5
15.5
5.1
CS-F50DD2E5 / CU-L50DBE8
18
6.1
1. Heating capacity when the unit is frosted over or while being defrosted will vary depending on outdoor temperature and the
frosting.
2. Heating capacity must be compensated because it does not take into account the capacity drop incurred when the unit is
frosted over and while it is being defrosted.
3. Therefore, to obtain the integral heating capacity in consideration overfrosting and defrost operations.
4. Heating capacity must be multiplied by the compensation coefficient below.
125
13.4.2.1. CS-F24DD2E5 CU-L24DBE5
Heating capacity curve
Outdoor intake air ambient temperature (D.B./ °C)
-20°C -15°C -10°C
-5°C
0°C
2°C
5°C
7°C
10°C
15°C
>15°C
Heating
capacity
0.93
0.93
0.93
0.92
0.84
0.88
0.96
1
1
1
1
compensation
coefficient
126
Heating power consumption curve
Outdoor intake air ambient temperature (D.B./ °C)
-20°C -15°C -10°C
-5°C
0°C
5°C
7°C
10°C
15°C
>15°C
Heating
capacity
0.93
0.93
0.93
0.92
0.86
0.97
1
1
1
1
compensation
coefficient
127
13.4.2.2. CS-F28DD2E5 CU-L28DBE5
Heating capacity curve
Outdoor intake air ambient temperature (D.B./ °C)
-20°C -15°C -10°C
-5°C
0°C
2°C
5°C
7°C
10°C
15°C
>15°C
Heating
capacity
0.93
0.93
0.93
0.92
0.84
0.88
0.96
1
1
1
1
compensation
coefficient
128