Panasonic CS-F24DTE5 / CU-L24DBE5 / CS-F28DTE5 / CU-L28DBE5 / CS-F34DTE5 / CU-L34DBE5 / CS-F43DTE5 / CU-L43DBE5 / CS-F50DTE5 / CU-L50DBE8 Service Manual ▷ View online
1
Service Information
3
1.1.
Example of trouble at test operation
3
1.2.
Caution of test operation
3
1.3.
Caution during automatic address setting
3
1.4.
Operation range
4
2
Features
5
CS-F24DTE5 CU-L24DBE5
CS-F28DTE5 CU-L28DBE5
CS-F34DTE5 CU-L34DBE5
CS-F43DTE5 CU-L43DBE5
CS-F28DTE5 CU-L28DBE5
CS-F34DTE5 CU-L34DBE5
CS-F43DTE5 CU-L43DBE5
CS-F50DTE5 CU-L50DBE8
2.1.
Ceiling type
5
2.2.
Outdoor unit
5
2.3.
A brand-new control method
6
2.4.
Wired Remote Control
7
2.5.
Wireless Remote Control
7
2.6.
Group Control Equipment
8
Air Conditioner
CONTENTS
Page
Page
Order No. MAC0504060C2
3
Specification
9
3.1.
Product Specification
9
4
Dimensions
14
4.1.
CS-F24DTE5 CS-F28DTE5
14
4.2.
CS-F34DTE5 CS-F43DTE5 CS-F50DTE5
15
4.3.
CU-L24DBE5 CU-L28DBE5
16
4.4.
CU-L34DBE5 CU-L43DBE5 CS-L50DBE8
17
5
Refrigeration Cycle
18
6
Block Diagram
19
6.1.
CS-F24DTE5 CS-F28DTE5 CS-F34DTE5 CS-F43DTE5
CS-F50DTE5
19
6.2.
CU-L24DBE5 CU-L28DBE5
20
6.3.
CU-L34DBE5 CU-L43DBE5
21
6.4.
CU-L50DBE8
22
7
Wiring Diagram
23
7.1.
CS-F24DTE5 CS-F28DTE5 CS-F34DTE5 CS-F43DTE5
CS-F50DTE5
23
7.2.
CU-L24DBE5 CU-L28DBE5
24
7.3.
CU-L34DBE5 CU-L43DBE5
25
7.4.
CU-L50DBE8
26
8
Remote Control Operating Instructions
27
8.1.
Wired remote control
27
8.2.
Wireless remote control
28
9
Operation Control
29
9.1.
Operation mode
29
9.2.
Compressor start control
29
9.3.
Cooling operation
29
9.4.
Heating mode operation
31
9.5.
Louver control
34
9.6.
Odour removing operation
35
9.7.
Energy save operation
36
9.8.
Outdoor fan remaining heat removal control
36
9.9.
Crank case heater control
36
9.10. Valve error
36
9.11. Pump down operation
37
10 Installation Instruction
38
10.1. Pipe length
38
10.2. Refrigerant additional charge
40
10.3. Position of the centre gravity
40
10.4. Indoor unit installation
41
10.5. Outdoor unit installation
50
10.6. Wired remote control installation
61
10.7. Wireless remote control installation manual
68
10.8. Twin systems installation
75
10.9. Twin
76
11 Installation and Servicing Air Conditioner Using R410A
77
11.1. Outline
77
11.2. Tools for installing/servicing refrigerant piping
78
11.3. Refrigerant piping work
82
11.4. Installation, transferring, servicing
84
12 Trouble Shooting Guide
88
12.1. For standard installation
88
12.2. During twin operation
90
12.3. During group control operation
92
12.4. Address setting for twin system
93
12.5. Address setting for group control system
94
12.6. Wiring mistake prevention
96
12.7. Test operation and self diagnosis
97
12.8. Emergency operation
101
12.9. Self-diagnosis
102
13 Technical Data
104
13.1. Sound data
104
13.2. Sound measurement point
109
13.3. Reaching distance
110
13.4. Discharge and suction pressure
112
13.5. Capacity and power consumption
117
13.6. Fan performance
144
13.7. Safety device
147
13.8. Operating characteristics
148
14 Replacement Parts
149
14.1. Indoor unit
149
14.2. Outdoor unit
158
15 Electronic Circuit Diagram
170
15.1. Indoor unit
170
15.2. Outdoor unit
174
15.3. Wired remote control
186
15.4. Wireless remote control
187
15.5. Print pattern
188
2
1 Service Information
Notice of Address setting for NEW Ceiling / NEW Outdoor Unit.
The new Ceiling / New Outdoor models are possible to have address setting for twin control by automatic when main
power supply is switched on.
power supply is switched on.
(Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However, this address setting is only
possible when made proper wiring connection and also Indoor unit should be original virgin unit.
possible when made proper wiring connection and also Indoor unit should be original virgin unit.
1.1. Example of trouble at test operation
If found out as following phenomenon at test operation on site, it may have possibility of wrong address setting.
Therefore, please ensure of the address setting.
Therefore, please ensure of the address setting.
1. LCD display of wired remote control had not illuminate although the main power supply switch is ‘on’.
2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoor unit cannot be operated.
(But, it is necessary to take 3 to 5 minutes for outdoor unit to start from the timing of remote control ON/OFF switch is ‘on’.)
3. P.C. board had memorized wrong setting information.
a. If main power supply is switched ‘on’ with the wrong connection.
b. When changing the connection or combination of units due to re-installation etc.
• When changing the system from twin control to normal one to one system.
• When making the replacement of units as master and slave etc.
• When making the replacement of units as master and slave etc.
1.2. Caution of test operation
Do not touch the remote control switch and do not change any wirings for one minute when the main power supply switch is ‘on’.
(Because the unit is having automatic address setting during the first one minute.)
(Because the unit is having automatic address setting during the first one minute.)
1.3. Caution during automatic address setting
When main power supply switch is ‘on’, the P.C. board will automatically memorized the connecting system.
Consequently, when initial power supply is ‘on’, there will not be interchangeability of units even of the same type and same
capacity unit. Therefore unable to connect the unit to another system.
Consequently, when initial power supply is ‘on’, there will not be interchangeability of units even of the same type and same
capacity unit. Therefore unable to connect the unit to another system.
3
1.4. Operation range
1.4.1. Power Supply
The applicable voltage range for each unit is given in the following table. The working voltage among the three phases must be
balanced within a 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher than 85% of
the rated voltage.
balanced within a 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher than 85% of
the rated voltage.
MODEL
Unit Main Power
Applicable Voltage
CU-
Phase, Volts
Hz
Max
Min
L24DBE5
L28DBE5
L34DBE5
L43DBE5
L28DBE5
L34DBE5
L43DBE5
1~240
50
264
216
1~220
50
242
198
1~230
50
253
207
L50DBE8
3N~380
50
418
342
3N~400
50
440
360
3N~415
50
457
374
1.4.2. Indoor and Outdoor Temperature
• Model 50Hz CU-L24DBE5, CU-L28DBE5, CU-L34DBE5, CU-L43DBE5, CU-L50DBE8
Operating
Hz
Indoor Temp. (D.B./W.B.) (°C)
Outdoor Temp. (D.B./W.B.) (°C)
Max
Min
Max
Min
Cooling
50
32/23
21/15
43/-
-15/-
Heating
50
27/-
16/-
24/18
-20/-
4