Panasonic CS-F24DB4E5 / CU-B24DBE5 / CS-F28DB4E5 / CU-B28DBE5 / CS-F28DB4E5 / CU-B28DBE8 / CS-F34DB4E5 / CU-B34DBE5 / CS-F34DB4E5 / CU-B34DBE8 / CS-F43DB4E5 / CU-B43DBE8 / CS-F50DB4E5 / CU-B50DBE8 Service Manual ▷ View online
125
HC: Heating Capacity
IPT: Heating Power Consumption
Model
Heating capacities are based on conditions
CS-F34DB4E5
3 phase, 50Hz 400V
Heating capacity
Indoor temp. 20
°C D.B.
11.2kW
Outdoor temp. 7
°C D.B. 6°C W.B.
Standard air volume 27 m
3
/min
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
HC
HC
HC
HC
D.B.
kW
kW
kW
kW
15
8.18
9.80
11.76
13.66
20
7.73
9.24
11.20
13.44
25
7.28
8.74
10.64
12.88
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
IPT
IPT
IPT
IPT
D.B.
kW
kW
kW
kW
15
2.65
3.02
3.59
4.23
20
2.80
3.21
3.78
4.38
25
2.95
3.40
3.97
4.48
126
HC: Heating Capacity
IPT: Heating Power Consumption
Model
Heating capacities are based on conditions
CS-F43DB4E5
3 phase, 50Hz 400V
Heating capacity
Indoor temp. 20
°C D.B.
14.0kW
Outdoor temp. 7
°C D.B. 6°C W.B.
Standard air volume 31 m
3
/min
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
HC
HC
HC
HC
D.B.
kW
kW
kW
kW
15
10.22
12.25
14.70
17.08
20
9.66
11.55
14.00
16.80
25
9.10
10.92
13.30
16.10
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
IPT
IPT
IPT
IPT
D.B.
kW
kW
kW
kW
15
3.28
3.75
4.46
5.25
20
3.47
3.99
4.69
5.44
25
3.66
4.22
4.92
5.56
127
HC: Heating Capacity
IPT: Heating Power Consumption
Model
Heating capacities are based on conditions
CS-F50DB4E5
3 phase, 50Hz 400V
Heating capacity
Indoor temp. 20
°C D.B.
15.0kW
Outdoor temp. 7
°C D.B. 6°C W.B.
Standard air volume 32 m
3
/min
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
HC
HC
HC
HC
D.B.
kW
kW
kW
kW
15
10.95
13.13
15.75
18.30
20
10.35
12.38
15.00
18.00
25
9.75
11.70
14.25
17.25
Ambient
Temperature Air Entering Condenser (
°C D.B.)
Return
-6
°C
0
°C
6
°C
12
°C
Air
IPT
IPT
IPT
IPT
D.B.
kW
kW
kW
kW
15
3.52
4.02
4.78
5.63
20
3.72
4.28
5.03
5.83
25
3.92
4.53
5.28
5.96
128
13.4. Reaching distance
Cooling Mode
CS-F24DB4E5
CS-F24DB4E5
CS-F28DB4E5
CS-F34DB4E5
CS-F43DB4E5
CS-F50DB4E5