29
9.6.
Normal Control
9.6.1.
Cooling Indoor Fan Control
• Manual Fan Speed
Operation starts at High, Medium or Low speed set by remote control.
• Auto Fan Speed
When operation start, or shifting to thermostat ON condition from thermostat OFF condition, indoor fan operates as below.
9.6.2.
Heating Indoor Fan Control
• Manual Fan Speed
Operation starts at High, Medium or Low speed set by remote control.
However, when operation start, or during operation, fan speed control is limited due to prevent a cold draft, for example, when
heating operation start.
• Auto Fan Speed
When operation start, or shifting to thermostat ON condition from thermostat OFF condition, indoor fan operates as below.
• If thermostat is off, indoor fan fixed low speed; Louver angle fixed at upper limit, regardless remote control setting.
Thermostat & Compres-
sor ON/OFF
Thermostat &
Compressor ON
Thermostat &
Compressor OFF
Thermostat &
Compressor ON
Time
40 sec.
50 sec.
-
20 sec.
120 sec.
20 sec.
40 sec.
50 sec.
-
Cooling
Auto
Off
Lo
Hi
Lo
Off
Lo
Off
Lo
Me
Soft Dry
Auto
Off
Lo
Lo
Lo
Off
Lo
Off
Lo
Lo
30
9.6.3.
Louver Control
• When power is on, at the same time, louver start initializing toward to close Direction.
• During operation, stopping, thermostat off condition, louver angle set manual or auto depend on remote controller setting.
Manual louver setting
Auto louver setting
• Temperature range for louver control during heating operation is as follows; decide by indoor heat exchanger temperature.
Operation Mode
Display
manual
Set 1
Set 2
Set 3
Set 4
Normal
20
°
35
°
50
°
70
°
Heating
Deice
10
°
Hot start
10
°
Thermostat Off
20
°
Fan
20
°
35
°
50
°
70
°
Cooling
Normal
20
°
35
°
50
°
70
°
(Fan)
Dew Control
50
°
Thermostat Off
20
°
35
°
50
°
70
°
Normal
30
°
Soft Dry
Dew Control
50
°
Thermostat Off
20
°
35
°
50
°
70
°
Operation mode judge
20
°
35
°
50
°
70
°
Stop Mode
0
°
Operation
Display
auto
set
AUTO  1
AUTO  2
AUTO  3
A
70
°
70
°
70
°
Normal
Sensor
B
20
° - 70°
20
° - 50°
40
° - 70°
Heating
C
20
°
20
°
20
°
Deice
10
°
Hot Start
10
°
Thermostat Off
20
°
Fan
20
° - 70°
20
° - 50°
40
° - 70°
Cooling
Normal
20
° - 70°
20
° - 50°
40
° - 70°
(Fan)
Dew Control
50
°
Thermostat Off
20
° - 70°
20
° - 50°
40
° - 70°
Normal
30
°
Soft Dry
Dew Control
50
°
Thermostat Off
20
° - 70°
20
° - 50°
40
° - 70°
Operation mode judge
20
°
20
°
20
°
Stop Mode
0
°
31
9.6.4.
Cooling Outdoor Fan Control
• During cooling operation, outdoor fan speed changes according to outdoor pipe temperature.
• The fan speed is controlled by the timing of turning the outdoor fan ON and OFF within an interval.
• When outdoor pipe temperature increase, interval timing increased.
• Outdoor fan ON time is a variable with the range of 200ms to 2000ms.
• After 2 minutes, the outdoor pipe temperature is detected and the outdoor unit fan speed is changed automatically.
9.6.5.
Heating Outdoor Fan Control
• During heating operation, the fan speed is controlled by indoor heat exchanger temperature.
• In case of twin operation, the higher indoor heat exchanger temperature is used to control the fan speed. During heating opera-
tion, the fan speed is controlled by indoor heat exchanger temperature.
9.7.
Operation Control
9.7.1.
Odour Cut Control
• Odour cut operation removes the odour generated at indoor heat exchanger by using drain water come out from indoor heat
exchanger.
• Press “Odour” button at remote control to enable odour cut operation.
• Odour cut operation starts when compressor or thermostat is on.
9.7.2.
Drain pump Control
• During Cooling, Soft Dry or Deice operation, drain pump operates by following the table below.
• When compressor start, drain pump operating starts after 10 seconds of indoor fan starts.
Thermostat & Compres-
sor ON/OFF
Thermostat &
Compressor ON
Thermostat &
Compressor OFF
Thermostat &
Compressor ON
Time
40 sec.
50 sec.
-
20 sec.
120 sec.
20 sec.
40 sec.
50 sec.
-
Cooling
Off
Lo
Normal
Operation
Lo
Off
Lo
Off
Lo
Normal
Operation
Soft Dry
Off
Lo
Lo
Lo
Off
Lo
Off
Lo
Lo
32
• When operation stop or thermostat is off, drain pump continue operates for 6 minutes to prevent the drain water from coming
back.
9.7.3.
Powerful Control
• To achieve setting temperature quickly.
• Cooling powerful operation:
• Setting temperature and thermostat shifting temperature are decrease by 2°C (lower limit 16°C).
- Airflow direction is optimized regardless the air flow setting at remote control.
- Fan speed is optimized at Hi regardless the fan speed setting at remote control.
• Soft Dry powerful operation:
- Setting temperature and thermostat shifting temperature are decrease by 2°C (lower limit 16°C).
- Airflow direction follows remote control setting.
• Heating powerful operation:
- Setting temperature and thermostat shifting temperature are increase by 2°C (upper limit 31°C).
- Airflow direction is optimized regardless the air flow setting at remote control.
- Fan speed is optimized at Hi regardless the fan speed setting at remote control.
• During powerful operation, the powerful indicator lights on.
• Powerful operation cancel when:
- Powerful operates for more than 15 minutes.
- Powerful button is pressed again.
- Operation mode changed.
- Operation stopped by remote control or emergency button.
- OFF timer is activated.
9.7.4.
Hot Start Operation Control
• Hot start control operates at the starting of heating operation, where [PREHEAT] displayed at wired remote control / [POWER
LED] blinking at control panel of indoor unit.
• Indoor fan stops and louver angle fixed at upper limit in spite of any setting of remote control until hot start control ends (indoor
heat exchanger temperature increases or 4 minutes past heating operation starts), fan and louver control resume.
Page of 127