 1 
SERVICE INFORMATION 
3
 1.1. 
Example of trouble at test operation 
3
 1.2. 
Caution of test operation 
3
 1.3. 
Caution during automatic address setting 
3
 1.4. 
Caution during installation 
3
 1.5. 
Operation range 
3
 2 
FEATURES 
4
 2.1. 
Hide-away type 
4
 2.2. 
Outdoor unit 
4
 2.3. 
A brand-new control method using the latest in technology
 
5
 3 
SPECIFICATION 
6
 3.1. 
CS-F14DD3E5 CU-B14DBE5 
6
 3.2. 
CS-F18DD3E5 CU-B18DBE5 
7
 4 
DIMENSIONS 
8
CS-F14DD3E5 CU-B14DBE5
CS-F18DD3E5 CU-B18DBE5
 4.1. 
CS-F14DD3E5 CS-F18DD3E5 
8
 4.2. 
CU-B14DBE5 CU-B18DBE5 
9
 5 
REFRIGERATION CYCLE 
10
 5.1. 
CS-F14DD3E5 CU-B14DBE5 CS-F18DD3E5 CU-
B18DBE5 
10
 6 
BLOCK DIAGRAM 
11
 6.1. 
CS-F14DD3E5 CS-F18DD3E5  
11
 6.2. 
CU-B14DBE5 
11
 6.3. 
CU-B18DBE5 
12
 7 
WIRING DIAGRAM 
13
 7.1. 
CS-F14DD3E5 CS-F18DD3E5 
13
 7.2. 
CU-B14DBE5 
14
 7.3. 
CU-B18DBE5 
15
 8 
WIRED REMOTE CONTROL OPERATING INSTRUCTIONS  16
 8.1. 
Name and function of each part 
16
Air Conditioner
CONTENTS
 Page 
Page
ORDER NO. MAC0602013C2
 8.2. 
Remote control - display 
17
 8.3. 
Remote control - panel 
18
 8.4. 
How to set remote control day and time 
19
 8.5. 
How to select the timer 
19
 8.6. 
Daily timer setting 
20
 8.7. 
Weekly timer setting 
21
 9 
OPERATION DETAIL 
23
 9.1. 
Cooling operation 
23
 9.2. 
Heating operation 
24
 9.3. 
Soft dry operation 
24
 9.4. 
Auto operation 
24
 9.5. 
Fan operation 
24
 9.6. 
Normal control 
25
 9.7. 
Operation control 
26
 9.8. 
Protection control 
29
 9.9. 
Test run 
31
 10 INSTALLATION INSTRUCTION 
32
 10.1. Pipe length 
32
 10.2. Position of the centre gravity 
33
 10.3. Indoor unit installation 
34
 10.4. Outdoor unit installation 
45
 10.5. Wired remote controller installation 
56
 11 INSTALLATION & SERVICING AIR CONDITIONER 
63
 11.1. Outline 
63
 11.2. Tools for installing/servicing refrigerant piping 
64
 11.3. Refrigerant piping work 
68
 11.4. Installation, transferring, servicing 
70
 12 TROUBLE SHOOTING GUIDE 
74
 12.1. For standard installation 
74
 12.2. During twin operation 
76
 12.3. During group control operation 
78
 12.4. Test operation and self diagnosis 
79
 12.5. Emergency operation 
82
 12.6. Self-diagnosis error code table 
83
 13 TECHNICAL DATA 
85
 13.1. Sound data 
85
 13.2. Sound measurement point 
87
 13.3. Discharge and suction pressure 
88
 13.4. Capacity and power consumption 
90
 13.5. Fan performance 
95
 13.6. Safety device 
97
 13.7. Operating characteristics 
98
 14 REPLACEMENT PARTS 
99
 14.1. Indoor unit 
99
 14.2. Outdoor unit 
101
 15 PRINT PATTERN 
104
 15.1. Indoor unit 
104
 15.2. Outdoor unit 
105
2
1 SERVICE INFORMATION
Notice of Address setting for NEW Duct / NEW Outdoor Unit.
The new Duct Type / New Outdoor models are possible to have address setting for twin control by automatic when main
power supply is switched on.
(Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However, this address setting is only
possible when made proper wiring connection and also Indoor unit should be original virgin unit
.
1.1. Example of trouble at test operation
If found out as following phenomenon at test operation on site, it may have possibility of wrong address setting.
Therefore, please ensure of the address setting.
 1. LCD display of wired remote control had not illuminate although the main power supply switch is ‘on’.
 2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoor unit cannot be operated.
(But, it is necessary to take 3 to 5 minutes for outdoor unit to start from the timing of remote control ON/OFF switch is ‘on’.)
 3. P.C. board had memorized wrong setting information.
 a. If main power supply is switched ‘on’ with the wrong connection.
 b. When changing the connection or combination of units due to re-installation etc.
 • When changing the system from twin control to normal one to one system.
 • When making the replacement of units as master and slave etc.
1.2. Caution of test operation
Do not touch the remote control switch and do not change any wirings for one minute when the main power supply switch is ‘on’.
(Because the unit is having automatic address setting during the first one minute.)
1.3. Caution during automatic address setting
When main power supply switch is ‘on’, the P.C. board will automatically memorized the connecting system.
Consequently, when initial power supply is ‘on’, there will not be interchangeability of units even of the same type and same
capacity unit. Therefore unable to connect the unit to another system.
1.4. Caution during installation
To protect the compressor, after installation of new unit/pump down, be sure to select cooling mode first, and run the unit in this
mode for 5 minutes or more.
If the cooling operation is not executed first for five minutes or more, the heating operation cannot be executed.
1.5. Operation range
The applicable voltage range for each unit is given in “the following table”. The working voltage among the three phases must be
balanced within 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher than 85% of the
rated voltage.
1.5.1. Power Supply
Model
CU-
Unit Main Power
Applicable Voltage
Phase, Volts
Hz
Maximum
Minimum
B14DBE5
B18DBE5
1~220
50
242
198
1~230
50
253
207
1~240
50
264
216
1.5.2. Indoor and Outdoor Temperature
Model 50Hz ... B14DBE5, B18DBE5
Operating
Hz
Indoor Temp. (D.B./W.B.) (°C)
Outdoor Temp. (D.B./W.B.) (°C)
Maximum
Minimum
Maximum
Minimum
Cooling
50
32/23
21/15
43/-
5/-
Heating
50
27/-
16/-
24/18
-10/-
3
2.1. Hide-away type
2.1.1. Compact design
 • The height has been reduced to 25 cm, the equipment can
be installed in limited spaces.
2.1.2. Versatile installation
 • The indoor unit is designed in order that air will also enter
from below, for easier installation under different conditions.
 • The equipment has two drain outlets on the right and left
side for adoption to the installation conditions in the
building.
2.1.3. Easy maintenance
 • Equipped with a filter as standard. The filter can be
removed in three directions for easier maintenance.
2.2. Outdoor unit
 • Long pipe design with a maximum piping length of 30m.
 • Additional charging of refrigerant are not required for 20m
of pipe length.
 • Flexible 4-way piping.
 • Centralized drain method gather multiple outdoor units’
drain pipes into a single drain pipe to make installation
easier and also improve appearance.
 • Side-by-side continuous installation is possible even for
outdoor units with different capacities.
2 FEATURES
4
Page of 105
Display

Panasonic CS-F14DD3E5 / CU-B14DBE5 / CS-F18DD3E5 / CU-B18DBE5 Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-F14DD3E5 / CU-B14DBE5 / CS-F18DD3E5 / CU-B18DBE5 Service Manual ↓ Size: 11.56 MB | Pages: 105 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-F14DD3E5 / CU-B14DBE5 / CS-F18DD3E5 / CU-B18DBE5 in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-F14DD3E5 / CU-B14DBE5 / CS-F18DD3E5 / CU-B18DBE5 Air Conditioner. Information contained in Panasonic CS-F14DD3E5 / CU-B14DBE5 / CS-F18DD3E5 / CU-B18DBE5 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.