DOWNLOAD Panasonic CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD Service Manual ↓ Size: 27.85 MB | Pages: 127 in PDF or view online for FREE

Model
CS-E7PKDW CS-E9PKDW CS-E12PKDW CS-E15PKDW CS-E18PKDW CS-E24PKDW CU-E7PKD CU-E9PKD CU-E12PKD CU-E15PKD CU-E18PKD CU-E24PKD
Pages
127
Size
27.85 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e7pkdw-cs-e9pkdw-cs-e12pkdw-cs-e15pkdw-cs-e18pk.pdf
Date

Panasonic CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD Service Manual ▷ View online

117 
17.4.24  F95 (Outdoor High Pressure Protection: Cooling or Soft Dry) 
Malfunction Decision Conditions 
š  During operation of cooling or soft dry, when outdoor unit heat exchanger high temperature data is detected by 
the outdoor unit heat exchanger thermistor. 
 
Malfunction Caused 
š  Outdoor heat exchanger temperature rise due to short-circuit of hot discharge air flow. 
š  Outdoor heat exchanger temperature rise due to defective of outdoor fan motor. 
š  Outdoor heat exchanger temperature rise due to defective outdoor heat exchanger thermistor. 
š  Outdoor heat exchanger temperature rise due to defective of outdoor unit PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
118 
17.4.25 F96 (IPM Overheating) 
Malfunction Decision Conditions 
š  During operating of cooling and heating, when IPM temperature data (100°C) is detected by the IPM temperature 
sensor. 
Multi Models only 
o
  Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated. 
o
  Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is 
detected by the heat sink temperature sensor. 
 
Malfunction Caused 
š  IPM overheats due to short circuit of hot discharge air flow. 
š  IPM overheats due to defective of outdoor fan motor. 
š  IPM overheats due to defective of internal circuitry of IPM. 
š  IPM overheats due to defective IPM temperature sensor. 
Multi Models Only 
o
  Compressor OL connector poor contact. 
o
 Compressor 
OL 
faulty. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
119 
17.4.26  F97 (Compressor Overheating) 
Malfunction Decision Conditions 
š  During operation of cooling and heating, when compressor tank temperature data (112°C) is detected by the 
compressor tank temperature sensor. 
 
Malfunction Caused 
š  Faulty compressor tank temperature sensor 
š  2/3 way valve closed 
š Refrigerant 
shortage 
(refrigerant leakage) 
š  Faulty outdoor unit PCB 
š Faulty 
compressor 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
120 
17.4.27 F98 (Input Over Current Detection) 
Malfunction Decision Conditions 
š  During operation of cooling and heating, when an input over-current (X value in Total Running Current Control) is 
detected by checking the input current value being detected by current transformer (CT) with the compressor 
running. 
 
Malfunction Caused 
š Excessive 
refrigerant. 
š  Faulty outdoor unit PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display