29
11.4.5.
CONNECT THE CABLE TO THE OUTDOOR UNIT
(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)
1. Remove the control board cover from the unit by loosening the screw.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm
2
 flexible
cord, type designation 245 IEC 57 or heavier cord.
3. Secure the cable onto the control board with the holder
(clamper).
4. Cable connection to the power supply through knife
switch (Disconnecting means).
• Connect the approved polychloroprene sheathed power
supply cable (3 x 1.5 mm
2
), type designation 245 IEC 57
or heavier cord to the terminal board, and connect the
other end of the cable to knife switch (Disconnecting
means).
5. For wire stripping and connection requirement, refer to
instruction 6 of indoor unit.
Note: Knife switch (Disconnecting means) should have
minimum 3.5 mm contact gap.
• Secure the cable onto the control board with the holder
(clamper).
• Power supply earth cable must connect to the left earth
terminal.
11.4.6.
PIPE INSULATION
1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap
the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E
FOAM with thickness 6 mm or above.
• If a drain elbow is used, the unit should be placed on a stand
which is taller than 3 cm.
• If the unit is used in an area where temperature falls below
0
°C for 2 or 3 days in succession, it is recommended not to
use a drain elbow, for the drain water freezes and the fan will
not rotate.
The following operations can be performed by pressing the
“AUTO” switch.
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the
Auto Switch is pressed.
2. TEST RUN OPERATION (FOR PUMP DOWN/
SERVICING PURPOSE)
The Test Run operation will be activated if the Auto
Switch is pressed continuously for more than 5 sec. to
below 8 sec. A “pep” sound will occur at the fifth sec., in
order to identify the starting of Test Run operation.
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
AUTO SWITCH OPERATION
30
1. Press AUTO SW continuously for 11 seconds (buzzer
sound = pep pep pep)
2. After 11 seconds, release AUTO SW, then press Remo-
Con TIMER “
” SW continuously for 5 seconds. Reset
code will be transmitted. After the reset code is
transmitted, release TIMER “
” SW.
3. Press Remo-Con “OFF/ON” button. The new Remo-Con
No. will be accepted and memorized, after which the new
Remo-Con No. can be used.
1. Remove the batteries from the battery compartment of
the Remote Control.
2. On the left side of the battery compartment, there is a
small opening in the centre in which Jumper (J_A) can be
seen. In the accepted Remo-Con PCB shown beside,
Jumper (J_B) can be seen.
• Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature
control, etc.)
• With regards to installation of the parts sold separately, follow the installation manual which is provided with the parts sold
separately.
CHANGING THE REMOTE CONTROL TRANSMISSION
CODE
REMO-CON NO. CHANGE IN REMOTE CONTROL
J_A
J_B
Remo-Con No.
Short
Open
A (Default)
Open
Open
B
Short
Short
C
Open
Short
D
CHECK ITEMS
Is there any gas leakage at flare nut connections?
Is the cooling/heating operation normal?
Has the heat insulation been carried out at flare nut connections?
Is the indoor unit properly secured to the installation plate?
Is the connecting cable being fixed to the terminal board firmly?
Is the power supply voltage complied with rated value?
Is the connecting cable being clamped firmly?
Is there any abnormal sound?
Is the drainage OK?
Is the thermostat operation normal?
Is the Earth wire connection properly done?
Is the remote control’s LCD operation normal?
HAND OVER
As to parts to be sold separately
31
12 Operation and Control
12.1. Basic Function
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes,
automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the
microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature
shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that
judging the condition according to internal setting temperature and intake air temperature.
12.1.1.
Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes.
These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value
will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.
12.1.2.
Cooling Operation
12.1.2.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5
°C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
12.1.3.
Soft Dry Operation
12.1.3.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperate < -2.0
°C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
12.1.4.
Heating Operation
12.1.4.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperate > +2.0
°C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF
point.
32
12.1.5.
Automatic Operation
• This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control
operation mode, indoor intake air temperature and outdoor air temperature.
• During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to
detect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.
Every 30 minutes, the indoor and outdoor temperature is judged. Based on remote control setting temperature, the value of T1 will
increase up to 10
°C, T2 will decreased by 3°C and T3 will decreased up to 8°C.
The Auto Operation Mode shifting will take place whenever operation mode changed from Cooling/Soft Dry to Heating or vice
versa.
12.1.6.
Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry]
• Fan motor’s number of rotation is determined according to remote control setting.
[Heating]
• Fan motor’s number of rotation is determined according to remote control setting.
ii. Auto Fan Speed
[Cooling, Dry]
• According to room temperature and setting temperature, indoor fan speed is determined automatically.
• The indoor fan will operate according to pattern below.
Remote Control
O
O
O
O
O
Tab (rpm)
Hi
Me+
Me
Me-
Lo
Remote Control
O
O
O
O
O
Tab (rpm)
Shi
Me+
Me
Me-
Lo
Page of 87
Display