DOWNLOAD Panasonic CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD Service Manual ↓ Size: 8.02 MB | Pages: 117 in PDF or view online for FREE

Model
CS-E18JKDW CU-E18JKD CS-E21JKDW CU-E21JKD CS-XE18JKDW CU-XE18JKD
Pages
117
Size
8.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e18jkdw-cu-e18jkd-cs-e21jkdw-cu-e21jkd-cs-xe18j.pdf
Date

Panasonic CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD Service Manual ▷ View online

109
Cooling Characteristic at Different Piping Length
Condition
Indoor room temperature: 27/19
qC, 35/-qC
Remote control setting: HI FAN, COOL 16
qC
Compressor frequency: F
c
Voltage: 220/230 V
110
Heating Characteristic at Different Outdoor Air Temperature
Condition
Indoor room temperature: 20/-
qC
Remote control setting: HI FAN, HEAT 30
qC
Compressor frequency: F
h
Voltage: 220/230 V
111
Heating Characteristic at Different Piping Length
Condition
Indoor room temperature: 20/-
qC, 7/6qC
Remote control setting: HI FAN, HEAT 30
qC
Compressor frequency: F
h
Voltage: 220/230 V
112
18.2. Sensible Capacity Chart
CS-E18JKDW  CS-XE18JKDW  CU-E18JKD
CS-E21JKDW  CU-E21JKD
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
4.96
3.76
1.35
4.64
3.61
1.45
4.31
3.47
1.55
3.92
3.29
1.67
19.0
qC
5.00
1.47
19.5
qC
5.45
3.94
1.37
5.09
3.78
1.48
4.74
3.64
1.58
4.31
3.47
1.70
22.0
qC
5.94
4.08
1.40
5.55
3.93
1.50
5.16
3.79
1.61
4.69
3.61
1.73
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.25
4.74
2.02
5.84
4.54
2.18
5.43
4.37
2.33
4.94
4.15
2.51
19.0
qC
6.30
2.21
19.5
qC
6.86
4.96
2.06
6.41
4.77
2.22
5.97
4.59
2.37
5.42
4.37
2.56
22.0
qC
7.48
5.14
2.10
6.99
4.95
2.26
6.50
4.77
2.42
5.91
4.55
2.61
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Page of 117
Display