Panasonic CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD Service Manual ▷ View online
101
17.1.6.
To remove cross flow fan and indoor fan motor
102
103
17.2. Outdoor Electronic Controller Removal Procedure
1. Remove the 4 screws of the Top Panel.
Fig. 1
2. Remove the 10 screws of the Front Panel.
Fig. 2
3. Remove the Top Cover of the Electronic Controller.
Fig. 3
4. Remove the Control Board.
Fig. 4
5. Remove the 8 screws of the Electronic Controller.
Fig. 5
Caution! When handling electronic controller, be careful of
electrostatic discharge.
electrostatic discharge.
104
18 Technical Data
18.1. Operation Characteristics
18.1.1.
CS-E18JKDW CS-XE18JKDW CU-E18JKD
Cooling Characteristic at Different Outdoor Air Temperature
Condition
Indoor room temperature: 27/19
Indoor room temperature: 27/19
qC
Remote control setting: HI FAN, COOL 16
qC
Compressor frequency: F
c
Voltage: 220/230 V
Click on the first or last page to see other CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD service manuals if exist.