29 
12.2  Soft Dry Operation 
x  Soft Dry operation can be set using remote control. 
x  Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room. 
x  This operation starts when the intake air temperature sensor reaches -1.5°C from the setting temperature on the 
remote control. 
x  When operation begins, Soft Dry will be switched ON for a maximum 10 minutes, then Soft Dry operation will be 
turned OFF for a minimum 6 minutes. After that, the Soft Dry operation will be ON and OFF based on the setting 
temperature as shown in figure below. 
x  However after 3 minutes of compressor off, during Soft Dry OFF (within 6 minutes Soft Dry restart control), the 
indoor unit will start to operate at normal Cooling mode if the intake temperature is higher than Cooling ON point. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12.2.1 
Soft Dry Operation Time Diagram 
a b c d e f  g h i  j  k  l  m n o p q r  s  t  u v w x y  z 
Intake 
Air 
Temperature 
 
                             
1.5°C  
 
 Cooling 
ON 
 
Set Temp. 
 
Cooling OFF 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.0°C 
 
 
 
Dry OFF, ON 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10°C 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Indoor Heat 
Exchanger 
Temperature 
2°C 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Time Frame 
   10’  6’ 1’
  6’   1’
6’  1’
      4’ 
6’    
Compressor 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Indoor Fan 
 
  Lo- Lo-
  * 
*    Lo-
*   *  Lo- Lo-   
  Lo- Lo-
  * Lo-
Outdoor Fan 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Operation LED 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
<Description of operation> 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Operation 
g – h, l – m, o – p 
: Minimum 60 seconds forced operation 
 
 
 
a – c 
: Minimum 3 minutes restart control (Time Delay Safety Control) –  
  Cooling operation 
   
 
 
 
 
 Stop 
c – e 
: 10 minutes dry operation 
 
 
 
e – g, i – k, m – o, v – x 
: Minimum 6 minutes restart control (Time Delay Safety Control) –  
  Soft dry operation 
 
 
 
 
 
 
t – x 
: Freeze Prevention Control 
 
 
 
 
 
 
: Indoor fan OFF for 40” and then rotates at Lo- 
 
 
 
 
 
 
 
Intake air 
temperature 
Cooling 
Dry 
Cooling OFF,  
Soft Dry ON point 
Soft Dry OFF point 
Soft Dry OFF 
1.5
ƱC
1.0
ƱC
Cooling ON point
Soft Dry ON point 
Compressor 
ON 
Compressor 
OFF 
30 
12.3 Automatic Operation  
x  Automatic operation can be set using remote control. 
x  This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature. 
x  After judged the temperature, the operation mode is determined by referring to the below standard. 
 
 
 
x  Then, the unit starts to operate at determined operation mode, until it is switched off using remote control, with 
the setting temperature as shown in table below. 
 
 
Setting Temperature (Standard) 
Cooling Operation 
25°C 
Soft Dry Operation 
22°C 
 
x  The setting temperature for all the operations can be changed one level up or one level down from the standard 
temperature as shown in table below by pressing the temperature up or temperature down button at remote 
control. 
 
 Cooling 
Soft 
Dry 
Higher 
Æ +2°C  27°C 
24°C 
Standard 
Æ ±0°C
25°C 
22°C 
Lower 
Æ -2°C
23°C 
20°C 
 
x  The operation mode judging temperature and standard setting temperature can be increased by 2°C 
permanently, by open the circuit of JX03 at indoor unit’s printed circuit board. 
 
 
 
 
 
 
Setting Temperature (Standard) 
Cooling Operation 
 
Cooling Operation 
27°C 
Intake Air 
Temperature 
 
25°C 
 
Soft Dry Operation 
 
Soft Dry Operation 
24°C 
 
Cooling Operation 
Intake Air 
Temperature 
 
23°C 
 
Soft Dry Operation 
31 
12.4  Indoor Fan Speed Control 
x  Indoor fan speed can be set using remote control 
12.4.1 
Fan Speed Rotation Chart 
 
12.4.2 
Automatic Fan Speed Control 
x  When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the 
table. 
o  Fan speed rotates in the range of Hi and Me. 
o  Deodorizing Control will be activated. 
 
 SHi 
Hi 
Me 
HLo 
CLo 
Lo- 
SLo 
Stop 
Hi          
Me 
         
Manual 
Lo         
Normal 
Auto  
 
 
 
 
 
 
 
QHi 
 
Hi-70 
       
QMe 
  
Me-70 
      
Manual 
QLo 
    
CLo-70 
   
Quiet 
Auto  
Hi-70 
Me-70 
 
 
 
 
 
Manual 
         
Cooling 
Powerful 
Auto 
         
Manual 
       
  
Normal 
Auto 
       
  
Manual 
       
  
Quiet 
Auto 
       
  
Manual 
       
  
Soft Dry 
Powerful 
Auto 
       
  
Mode 
Judgment 
       
  
 
x  Auto Fan Speed during cooling operation: 
Indoor fan will rotate alternately between off and on as shown in below diagram. 
At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing 
purpose. 
For the first time the compressor operates, indoor fan will be switched to Hi fan speed from Lo- after 70 
seconds from the start of compressor. This cause the room temperature to achieve the setting temperature 
quickly. 
During compressor stops, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher 
volume of refrigerant in liquid form returning to the compressor. 
After the compressor turned off for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the 
room. This is to obtain the actual reading of the intake air temperature. 
For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and 
lesser noise environment, after 70 seconds from the restarts of compressor. 
 
Fan Speed (rpm) 
Speed 
CS-C7JKD CS-C9JKD CS-C12JKD 
SHi 1050 
1170 
1150 
Hi 960 
1150 
1080 
Me 840 
930 
940 
HLo 820 
820 
840 
CLo 740 
740 
800 
Lo- 700 
700 
760 
SLo 680 
680 
740 
QHi 890 
1080 
1010 
QMe 770 
860 
870 
QLo 690 
690 
730 
32 
 
 
 
 
 
*1 
   
 
 
*2 
 
 
Lo-  Lo-  Lo- 
 
Lo- 
 
 Variable 
RPM
Indoor Fan 
 
Stop  
 
 
 
 Stop    
40” 30” 
20”  160” 
40” 30” 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compressor 
 
 
ON     OFF   
ON 
 
*1 
Fan Speed is Hi until the compressor stops (when the room temperature reaches setting 
temperature). 
*2 
Fan Speed is Me after the compressor restarts. 
 
x  Auto Fan Speed during Soft Dry operation: 
Indoor fan will rotate alternately between off and Lo-. 
At the beginning of each compressor starts operation, indoor fan will increase fan speed gradually for 
deodorizing purpose. 
When compressor turned off for 6 minutes, indoor fan will start at Lo- to circulate the air in the room. This is 
to obtain the actual reading of intake air temperature. 
 
  
 
Lo-  Lo- 
 
Lo- 
 Stop 
 
Stop 
 
Stop 
 
Indoor Fan 
 
 
 
 
 
 
 
40”  
6’ 
 40” 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compressor  
ON 
OFF 
ON 
 
12.4.3 
Manual Fan Speed Control 
x  Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control. 
x  There are 3 types of fan speed settings: Lo, Me, Hi. 
12.4.4 
Indoor Fan Motor rpm Abnormal Control 
x  Immediate after the fan motor is started, rpm abnormal control is performed every second. 
x  During fan motor on, if fan motor feedback  2550 rpm or < 50 rpm continuously for 10 seconds, the fan motor 
error counter increased; fan motor is then stopped and restarted. If the fan motor error counter increased to 7, 
then air conditioner will stop operation. 
 
12.5  Outdoor Fan Speed Control 
x  There is only one speed for outdoor fan motor. 
x  When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously. 