DOWNLOAD Panasonic CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) Service Manual ↓ Size: 40.8 MB | Pages: 126 in PDF or view online for FREE

Model
CS-BE25TKE CS-BE35TKE CS-BE50TKE CU-BE25TKE CU-BE35TKE CU-BE50TKE (serv.man2)
Pages
126
Size
40.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-be25tke-cs-be35tke-cs-be50tke-cu-be25tke-cu-be3.pdf
Date

Panasonic CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) Service Manual ▷ View online

Model 
Indoor CS-BE50TKE 
Outdoor CU-BE50TKE 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (4-poles) 
Output Power 
900 
Indoor Fan
 
Type  
Cross-Flow 
Fan 
Material  
ASG20K1 
Motor Type 
 
DC / Transistor (8 poles) 
Input Power 
47.3 
Output Power 
40 
Speed 
QLo 
Cool rpm 
900 
Heat rpm 
960 
Lo 
Cool rpm 
960 
Heat rpm 
1030 
Me 
Cool rpm 
1110 
Heat rpm 
1170 
Hi 
Cool rpm 
1260 
Heat rpm 
1320 
SHi 
Cool rpm 
1300 
Heat rpm 
1370 
Outdoo
r Fa
n
 
Type  
Propeller 
Fan 
Material  
PP 
Motor Type 
 
DC (8 poles) 
Input Power 
– 
Output Power 
40 
Speed Hi 
Cool rpm 
820 
Heat rpm 
820 
Moisture Removal 
L/h (Pt/h) 
2.8 (5.9) 
Indoor 
Airflow 
QLo 
Cool m
3
/min (ft
3
/min) 8.33 
(294) 
Heat m
3
/min (ft
3
/min) 8.93 
(315) 
Lo 
Cool m
3
/min (ft
3
/min) 8.93 
(315) 
Heat m
3
/min (ft
3
/min) 9.63 
(340) 
Me 
Cool m
3
/min (ft
3
/min) 10.43 
(368) 
Heat m
3
/min (ft
3
/min) 11.03 
(390) 
Hi 
Cool m
3
/min (ft
3
/min) 11.60 
(410) 
Heat m
3
/min (ft
3
/min) 12.50 
(440) 
SHi 
Cool m
3
/min (ft
3
/min) 12.33 
(435) 
Heat m
3
/min (ft
3
/min) 13.03 
(460) 
Outdoor 
Airflow 
Hi 
Cool m
3
/min (ft
3
/min) 32.7 
(1155) 
Heat m
3
/min (ft
3
/min) 32.7 
(1155) 
Refrigeration 
Cycle 
Control Device 
 
Expansion Valve 
Refrigerant Oil 
cm
3
 FV50S 
(450) 
Refrigerant Type 
g (oz) 
R410A, 1.34k (47.3) 
F-Gas 
GWP 2088 
C02eq (ion) Precharge Amount / 
Maximum charge Amount 
2.798 / 3.111 
Dimension 
Height (I/D / O/D) 
mm (inch) 
290 (11-7/16) / 619 (24-3/8) 
Width (I/D / O/D) 
mm (inch) 
870 (34-9/32) / 824 (32-15/32) 
Depth (I/D / O/D) 
mm (inch) 
214 (8-7/16) / 299 (11-25/32) 
Weight 
Net (I/D / O/D) 
kg (lb) 
9 (20) / 38 (84) 
10 
Model 
Indoor CS-BE50TKE 
Outdoor CU-BE50TKE 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 12.70 (1/2) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 15 × 21 
Size (W × H × L) 
mm 
610 × 315 × 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 28 × 17 
Size (W × H × L) 
mm 
36.4 × 588 × 856.3:827.7 
Air Filter 
Material  
Polypropelene 
Type  
One-touch 
Power Supply 
 
Indoor 
Power Supply Cord 
Nil 
Thermostat  
Nil 
Protection Device 
 
Nil 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
– 
Minimum °C 
16 
– 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
– 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-15 
-16 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
7. 
Maximum heating capacity shown are the values based on powerful operation. 
8. 
If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with 
rated voltage 230V shall be used. 
9. 
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 
10.  SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating 
season. Other fiche data indicates in an attached sheet. 
 
 
 
 
 
 
 
 
 
11 
3. Features 
  Inverter Technology 
o
  Wider output power range 
o
 Energy 
saving 
o
 Quick 
Cooling 
o
 Quick 
Heating 
o
  More precise temperature control 
 
  Environment Protection 
o
  Non-ozone depletion substances refrigerant (R410A) 
 
  Long Installation Piping 
o
  Long piping up to 15 meters 
 
  Easy to use remote control 
 
  Quality Improvement 
o
  Random auto restart after power failure for safety restart operation 
o
 Gas 
leakage 
protection 
o
  Prevent compressor reverse cycle 
o
  Inner protector to protect compressor 
 
  Operation Improvement 
o
  Quiet mode to reduce the indoor unit operation sound 
o
  Powerful mode to reach the desired room temperature quickly 
 
  Serviceability Improvement 
o
  Breakdown Self Diagnosis function 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12 
4. Location of Controls and Components 
4.1 Indoor 
Unit 
 
 
4.2 Outdoor 
Unit 
 
4.3 Remote 
Control 
 
 
 
 
 
POWER
TIMER
Aluminium Fin 
Auto OFF/ON button
• Use when remote control is misplaced
or malfunction occurs.
Air Filters
Front panel
Remote Control
receiver
Vertical Airflow
direction louver
• Do not adjust by hand.
Horizontal Airflow
direction louver
• Manually adjustable.
INDICATOR
POWER
(Green)
TIMER
(Orange)
ON
OFF
SET
TIMER
CANCEL
AIR SWING
TEMP
MODE
SLEEP
FAN SPEED
OFF/ON
OFF/ON
Airflow direction selection
Fan speed selection
Transmitter
Operation mode
Sleep mode operation
OFF/ON
Powerful/Quiet operation
Temperature setting
Remote control
display
Timer setting
Check
Clock setting
Page of 126
Display

Click on the first or last page to see other CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) service manuals if exist.