5. Dimensions
5.1 Indoor Unit & Remote Control
5.1.1
CS-BE25TKE CS-BE35TKE
ON
OFF
SET
TIMER
CANCEL
AIR SWING
TEMP
MODE
SLEEP
FAN SPEED
OFF/ON
OFF/ON
<Front View>
<Bottom View>
<Rear View>
<Top View>
850
41-61
410
16.4
264.6
Unit: mm
B
A
C
PIPE
HOLE
CENTER
HOLE
CENTER
PIPE
HOLE
CENTER
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
496.6
128
228
228
128
Right
piping
hole
piping
hole
Left
piping
hole
piping
hole
Installation
plate
plate
Indoor unit
external
dimensions
line
external
dimensions
line
425
425
43
95
144.5
59
87
64
<Remote Control Holder>
<Remote Control>
Gas side
Liquid side
Liquid side
Relative position between the indoor unit and the installation plate <Front View>
Right
piping
hole
piping
hole
199
290
60
41
<Side View>
Air intake
direction
direction
Air outlet
direction
direction
Left
piping
hole
piping
hole
<Side View>
22
199
99
60
99
60
14
5.1.2 CS-BE50TKE
ON
OFF
SET
TIMER
CANCEL
AIR SWING
TEMP
MODE
SLEEP
FAN SPEED
OFF/ON
OFF/ON
<Back View>
<Top View>
16.4
264.6
Unit: mm
B
A
C
PIPE
HOLE
CENTER
HOLE
CENTER
PIPE
HOLE
CENTER
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
496.6
128
241.5
241.5
128
Right
piping
hole
piping
hole
Left
piping
hole
piping
hole
Installation
plate
plate
Indoor unit
external
dimensions
line
external
dimensions
line
432
439
43
95
87
64
<Remote Control Holder>
<Remote Control transmitter>
Relative position between the indoor unit and the installation plate <Front View>
<Side View>
<Side View>
144.5
59
22
214
Air intake
direction
direction
Air outlet
direction
direction
Left
piping
hole
piping
hole
41-61
410
Liquid side
Gas side
Right
piping
hole
piping
hole
214
290
61.1
45
<Front View>
870
1~2
1~2
<Bottom View>
115
60
125
60
15
5.2 Outdoor
Unit
5.2.1
CU-BE25TKE CU-BE35TKE
<Top View>
<Front View>
<Side View>
<Side View>
Anchor Bolt Pitch
320 × 570
Space necessary for
installation
100 mm
100 mm
1000 mm
Unit : mm
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
2-way valve at Liquid side
(High Pressure)
(High Pressure)
69
.5
(18)
61.
6
542
39
289
22
(104.7)
60.5
155.
2
85.
5
34.
3
570.3
104.9
780
67.6
16
5.2.2 CU-BE50TKE
<Top View>
<Front View>
<Side View>
<Side View>
Anchor Bolt Pitch
330 × 540
Space necessary for
installation
100mm
100mm
1000mm
Unit : mm
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
2-way valve at Liquid side
(High Pressure)
(High Pressure)
22
(124 )
(62.6)
33
0
61
9
16
7
97
69
(2
0
)
62
32
540
160
824
68.7
37
299
Click on the first or last page to see other CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) service manuals if exist.