33 
10.2.1.2 CU-BE50TKE 
 
 
 
 
 
 
 
 
 
 
 
CN-HOT
CN-STM
CN-TH1
CN-MTR2
CN-MTR1
CN-TANK
AC-BLK
FG1
DATA
FG2
AC-WHT
RAT1
RAT2
POWER
TRANSISTOR
(IPM)
CURRENT
TRANSFORMER
(CT)
34 
11. Installation 
Instruction 
11.1  Select the Best Location 
11.1.1 Indoor 
Unit 
  Do not install the unit in excessive oil fume area 
such as kitchen, workshop and etc. 
  There should not be any heat source or steam 
near the unit. 
  There should not be any obstacles blocking the air 
circulation. 
  A place where air circulation in the room is good. 
  A place where drainage can be easily done. 
  A place where noise prevention is taken into 
consideration. 
  Do not install the unit near the door way. 
  Ensure the spaces indicated by arrows from the 
wall, ceiling, fence or other obstacles. 
  Recommended installation height for indoor unit 
shall be at least 2.5 m. 
11.1.2 Outdoor 
Unit 
  If an awning is built over the unit to prevent direct 
sunlight or rain, be careful that heat radiation from 
the condenser is not obstructed. 
  There should not be any animal or plant which 
could be affected by hot air discharged. 
  Keep the spaces indicated by arrows from wall, 
ceiling, fence or other obstacles. 
  Do not place any obstacles which may cause a 
short circuit of the discharged air. 
  If piping length is over the [piping length for 
additional gas], additional refrigerant should be 
added as shown in the table. 
 
 
Example: For BE20*** 
If the unit is installed at 10 m distance, the quantity of 
additional refrigerant should be 50 g .... (10-7.5) m x 
20 g/m = 50 g. 
 
 
 
 
 
 
 
11.1.3  Indoor/Outdoor Unit Installation 
Diagram 
 
 
 
  This illustration is for explanation purposes only. 
The indoor unit will actually face a different way. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Model
Horse 
Power 
(HP)
Piping size
Std. 
Length 
(m)
Max. 
Elevation 
(m)
Min. 
Piping 
Length 
(m)
Max. 
Piping 
Length 
(m)
Additional 
Refrigerant 
(g/m)
Piping 
Length 
for add. 
gas
(m)
Gas
Liquid
BE20***
3/4HP
9.52mm 
(3/8")
6.35mm 
(1/4")
5
15
3
15
15
7.5
KE25***, 
BE25***,
DE25***
5
.
7
5
1
5
1
3
5
1
P
H
0
.
1
KE35***, 
BE35***,
DE35***
5
.
7
0
2
5
1
3
5
1
P
H
5
.
1
KE50***,
BE50***,
DE50***
2.0HP
12.7mm 
(1/2")
15
3
15
20
7.5
50 mm 
or more
65 mm 
or more
(Left and right are identical)
 Vinyl tape
 
6
Remote control holder 
5
Remote 
Remote control holder fixing screws
control 
3
100 mm
or more
1000 mm 
or more
100 mm 
or more
300 mm
or more
It is advisable to 
avoid more than 2 
blockage directions. 
For better ventilation 
& multiple-outdoor 
installation, please 
consult authorized 
dealer/specialist.
Installation plate 
1
Sleeve ( )
Bushing-Sleeve ( )
Bend the pipe as 
closely on the wall as 
possible, but be careful 
that it doesn’t break.
Saddle ( )
Power supply cord ( )
Additional drain hose ( )
Gas side piping ( )
Connection cable ( )
Putty ( ) 
(Gum Type Sealer) 
Installation parts you 
should purchase ( )
Vinyl tape (wide) ( )
 
• Apply after carrying 
out a drainage test.
 
• To carry out the 
drainage test, 
and pour water into 
the heat exchanger.
remove the air filters
Liquid side piping ( )
 
• Carry out insulation after 
checking for gas leaks and 
secure with vinyl tape.
Attaching the remote control holder to the wall
Insulation of piping connections
Piping direction
Attention not to bend 
up drain hose
Right
Right 
Rear
Right 
bottom
Left 
Rear
Left bottom
Left
(Front side)
35 
11.2 Indoor Unit 
11.2.1  How to Fix Installation Plate 
The mounting wall shall be strong and solid enough to prevent it from vibration. 
 
 
 
Model 
Dimension 
2  3 4 5 6 
BE20***, 
KE25***, BE25***, DE25***, 
KE35***, BE35***, DE35*** 
480 mm 
90 mm 
425 mm 
425 mm 
43 mm 
95 mm 
 
 
 
Model 
Dimension 
2  3 4 5 6 
KE50***, BE50***, DE50*** 
490 mm 
85 mm 
439 mm 
432 mm 
43 mm 
95 mm 
 
The center of installation plate should be at more than 1 at right and left of the wall. 
The distance from installation plate edge to ceiling should more than 2. 
From installation plate center to unit’s left side is 3. 
From installation plate center to unit’s right side is 4. 
B
 
: For left side piping, piping connection for liquid should be about 5 from this line. 
 
: For left side piping, piping connection for gas should be about 6 from this line. 
1  Mount the installation plate on the wall with 5 screws or more (at least 5 screws). 
(If mounting the unit on the concrete wall, consider using anchor bolts.) 
o
 
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using 
a level gauge. 
2  Drill the piping plate hole with ø70 mm hole-core drill. 
o
 
Line according to the left and right side of the installation plate. 
The meeting point of the extended line is the center of the hole. 
Another method is by putting measuring tape at position as shown in the diagram above. 
The hole center is obtained by measuring the distance namely 128 mm for left and right hole 
respectively. 
o
 
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor 
side. 
3
4
B
A
C
Ceiling
Wall
Wall
Installation 
plate 
1
2 screw
More than 
1
More than 
1
Measuring Tape
Indoor unit
228 mm
128 mm
228 mm
128 mm
More than 
2
For best strength of 
INDOOR unit installation, 
it is highly recommended 
to locate “ ” at 5 position 
as shown. 
PIPE 
HOLE 
CENTER
PIPE 
HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
3
4
B
A
C
Ceiling
Wall
Wall
Installation 
plate 
1
2 screw
More than 
1
More than 
1
Measuring Tape
Indoor unit
241.5 mm
128 mm
241.5 mm
128 mm
More than 
2
For best strength of 
INDOOR unit installation, 
it is highly recommended 
to locate “ ” at 5 position 
as shown. 
PIPE 
HOLE 
CENTER
PIPE 
HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
128mm TO 
PIPE HOLE 
CENTER
36 
11.2.2  To Drill a Hole in the Wall and 
Install a Sleeve of Piping 
1  Insert the piping sleeve to the hole. 
2  Fix the bushing to the sleeve. 
3  Cut the sleeve until it extrudes about 15 mm 
from the wall. 
 
 
 CAUTION
 
   
           
 
 When the wall is hollow, please be sure to use the
  sleeve for tube assembly to prevent dangers 
  caused by mice biting the connection cable. 
 
4  Finish by sealing the sleeve with putty or 
caulking compound at the final stage. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Putty or caulking compound
Sleeve for 
tube assembly
Approx. 5 - 7 mm
Bushing for tube assembly
Wall
ø70 mm 
through hole
Indoor
Outdoor
15 mm
Page of 126