12.1.6. Gas charging
(After Evacuation)
 1. Connect the charge hose to the charging cylinder.
  • Connect the charge hose which you disconnected from
the vacuum pump to the valve at the bottom of the
cylinder.
 2. Purge the air from the charge hose.
  • Open the valve at the bottom of the cylinder and press
the check valve on the charge set to purge the air (be
careful of the liquid refrigerant).
 3. Open the valve (Low side) on the charge set and charge
the system with liquid refrigerant.
  • If the system cannot be charged with the specified
amount of refrigerant, it can be charged with a little at a
time (approximately 150 g each time) while operating
the air conditioner in the cooling cycle; however, one
time is not sufficient, wait approximately 1 minute and
then repeat the procedure. (pumping down-pin)
This is different from previous procedures. Because you are
charging with liquid refrigerant from the gas side, absolutely do
no attempt to charge with large amount of liquid refrigerant
while operating the air conditioner.
 4. Immediately disconnect the charge hose from the 3-
way valve’s service port.
  • Stopping partway will allow the refrigerant to be
discharged.
  • If the system has been charged with liquid refrigerant
while operating the air conditioner, turn off the air
conditioner before disconnecting the hose.
 5. Mount the valve stem caps and the service port cap.
  • Use torque wrench to tighten the service port cap to a
torque of 18 N.m.
  • Be sure to check for gas leakage.
Procedure:
61
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
 1. The Electronic Controller, a Signal Receiver and an
Indicator (Fig. 3) can be seen by the below steps:
  • Remove the 2 caps and 2 screws at the bottom of the
Front Grille. (Fig. 1)
  • Remove the Front Grille by releasing the 2 hooks at the
top of the Front Grille. (Fig. 1)
  • Remove the Control Board Cover by releasing the 2
tabs at left, 1 tab on top and 1 tab at right side of the
Control Board Cover. (Fig. 2)
 2. To remove the Electronic Controller:
  • Release the Particular Piece. (Fig. 3)
  • Release the hook that hold the Electronic Controller.
(Fig. 3)
  • Remove the Control Board by:-
  − Releasing CN-REC/DISP connectors. (Fig. 4)
  − Releasing CN-FM connectors. (Fig. 4)
  − Releasing CN-STM connector. (Fig. 4)
  − Removing the Earth Wire screw. (Fig. 4)
  − Releasing the Intake Air Sensor. (Fig. 4)
  − Releasing the Piping Sensor. (Fig. 4)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
13 Servicing Information
Caution:
  • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use
a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
  • Pb free solder will tend to splash when heated too high (about 1100° F/600°C).
13.1. Indoor Electronic Controllers Removal Procedures
13.2. Indoor Fan Motor and Cross Flow Fan Removal Procedures
62
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
  − Pulling out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
  − Removing the right and left screws. (Fig. 5)
  − Then remove the Control Board by pressing down the
hook at the left and pushing up the right hook. (Fig. 5)
  − Release the Fan Motor leadwire by pressing the hook at
the center of the connector. (Fig. 6)
  − Remove the screw at the Cross Flow Fan. (Fig. 7)
  − REMINDER - To reinstall the Fan Motor, adjust the
connector of the Fan Motor as shown in the Fig. 7.
Fig. 5
Fig. 6
Fig. 7
63
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
  − Remove the screws at the left of the Evaporator. (Fig. 8)
  − Remove the Bearing. (Fig. 9)
  − Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 9)
Fig. 8
Fig. 9