9
2.3.
CS-A12HKD  CU-A12HKD
Item
Unit
Indoor unit
Outdoor unit
Performance Test Condition 
NEW JIS
C
Capacity
kW
3.52 - 3.54
O
BTU/h
12000 - 12100
O
kcal/h
3030 - 3040
L
EER
W/W
3.26 - 3.16
I
BTU/hW
11.1 - 10.8
N
Noise Level
dB (A)
High: 39 Low: 29
High: 48 - 49
G
Power level dB
High: 52
High: 63 - 64
H
Capacity
kW
4.00 - 4.05
E
BTU/h
13640 - 13810
A
kcal/h
3440 - 3480
T
Cop
W/W
3.67 - 3.62
I
BTU/hW
12.5 - 12.3
N
Noise Level
dB (A)
High: 40 Low: 29
High: 48 - 49
G
Power level dB
High: 53
High: 64 - 65
Moisture Removal
l/h
2.0
(pt/h)
4.2
Air Volume
Lo
m
3
/m (ft
3
/m)
Cooling; 6.1 (220)
Heating; 6.5 (230)
Me
m
3
/m (ft
3
/m)
Cooling; 8.5 (300)
Heating; 8.5 (300)
Hi
m
3
/m (ft
3
/m)
Cooling; 9.9 (350)
Heating; 10.0 (350)
Cooling;
32.5 (1150) - 33.0 (1160)
SHi
m
3
/m (ft
3
/m)
Cooling; 10.1 (360)
Refrigerant Control Device
Capillary Tube
Refrigerant Oil (Charged)
cm
3
ATMOS NM56M or
SUNISO 4GDID (350cm
3
)
Refrigerant (Charged) R22
kg (oz)
1.01 (35.7)
Dimension
Height
mm (inch)
280 (11 - 1/32)
540 (21 - 9/32)
Width
mm (inch)
799 (31 - 15/32)
780 (30 - 23/32)
Depth
mm (inch)
183 (7 - 7/32)
289 (11 - 13/32)
Net Weight
kg (lbs)
9 (20)
34 (75)
Pipe Diameter
Gas
mm (inch)
12.70 (1/2”)
Liquid
mm (inch)
6.35 (1/4”)
Height Difference
m (ft)
5 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 15 (49.2)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Refrigeration Charge Less
m (ft)
7.5 (24.6)
Drain Hose
Inner diameter
mm
16
Length
mm
650
Compressor
Type
Rotary (1 cylinder)
rolling piston type
Motor Type
Induction (2-poles)
Rated Output
W
950
Fan
Type
Cross-flow Fan
Propeller Fan
Material
ASG20K1
PP Resin
Motor Type
Induction (4-poles)
Induction (6-poles)
Input power
W
42 - 47
64 - 73
Output power
W
15
31
Fan Speed
Lo (Cool / Heat)
rpm
800 / 860
Me (Cool / Heat)
rpm
1120 / 1120
Hi (Cool / Heat)
rpm
1300 / 1320
845 - 860 / —
SHi (Cool / Heat)
rpm
1320 / —
10
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note:
• Specification are subjected to change without prior notice for further improvement.
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugate Fin
Row 
× Stage × FPI
× 15 × 21
× 24 × 17
Size (W 
× H × L)
mm (inch)
610 
× 315 × 25.4
36.38 
× 504 × 713:684
Air Filter Type
Material
Polypropelene
Style
One-touch
 Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V 220
230
Hz
50
50
Input power
Cooling
W
1.08
1.12
Heating
W
1.09
1.12
Starting Current
A
20
20
Running Current
Cooling
A
5.1
5.1
Heating
A
5.2
5.1
Maximum Current
A
6.0
6.0
Power Factor
Cooling
%
96
95
Heating
%
95
95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm)
Length
m (ft)
2 (6)
Thermostat
Protection Device
Overload Protector
Item
Unit
Indoor unit
Outdoor unit
11
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
- Patrol Sensor color changes to indicate the dirt level in the air
• Long Installation Piping
- CS/CU-A7HK, CS/CU-A9HK, long piping up to 10 meter
- CS/CU-A12HK, long piping up to 15 meter
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect Compressor
- Noise prevention during soft dry operation
Blue Coated Condenser for high resistance to corrosion
• Operation Improvement
Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Outdoor Unit