CS-A9HKD  CU-A9HKD
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-A7HK
CS-A9HK
CONNECTION
CWA921373
BLUE-YELLOW
390.0 
Ω
YELLOW-RED
394.0 
Ω
MODEL
CU-A7HK
CU-A9HK
CONNECTION
CWA951526
BLUE-YELLOW
309 
Ω
YELLOW-RED
210 
Ω
MODEL
CU-A7HK
CU-A9HK
CONNECTION
2RS122D5BG02
2PS156D3BB02
C - R
5.193 
Ω
3.501 
Ω
C - S
5.557 
Ω
3.405 
Ω
19
8.2.
CS-A12HKD  CU-A12HKD
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-A12HK
CONNECTION
CWA921373
BLUE-YELLOW
390.0 
Ω
YELLOW-RED
394.0 
Ω
MODEL
CU-A12HK
CONNECTION
CWA951117J
BLUE-YELLOW
230 
Ω
YELLOW-RED
255 
Ω
MODEL
CU-A12HK
CONNECTION
2PS206D2BA02
C - R
3.207 
Ω
C - S
3.256 
Ω
20
9 Electronic Circuit Diagram
Page of 78
Display