DOWNLOAD Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual ↓ Size: 8.35 MB | Pages: 97 in PDF or view online for FREE

Model
CS-A75KE CS-A95KE CS-A125KE CU-A75KE CU-A95KE CU-A125KE
Pages
97
Size
8.35 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-a75ke-cs-a95ke-cs-a125ke-cu-a75ke-cu-a95ke-cu-a.pdf
Date

Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual ▷ View online

1
Press the clock button
2
Press to set the current time
Press continuously for fast forwarding.
Press continuously for fast reversing.
3
Press the clock button
Can be used for approximately one year.
Observe the following when replacing the batteries
Replace with new batteries of the same type .
Do not use rechargeable batteries (Ni-Cd).
Remove the batteries if the unit is not going to be used for a long period.
lights up
PM
PM
1
OPEN
Slide the cover to open
2
Be sure the directions are correct
Open the remote control
cover and confirm the
display 12:00 PM
is flashing.
PM
Setting the clock
About the batteries
*
Set the current time (Clock) immediately to prevent battery exhaustion.
flashes
lights up
lights up
Remote Control
Inserting batteries
AIR SWING
TIMER
CLOCK
1
2
3
COOL
PM
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
OPEN
41
CS-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
AIR SWING
TIMER
CLOCK
1
2
3
CO
OL
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
CANCEL
SLEEP
SET
POWERFUL
OFF/ON
COOL
TEMP
HOW TO OPERATE
Automatic, Cooling, Soft Dry, Fan
Display
Close the Cover
a
FAN
DRY
COOL
HI
AUTO
AUTO
LO
AUTO
– Automatic Operation
At the start of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected
according to the  indoor temperature.
The operation mode changes every hour, when
necessary.
Temperature is not displayed on remote control during
Auto mode operation.
Operation details
           Cooling Operation
To set room temperature to your preference of cooling
comfort.
Setting
temperature
Soft Dry operation with Low
fan speed
Switch to Soft Dry when setting temperature is
reached.
Cooling
Operation
DRY
COOL
COOL
          – Soft Dry Operation
A very gentle Cooling Operation. Consisting primarily of
dehumidifying. It does not lower the room temperature.
During Soft Dry operation, the indoor fan operates at Low fan
speed.
DRY
1
Press to select the desired operation mode
When pressed, the display changes in this order.
2
Press to start the operation
POWER indicator LED (Green) on indoor unit will light up.
Press once more to stop operation.
3
Press to select room temperature
• 
a
 Automatic Operation
Display
- Operation with 2°C higher than standard temperature.
- Operation with standard temperature.
- Operation with 2°C lower than standard temperature.
        Heating,             Cooling,           Soft Dry operation
Press to increase temperature by 1°C.
Press to decrease temperature by 1°C.
The temperature can be set between 16°C and 30°C.
Recommended temperature
For Heating: 20°C - 24°C.
For Cooling: 26°C - 28°C.
For Soft Dry: 1°C - 2°C lower than room temperature.
HEAT
42
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
Adjusting Airflow Direction And Fan Speed
Operation details
*
Five stages of adjustments can be made in
this range.
Louver adjustment range
Press to select Fan speed
The display changes in this order
Automatic
Low
Medium
High
Selecting Vertical Airflow Direction
Press AUTO,
Selecting Vertical Airflow Direction
Press AUTO,
Cooling and Soft Dry – The louver swing up
and down automatically.
Heating – When the discharge air
temperature is low such as at the start of
heating operation, the air blows at
horizontal level. As the temperature rises,
the hot air blows in a downwards direction.
To stop the automatic airflow direction
operation,press  MANUAL  button.
Press MANUAL
Manual selection of Vertical Airflow Direction
Louver.
The display changes in this order.
Horizontal Airflow Direction
Adjust it manually.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
AIR SWING
TIMER
CLOCK
1
2
3
COOL
AUTO FAN
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
Air Circulation
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
Cooling
Soft Dry
           – Heating Operation
Defrosing Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor unit.
Heat is obtained from outdoor air to warm up the room. When
the outdoor ambient air temperature falls, the heating capacity
of the unit might be reduced.
We recommend that you use an additional heating device
when the outdoor ambient air temperature is low.
Automatic Airflow Volume
The speed of the Indoor fan is adjusted automatically
according to the operation. The Indoor fan stops occasionally
during cooling operation.
HEAT
43
CS-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
AIR SWING
TIMER
CLOCK
1
2
3
COOL
ON
AM
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON
OFF
SET
CANCEL
SLEEP
SETTING THE TIMER
1
Press ON-TIMER
Flashes 
Set the ON-TIMER to 7:00AM
2
Press to set the time
Increase by 10 minutes
Decrease by 10 minutes
*
Press continuously for quick
setting.
Ensure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing.
Timer Cancellation Button
(To cancel the Timer)
Press the ON-TIMER or OFF-TIMER then press
CANCEL.
*
The timer indicator on the indoor unit will go off.
To change the setting time, follow  the above steps.
AM
ON
Timer details
When the ON-Timer is set, operation will start before the actual set time. This is to allow the room temperature to
reach the setting temperature by the setting time (Cooling and Soft dry, 15 minutes in advance. Heating and
Automatic, 30 minutes in advance).
Once the ON-Timer is set, operation will start at the setting time everyday.
3
Press SET
Lights up 
 
*
The timer indicator
(orange) on the
indoor unit will light
up.
AM
ON
4
To set the OFF-TIMER
Press the OFF-TIMER then follow
steps 2 and 3 as above.
44
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
Page of 97
Display