SELECT THE BEST LOCATION
INDOOR UNIT
  • There should not be any heat source or steam near the
unit.
  • There should not be any obstacles blocking the air
circulation.
  • A place where air circulation in the room is good.
  • A place where drainage can be easily done.
  • A place where noise prevention is taken into
consideration.
  • Do not install the unit near the door way.
  • Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
OUTDOOR UNIT
  • If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
  • There should not be any animal or plant which could be
affected by hot air discharged.
  • Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
  • Do not place any obstacles which may cause a short
circuit of the discharged air.
  • If piping length is over the rated length, additional
refrigerant should be added as shown in the table.
Indoor/Outdoor Unit Installation Diagram
Attached accessories
41
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Installation on the ceiling
9.2. INDOOR UNIT
9.2.1. SELECT THE BEST LOCATION
(Refer to “Select the best location” section)
9.2.2. HOW TO FIX INSTALLATION PARTS
  • Measure and mark the position for the Suspension bolts and the piping hole.
  • Drill the hole for anchor nut on the ceiling.
  • Drill the Piping hole slightly tilted to the outdoor side with a Ø 70 hole-core drill.
  • Insert the nuts and washers onto the suspension bolts for locking the Suspension bolts on the ceiling.
  • Mount the suspension bolts to the anchor-nuts firmly as shown in the diagram.
Installation on the wall
The centre of installation plate should be at more than 710 mm at right and left of the wall.
The distance from installation plate edge to floor should more than 425 mm.
From installation plate left edge to unit’s left side is 76 mm.
From installation plate right edge to unit’s right is 76 mm.
 1. Mount the installation plate on the wall with 3 screws or more.
(If mounting the unit on the concrete wall consider using anchor bolts.)
  • Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge.
 2. Drill the piping plate hole with ø70 mm hole-core drill.
  • Drill the piping hole slightly slanted to the outdoor side.
42
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
 1. Insert the piping sleeve to the hole.
 2. Fix the bushing to the sleeve.
 3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass’y to prevent dangers caused by
mice biting the connecting cable.
 4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
Indoor unit installation
1. Remove the Front Grille.
  • Remove 2 screws
from the left and right corners.
  • Pull the upper left and right side of the intake grille
toward you, and it will stop at slightly tilted position.
  • Remove 2 screws
.
  • Remove 3 screws cap, then remove 3 screws
.
  • Release 3 hooks as shown in the diagram.
  • Lift up the front grille.
2a. For installation on the ceiling.
2b. For installation on the wall.
9.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
9.2.4. INDOOR UNIT INSTALLATION
43
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Piping and Drainage
9.2.5. CONNECT THE CABLE TO THE INDOOR UNIT
 1. Open the control box at the bottom end of the chassis and connect the cable through the hole.
  • Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
  • Ensure the color of wires of outdoor unit and the terminal Nos are the same to the indoor’s respectively.
  • Secure the cable onto the control board with the holder (clamper).
  • Insert two tabs on the Side panel into two slots on the chassis, and secure it to the chassis with the screw.
9.2.6. PIPING AND DRAINAGE
  • Cut off the Chassis with a nipper according to the inner surface for the Pipings.
  • Align the center of the pipings and sufficiently tighten the flare nut with fingers.
  • Finally tighten the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
  • Wrap the tube joining areas with insulating material so that there are no gaps (if it overlaps, cut the excess material) refer
diagram in "Pipe formings, insulating and finishing".
  • Connect the drain hose (insulated) to the drain outlet.