DOWNLOAD Panasonic CS-A12CTP / CU-A12CTP5 / CS-A18CTP / CU-A18CTP5 / CS-A24CTP / CU-A24CTP5 Service Manual ↓ Size: 8.15 MB | Pages: 73 in PDF or view online for FREE

Model
CS-A12CTP CU-A12CTP5 CS-A18CTP CU-A18CTP5 CS-A24CTP CU-A24CTP5
Pages
73
Size
8.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-a12ctp-cu-a12ctp5-cs-a18ctp-cu-a18ctp5-cs-a24ct.pdf
Date

Panasonic CS-A12CTP / CU-A12CTP5 / CS-A18CTP / CU-A18CTP5 / CS-A24CTP / CU-A24CTP5 Service Manual ▷ View online

Cooling Operation Time Diagram
21
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Compressor Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
7.2. Soft Dry Mode Operation
  • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
  • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
  • The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.
  • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
  • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
  • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
  • Same as Compressor Protection Control for Cooling Mode Operation.
  • Same as Anti-Dew Formation Control for Cooling Mode operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
  • Fan speed rotates at Lo- speed.
22
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Soft Dry Operation Time Diagram
23
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Heating in operation according to Remote Control setting.
Time Delay Safety Control
30 minutes Time Save Control
Overload Protection Control
Compressor Reverse Rotation Protection Control
7.3. Heating Mode Operation
  • When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
  • When the setting temperature is reached during heating operation, the compressor stops and it will not start for 4 minutes.
  • The compressor will start automatically if it has stopped for 30 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
(a) Outdoor Fan Control
  • A12CT
If the temperature of the indoor heat exchanger rises to 51°C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49°C.
  • A18CT, A24CT
If the temperature of the Outdoor Heat Exchanger less than -3°C, Outdoor Fan is ON. The Outdoor Fan stop, when Outdoor
Heat Exchanger temperature is T
b
or more according to Outdoor Air Temperature region as table below:
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49°C.
During starting of Heating mode and after deice, Outdoor Fan ON for 90 sec.
(b) Compressor high pressure protection
  • If the indoor heat exchanger becomes 65°C (A12CTP); 68°C (A18CTP & A24CTP) or more, the compressor will stop and
restart automatically.
(Time Delay Safety Control - 4 minutes waiting).
  • If the compressor is operating continuously for 5 minutes or longer and temperature difference between intake air and indoor
heat exchanger is 5°C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).
▲ T = Indoor heat exchanger temperature - intake air temperature.
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
24
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Page of 73
Display