DOWNLOAD LG WT-E1275TP Service Manual ↓ Size: 2.31 MB | Pages: 71 in PDF or view online for FREE

Model
WT-E1275TP
Pages
71
Size
2.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wt-e1275tp.pdf
Date

LG WT-E1275TP Service Manual ▷ View online

57
ERROR DECISION
CAUSE FOR ERROR
BASIS
OCCURRENCE
REMEDY
ERROR
• Water Pressure Switch
is off.
PRESSURE
SENSOR
OVER 
FLOODING
ERROR
MOTOR
ERROR
• Connector the PRESSURE S/W
ASM or RED(ORANGE or PINK) 4
pin connector to P.W.B ASM has
bad connection.
• PRESSURE S/W is bad.
• Check water leakage or 
whether the drain hose is hung
on to drainage which is 0.9 m
obove from floor.
• Check blockage of air hole or 
air tube.
• Check & repair air leakage at
the air hole of outer tub the air 
tube or connection parts.
• Connector the HALL Sensor or
Natural 6 Pin connector to P.W.B
ASM had bad connection .
• Connector the stator ASM, and
YELLOW(GREEN) 3 Pin or
Natural 6 Pin connector to P.W.B
ASM had bad connection
• Hall sensor is bad.
• Locked by Bearing Housing 
• Correct the connector contact.
• Replace PRESSURE S/W ASM.
• Hang drain hose which is 
minimum 0.9m above from floor.
• Replace pressure sensor
switch
• Remove the foreign objects in
pressure sensor switch 
• Correct the connect contact.
• Change Stator ASM.
• Change Bearing Housing ASM.
• Change P.W.B ASM.
• Change Stator ASM.
58
4-8.  HOW TO DIAGNOSE AND REPAIR BY SYMPTOM
1) Washer is not energized.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Household Power supply
1. Check whether connection between
the plug and the electrical is poor
2.  Measure voltage of the electrical.
Wiring of the Washer
1. Measure resistance between both 
ends of the power supply cord with 
both the plug pins short-circuited.
2. Check whether every connector in 
the bundle of connectors has a 
good connection.
3. Check resistance of every wire to 
find out a open wire.
Electrical component
1. Check resistance with  power relay 
switch turned on
2. Check the secondary voltage of the 
transfomer.
3. Check whether the fuse is open.
Controller
If there are no defects in the above, 
it should be defect of the controller.
Poor
Around rating
0V
Less than 1
Male & female
connectors
separated
Less than 0.5
More than 1.0
10~14V
0V
Open
Over 120%
voltage than 
rating check
Defect of the 
electrical
No defect
Defect of household
power supply
No defect
Open circuit of the
power supply cord
Poor connection.
Wire is opened.
No defect
Poor contact
No defect
Coil is open
Defect of the fuse
Change the electrical.
Call for power supply 
company
Change the power 
supply cord.
Remove the cause to 
give strain and 
reconnect them.
Change the lead wire.
Change the Auto Off 
Switch
Change the
transfomerformer.
Change the fuse.(time
delay type) CAUTION
Check the fuse rating
AC220~240V:250V   8A
(AC100~127V : 125V 12A)
Change the controller
if all the electrical parts 
have no defects.
59
2) Defects on displaying function
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Main voltage
1. Measure mains voltage at the wall 
outlet
2.  Meaure voltage at the extended 
outlet that the washer is plugged in 
if the extended outlet is used and 
voltage at the electrical outlet
is normal in the above.
Controller
1. Defect of LED.
2. Defect of LED driving circuit.
3. Defect of micom.
Less than 85%
of the rating.
Less than 85%
of the rating
Low voltage. 
The dia of the lead 
wire is smaller or 
many loads are 
connected at the 
same outlet
Defect of controller.
To explain that it is 
caused by low voltage in 
electric supply and
recommend using a 
transfomer if voltage has
been continuously low.
To use a transfomer 
having a enough
capacity if using 
a transfomer.
Change the controller.
3) Reset During operation
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Mains Voltage
1. Measure voltage of the outlet that the 
washer is plugged into during wash and 
spin.
2. Reset symptom happens at specific 
time zone repeatedly.
3. Check whether a transfomerlent
power cut happens.
(Fluorescent lamp is 
transfomeriently blinked.)
Less than 
80% of the rating.
Mains voltage is too
low or size of a lead
wire is too small.
External noise 
inrushed.
Explain that it is caused 
by low voltage in electric 
mains and recommend
using a suitable size of
leads.
Explain it is caused by 
using environment.
(It happens when 
equipment with high 
frequency is used 
around)
Explain it is a problem of 
electric supply 
environment.
60
4) Water doesn’t come into the wash tub.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Inlet Valve
1. If water doesn’t come though the 
inlet valve works(electric sound 
occurs)
1) Check whether water mains is cut.
2) Check whether tabs are turned on.
3) Hot & cold tab are opposite
connected.
4) Wrongly select water temperature
option.
5) If there are no problems in the 
above, check the inlet valve filters 
after disconnecting the water supply
hoses.
6) If there are no problems in the 
above a diaphragm hole in the valve
is blocked  by foreign substance or 
the plunger in it is locked.
2. If the inlet valve doesn’t work(there 
is no electric sound)during filling 
cycle.
1) Check whether it’s connectors are 
taken off or they have poor 
connection. 
2) Check resistance of the inlet valve.
Water mains cut.
Don’t tumed on.
Connected
opposite.
Selected 
opposite.
Filters blocked
by foreign
substance.
A connector is
taken off.
Mains cut. 
Mistake of use.
Wrong installation.
Mistake of use.
Don’t clean.
Defect of the
inlet valve.
Defect of contact.
Coil is open
Explain.
Turn on the tap.
Correct their locations
and turn on the tap.
Explain how to use. 
Clean them by brush 
and explain cleaning 
regulary them.
Change the inlet valve.
Reconnect it or remove
the causes to make poor 
connection.
Change the inlet valve.
3) Reset During operation
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Controller
1. If mains voltage and the drain motor 
have no defects a defect of the 
controller is highly possible.
Change the controller.
Page of 71