LG WD1316AD7 Service Manual ▷ View online
45
Result
Wash Thermistor
Test Points
(1) to (2)
Result
(tolerance ±5%)
39.5 kΩ
26.1 kΩ
12.1 kΩ
26.1 kΩ
12.1 kΩ
8.5 kΩ
3.8 kΩ
2.8 kΩ
3.8 kΩ
2.8 kΩ
Remarks
At 86°F (30°C)
At 104°F (40°C)
At 140°F (60°C)
At 158°F (70°C)
At 203°F (95°C)
At 140°F (60°C)
At 158°F (70°C)
At 203°F (95°C)
At 221°F (105°C)
Steam generator Thermistor
Test Points
(1) to (2)
Result
(tolerance ±5%)
39.5 kΩ
26.1 kΩ
12.1 kΩ
26.1 kΩ
12.1 kΩ
8.5 kΩ
3.8 kΩ
2.8 kΩ
2.1 kΩ
1.4 kΩ
1.0 kΩ
0.7 kΩ
0.4 kΩ
3.8 kΩ
2.8 kΩ
2.1 kΩ
1.4 kΩ
1.0 kΩ
0.7 kΩ
0.4 kΩ
Remarks
At 86°F (30°C)
At 104°F (40°C)
At 140°F (60°C)
At 158°F (70°C)
At 203°F (95°C)
At 140°F (60°C)
At 158°F (70°C)
At 203°F (95°C)
At 221°F (105°C)
At 241°F (116°C)
At 266°F (130°C)
At 293°F (145°C)
At 320°F (160°C)
At 356°F (180°C)
At 293°F (145°C)
At 320°F (160°C)
At 356°F (180°C)
46
10. DISASSEMBLY INSTRUCTIONS
Be sure to unplug the machine before disassembling and repairing the parts.
CONTROL PANEL
1 Unscrew 2 screws on the back of the top plate.
2 Pull the top plate backward and upward as
2 Pull the top plate backward and upward as
shown.
3 Disconnect the Display PWB assembly
connector from the cabling.
4 Pull out the drawer and unscrew 2 screws.
5 Remove one screw.
6 Lift the side the control panel assembly and
6 Lift the side the control panel assembly and
pull it out.
7 Unscrew the 8 screws from the control panel
assembly.
8 Disassemble the display PWB assembly.
TOP PLATE ASSEMBLY
CONTROL PANEL ASSEMBLY
DRAWER
CONTROL PANEL ASSEMBLY
DISPLAY PWB ASSEMBLY
47
MAIN PWB ASSEMBLY
Disconnect the POWER connector and
the pressure switch assembly.
Remove the protective cover.
the pressure switch assembly.
Remove the protective cover.
Unscrew 1 screw on the back.
Remove the main PWB.
Remove the main PWB.
Disconnect the connectors.
PROTECT COVER
1
2
3
4
5
5
48
Unscrew the nut at the lower part of the dispenser.
Disassemble the top plate assembly.
Pull out the drawer.
Push out the DISPENSER ASSEMBLY after
Pull out the drawer.
Push out the DISPENSER ASSEMBLY after
unscrew 2 screws.
Unscrew a screw from the TOP BRACKET.
Disassemble two connectors from the POWER
Disassemble two connectors from the POWER
CORD.
Wire Color
5
Disassemble the 4 connectors from the valves.
6
Unscrew 2 screws from the back of the cabinet.
1
2
3
4
3
4
5
Blue Housing (YL-BK)
Red Housing(VT-BK)
White Housing(WH-BK)
Blue Housing(GY-BK)
White Housing(WH-BK)
Blue Housing(GY-BK)
Red Housing(BL-BK)
5
Click on the first or last page to see other WD1316AD7 service manuals if exist.