Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up Hall Sensor slowly as shown in picture.
1) Adjust the hole of Hall Sensor to
the hooks of stator as shown in red circle.
2) Push down the Hall sensor,
and assemble to the hook securely.
Caution
If you disassemble by force,not following the directions,
the hooks of stator(red circled) might break.
In this case, you need to replace the stator assembly.
So disassemble cautiously.
the hooks of stator(red circled) might break.
In this case, you need to replace the stator assembly.
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A
32
Check if there is some water on the base ?
Some part have broken.(ex. Tub,
dispenser, inlet hose, circulation
hose, steam generator, pump,
drain hose)
dispenser, inlet hose, circulation
hose, steam generator, pump,
drain hose)
Replace the broken part.
YES
Check if there is some water on the base ?
YES
Assemble the safety switch.
Reconnect or repair the connector.
Or replace the harness.
Or replace the harness.
NO
NO
NO
Replace the safety switch.
NO
Water Leakage (AE)
Is the connector connected correctly to the main PCB
and the safety switch?
Or is the harness right?
and the safety switch?
Or is the harness right?
Is safety switch assembled correctly to
the base?
the base?
When you press and hold the styrofoam
in the safety switch, is AE displayed?
in the safety switch, is AE displayed?
YES
YES
33
Dry Heater Error (dHE)
Is the Connector connected correctly to
the Main PCB and the Dry Heater or Fan Motor?
Or is the
the Main PCB and the Dry Heater or Fan Motor?
Or is the
Harness
alright?
Reconnect or repair the Connector.
Or replace the Harness.
Or replace the Harness.
Replace the Thermistor.
Is the resistance of t.he Thermistor out of range
2.5 ~ 180KΩ at 105 ~ 0°C?
2.5 ~ 180KΩ at 105 ~ 0°C?
YES
Disassemble the Dry Fan Assy and Dry Duct Upper,
and clean foreign object in Duct and Fan.
and clean foreign object in Duct and Fan.
Check for Dry Heater trouble.
Page 34
Check for Dry Fan Motor trouble.
Page 35
YES
NO
NO
NO
34
Dry Heater Trouble
After power off, is the resistance of Dry Heater out of
range 33 ~ 37Ω?
range 33 ~ 37Ω?
Is Thermostat closed ?
When checking voltage between connectors(1,2)
on drying, is the voltage AC 220-240V as the figure ?
on drying, is the voltage AC 220-240V as the figure ?
YES
YES
Replace the Dry Heater.
NO
Replace the Thermostat.
NO
Replace the PWB assembly (main).
NO