41
No Steam
1)
040
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
XXX
2)
001
XXX
VIEWING DATA
Reference to check the Steam Function
1. When inlet water press do not enough and Dry Heater break 
down, Steam is not generated.
2. Check the Data View After 3minute After Steam Function start, 
then we can see Failure cause.
1) Data View Type : Touch and Hold Pre Wash and Temp. key simultaneously, and then turn the knob until it 
display ‘040’.
2) Steam Sensor status : If it displays ‘000’, normal, ‘001’, means that ‘IE’ error and refer to page 22, ‘002’, means 
that ‘dHE’ error and refer to page 33.
How to check The Steam Function
Key
Key
Knob
Pre Wash
Spin
42
      
    !"  # $#% & '( # '(  $#)( #**%
+ +# ,#-" +(" '**-.
         
 #
'-
/  # 0 1
/ 1 # 0 
2 Ω
2 Ω
1
1
0
/
9. PART INSPECTION
When checking the resistance of the component, be sure to turn the power off, 
and do voltage discharge sufficiently.
43
9-2. DOOR LOCK SWITCH ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB / Wiring Diagram
MAIN PWB
Vdc
Vac
MICOM
12V
12V
4
1
3
2
4
1
3
2
Relay
Relay
NA4
1
2
3
4
1
2
3
4
2
3
4
PTC
PTC
Door switch
SOLENOID
5
YL
BL
RD
BK
AC
Common
terminal
of Valve
Function
The Door Lock Switch Assembly consists of a Heating PTC, a Bimetal,
a Protection PTC, and a Solenoid. It locks the door during a wash cycle.
1. Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2~4’s
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven,
force the system to the off position through CAM.
Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will
make the door lock.
- Door lock is detected when switches in terminal 4~5 are set closed.
CAM rotation will forcibly clear off the connection.
The maximum, allowable number of impulse authorizations is 2.
Upon the third authorization of the impulse, the position of CAM goes
back to the door-open position.
- Authorizing the impulse occurs in 4.5 seconds upon input for max
performance and two authorization processes are allowed at most.
Normal operation period of PTC heating: 1.5 – 5 seconds.
(Defects from the development process.)
2. Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations after
authorizing the impulse from the terminal 3 ~ 4 and the power turns 
off – maximum of 3 times of the authorizing period.
- Upon the fourth authorization of the impulse, the position of CAM goes
back to the door-close position.
44
Test
points
Result
Test Points
(2) to (4)
(3) to (4)
(4) to (5)
(2) to (4)
Result
700-1500 Ω
60-90 Ω
Infinity
120 Vac
Remarks
At 77
¡F 
(25
¡C
)
At 77
¡F 
(25
¡C
)
Voltage Input
(2)
(3)
(4)
(5)