LG MC-7682W Service Manual ▷ View online

5-17
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective P.C.B
assembly
Replace P.C.B
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the
unit)
Abnormal
normal
Defective high
voltage
transformer.
Replace high
voltage
transformer .
Check H.V.
transformer.
normal
normal
Abnormal
Defective high
voltage Diode.
Replace high
voltage Diode.
Check H.V.
diode.
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check H.V.
capacitor.
Abnormal
Defective
magnetron.
Replace
magnetron .
Check
Magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run
(Display operates properly)
5-18
(TROUBLE 7) Grill
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.  
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.  
Replace.  
1. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.  
Replace.  
(TROUBLE 6) Oven does not cook properly when programmed for the set power level 
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.  
NOTE: * Make sure the wore leads correct position.
* When removing the wire leads from parts be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.
MEASUREMENT WITH OUTER CASE
REMOVED
• When you replace the magnetron, measure for
microwave energy leakage before the outer case is
installed and after all necessary components are
replaced or adjusted.
Special care should be taken in measuring the
following parts. (Circled area of below Fig.)
- Around the magnetron
- The waveguide
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
• After all components, including the outer case, are fully
assembled, measure for microwave energy leakage
around the door viewing window, the exhaust opening,
and air inlet openings.
• Microwave energy leakage must not exceed the values
prescribed below.
NOTE: Leakage with the outer case removed less than
5 mW/cm.sq. Leakage for a fully assembled
oven (Before the latch switch (primary) is
interrupted) with the door in a slightly opened
position-less than 2 mW/cm.sq.
NOTES WHEN MEASURING
• Do not  exceed meter full scale deflection.
• The test probe must be removed no faster than  
1 inch/sec (2.5 cm/sec) along the shaded area,
otherwise a false reading may result.
• The test probe must be held with the grip portion of the
handle.
A false reading may result if the operator's hand is
between the handle and the probe.
• When testing near a corner of the door, keep the probe
perpendicular to the surface making sure the probe
horizontally along the oven surface, this may possibly
cause probe damage.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
• After adjustment and repair of any microwave energy
interruption or microwave energy blocking device,
record the measured values for future reference. Also
enter the information on the service invoice.
• The microwave energy leakage should not be more
than 4 mW/cm.sq. after determining that all parts are in
good condition, functioning properly and genuine
replacement parts which are listed in this manual have
been used.
• At least once a year, have the electromagnetic energy
leakage monitor checked for calibration by its
manufacturer.
WARNING : AVOID CONTACTING ANY    
HIGH VOLTAGE PARTS
5-2
• Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting
with a load of (1000 ± 5)g potable water.
• The water is contained in a cylindrical borosilicate
glass vessel having a maximum material thickness
of 3 mm and an outside diameter of approximately
190 mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (±1) of the water is (10±2)°C.
It is measured immediately before the water is
added to the vessel. After addition of the water to
the vessel, the load is immediately placed on the
center of the shelf which is in the lowest position and
the microwave power switched on.
• The time T for the temperature of the water to rise
by a value 
T of (10±2)°K is measured, where T is
the time in seconds and 
T is the temperature rise.
The initial and final water temperatures are selected
so that the maximum difference between the final
water temperature and the ambient temperature is
5°K.
• The microwave power output P in watts is calculated
from the following formula:
P =
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included.
• The water is stirred, to equalize temperature
throughout the vessel, prior to measuring the final
water temperature.
• Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
WATER LOAD
TURNTABLE
MEASUREMENT OF MICROWAVE POWER OUTPUT
DISASSEMBLY AND ADJUSTMENT
A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2)  Remove  the  screws  from  the  rear  and  along  side
edges of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD REMOVAL
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the earth terminal.
CAUTION: DISCHARGE THE HIGH VOLTAGE 
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
C. CONTROLLER ASSEMBLY REMOVAL
1) Disconnect the leadwire from the PCB SUB ASS’Y.
2) Remove the screws for the earth and securing the
control panel.
3) Lift control panel ASS’Y from the oven by the tab
unhooked.
5-3
4187 X (
T) + 0.88 X (T
- T
0
) X M
T
• T
2
: Temperature after heating
• T
0
: Temperature of bowl
• M: Weight of bowl