D. DOOR GROSS ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover very carefully with a    flat-
blade screwdriver.
CAUTION : Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 5 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
E. HIGH VOLTAGE TRANSFORMER 
REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from magnetron, high voltage
transformer, and capacitor.
3) Remove the screw holding the high voltage
transformer to the baseplate.
F. AIR DUCT ASSEMBLY REMOVAL
1) Disconnect the leadwire from lamp and MGT
thermostat.
2) Remove the mounting screw to the magnetron.
G. MAGNETRON REMOVAL
1) Disconnect the leadwire from the high voltage
transformer and high voltage capacitor.
2) Carefully remove the mounting screws holding the
magnetron and the waveguide.
3) Remove the magnetron ASS’Y until the tube is
clear from the waveguide.
NOTE:
1. When removing the magnetron, make sure its
dome does not hit any adjacent parts, or it may be
damaged.
2. When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and
be sure that the gasket is in good condition.
3. After replacing the magnetron, check for microwave
leakage with a survey meter around the
magnetron. Microwave energy must be below the
limit of 5 mW/cm
2
. (With a 275 ml. water load).
Make sure that gasket is rigidly attached to the
magnetron. To prevent microwave leakage,
tighten the mounting screws properly, making sure
there is no gap between the waveguide and the
magnetron.
5-4
Magnetron
Air Duct
5-5
H. FAN MOTOR ASSEMBLY REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, noise filter
and high voltage capacitor.
3) Remove the two screws holding the the suction guide
ASS’Y to the oven cavity and remove the high voltage
diode earth screw.
4) Remove the screw of the capacitor bracket.
5) Remove the two screws holding the fan motor ASS’Y
to the suction guide ASS’Y.
I. HIGH VOLTAGE CAPACITOR AND
DIODE REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, noise filter
and high voltage capacitor.
3) Remove the screw holding the suction guide ASS’Y to
the oven cavity and remove the high voltage diode
earth screw.
4) Remove the screw holding the high voltage capacitor
bracket.
J. THE TURNTABLE MOTOR REMOVAL 
1) Remove the turntable.
2) Remove the turntable shaft VERY CAREFULLY
with a slotted screwdriver.
3) Lay the unit down on its back.
4) Remove the turntable motor cover.
The turntable base cover is easily removed by
pinching the six parts with a wire cutting.
5) Disconnect the leadwire from the turntable motor
terminals.
6) Remove the screw securing the turntable motor to
the oven cavity ASS’Y
7) After repairing the motor, rotate the removed
turntable motor cover.
8) Fit the turntable motor cover’s projecting part to the
base plate slit.
NOTE:
1. Remove the wire lead from the turntable motor
VERY CAREFULLY.
2. Be sure to grasp the connector, not the wires, when
removing.
Wire Leads
Turntable Motor
H.V.
Capacitor
H.V.
Transformer
Suction
Guide
Fan Motor ASS'Y
K. C-MOTOR, THERMISTOR AND
SHEATH HEATER REMOVAL
1) Remove the two screws securing the cover
assembly to the oven cavity.
2) Disconnect the leadwire from the circulation motor
terminal and the sheath heater.
3) Remove the screws of the thermistor, guide assy-
chamber and lift up the guide assy-chamber.
4) Remove a hex nut securing the circulation fan to
shaft of the C-motor.
5) Remove screws securing the motor bracket to the
guide assy-chamber.
6) Remove two hex nuts securing the C-motor to the
motor bracket.
L. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASS’Y to
the control panel.
3) Take off the PCB SUB ASS’Y from the control
panel.
M. INTERLOCK SYSTEM
1) INTERLOCK MECHANISM
The door lock mechanism is a device which has
been specially designed to eliminate completely
microwave activity when the door is opened during
cooking and thus to prevent the danger resulting
from the microwave leakage.
2) MOUNTING OF THE PRIMARY/MONITOR/
SECONDARY SWITCHES TO THE LATCH BOARD
3) INSTALLATION AND ADJUSTMENT OF THE
LATCH BOARD TO THE OVEN ASSEMBLY
• Mount the latch board to the oven assembly.
• Adjust the latch board in the arrow direction so that
oven door will not have any play in it when the door
is closed.
• Tighten the mounting screw.
5-6
Latch Board
Secondary Interlock Switch
Interlock Monitor Switch
Primary Interlock Switch
A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible click should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open  circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make
the necessary adjustment or replace the switch
only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION 
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH 
TYPE NO. SZM-V 16-FA-61 OR VP-531A-OF FOR MONITOR SWITCH 
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
INTERLOCK CONTINUITY TEST
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the switch
(Wire leads removed)
with a Multi-meter
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE: After checking for the continuity of switches, make sure that are
correctly connected.
Door
open
Door
close
COM
NO
COM
NC
COM  
NO
Page of 35