2. Connect the cable to the outdoor unit
1. Remove the control cover from the unit by
loosening the screw.
Connect the wires to the terminals on the control
board individually.
2. Secure the cable onto the control board with the
cord clamp.
3. Refix the control cover to the original position
with the screw.
4. Use a recognized circuit breaker 16A between
the power source and the unit. A disconnecting
device to adequately disconnect all supply lines
must be fitted.
Over 5mm
Terminal block
(Pillar terminal)
Holder for
connecting 
cable
Control cover 
Connecting cable
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened.
(If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal
function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductors.
Outdoor Unit
CAUTION
-36-
Operation
Name and Function-Remote Control
Remote Control
1
2
8
9
10
11
Heat pump model
Cooling model
Signal transmitter
3
4
5
6
7
OPERATION DISPLAY
Displays the operation conditions.
START/STOP BUTTON
Operation starts when this button is pressed and
stops when the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating (turns indoor fan on/off).
ROOM TEMPERATURE CHECKING
BUTTON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing
batteries.
1
2
3
4
5
6
7
8
9
10
11
Disassembly of the parts (Indoor unit)
Warning :
Disconnect the unit from power supply before making
any checks.
Be sure the power switch is set to “OFF”.
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
(9K Btu models: 2EA, 12K Btu models: 3EA).
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sensor
holder, Motor, Evaporator & P.C.B.
-37-
2. To remove the Control Box.
• Remove 2 or 4 securing screws.
• Pull the control box out from the chassis
carefully.
3. To remove the Discharge Grille.
• Remove the securing screw.
• Pressing the right side of the discharge grille
downward slightly, unhook the discharge grille.
• Pull the discharge grille out from the chassis
carefully.
• Unhook the left side of the discharge grille and
pull the discharge grille out from the chassis
carefully(only LS-J series)
4. To remove the Evaporator.
• Remove 3 screws securing the evaporator(at the
left 1EA, at the right 2EA).
• Remove 3 screws securing the evaporator (at
the left 2 EA, in the Eva Holder, at the right
1EA): only LS-J series
-38-