- 41 -
9. Set the pipings and the connecting cable to
the back of the chassis with the tubing 
holder.
• Hook the edge of tubing holder to tap on chas-
sis and push the bottom of tubing holder to be
engaged in the bottom of chassis.
10. Indoor unit installation.
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge
of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
Drain hose
Tubing holder
Taping
Piping
Push
2
Hook
1
Connecting
cable
Drain hose
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engages with their slots (sound click).
- 42 -
(3) Connecting Pipings and the cable to Outdoor unit
Outdoor unit
A-UNIT
Gas side piping
Liquid side piping
B-UNIT
Torque wrench
1) Connecting the pipings to the Outdoor
unit
1. Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
2. Finally, tighten the flare nut with torque
wrench until the wrench clicks.
• When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the
arrow on the wrench.
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of
wiring, be guided by the circuit diagram pasted on the inside of control box cover.
2) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductors.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the
wires.)
4) Specification of power source.
5) Confirm that electrical capacity is sufficient.
6) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the
normal function of a overload protection device.
• Proper starting power is not given to the compressor.
Pipe Size
Torque
Liquid Side (1/4")
1.8kg.m
Gas Side (3/8")
4.2kg.m
Gas Side (1/2")
5.5kg.m
- 43 -
1(L)
1(L)
2(N)
2(N)
1(L) 2(N)
3
3
Terminal on the OUTDOOR UNIT
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
A-UNIT
Terminal on the INDOOR UNIT
A-UNIT
Terminal on the INDOOR UNIT
Power cord
Power cord
Power cord
B-UNIT
Terminal on the INDOOR UNIT
B-UNIT
Terminal on the INDOOR UNIT
C-UNIT
3
3
1(L) 2(N)
3
1(L) 2(N)
3
2(N)
1(L)
1(L)
3(B)
2(N)
3(A)
1(L) 2(N)
1(L) 2(N)
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
A-UNIT
Power cord
Terminal on the INDOOR UNIT
B-UNIT
3
1(L) 2(N)
3
1(L)
2(N)
1(L)
2(N)
3
3
1(L)
2(N)
3
3
2(N)
2(N)
1(L)
1(L)
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
A-UNIT
1(L)
2(N)
1(L)
2(N)
3
4
3
4
Terminal on the INDOOR UNIT
B-UNIT
1(L)
2(N)
3
4
3
2(N)
4
1(L)
Outdoor unit
Terminal block
Over 5mm
Cover control
Connecting cable
Power cord
Holder for
power supply
cord
2) Connection of the cable
1. Remove the cover control from the unit by loosen-
ing the screw. 
Connect the wires to the terminals on the control
board individually as the following.
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the cover control to the original position with
the screw.
4. Use a recongnized circuit breaker between the
power source and the unit. A disconnection device
to adequately disconnect all supply lines must be
fitted.
Caution
If a power plug is not to be used, provide a circuit
breaker between power source and the unit as
shown below.
CAUTION
ø8.5mm
GN/YL
20mm
ø7.5mm
GN/YL
20mm
The power cord connected to the outdoor unit
should be complied with the following specifica-
tions (Rubber insulation, type H05RN-F
approved by HAR or SAA).
The connecting cable connected to the indoor
and outdoor unit should be complied with the
following specifications (Rubber insulation, type
H07RN-F approved by HAR or SAA).
NORMAL CROSS-
SECTIONAL AREA
0.75mm
2
NORMAL CROSS-
SECTIONAL AREA
2.5mm
or 3.5mm
2
Air
Conditioner
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
(14K, 15K, 17K, 19K, 20K, 21K)
Main power source
Main power source
Circuit Breaker
Use a  25A circuit
breaker or time
delay fuse.
(30K)
- 44 -
Pull the right and the left side.
Screw
Connecting cable
1) Checking the Drainage
1. Remove the Grille from the cabinet
• Set the up-and-down air direction louver to
open position(horizontally) by finger pressure.
• Remove the securing screws.
• To remove the Grille, pull lower the left and
right side of the grille toward you (slightly tilted)
and lift it straight upward.
2. Check the drainage
• Pour a glass of water on the evaporator.
• Ensure if water flows drain hose of indoor unit
without any leakage.
(4) Checking the Drainage and Pipe forming
Page of 102