LG LM-1460C2L_M / LM-1460H2L_M / LM-1560C2L_M / LM-1723C2L_M / LM-1963C2L_M / LM-1963H2L_M / LM-2163C2L_M / LM-2163H2L_M / LM-2063H3L_M / LM-2064C3L_M / LM-3063C3L_M / LM-3063H3L_M Service Manual ▷ View online
-50-
Operation
(1) Name and Function-Remote Control (Door Closed)
Signal transmitter
Transmits the signals
to the room air conditioner.
to the room air conditioner.
Remote Control
6
1
3
5
4
2
Flip-up door
(closed)
Signal transmitter
START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.
when the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high, or CHAOS.
low, medium, high, or CHAOS.
JET COOL
Used to start or stop the speed
cooling. (Speed cooling operates
super high fan speed in cooling mode.)
cooling. (Speed cooling operates
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
set the desired up/down airflow direction.
1
2
3
4
5
6
-51-
(2) Name and Function-Remote Control (Door Opened)
Signal transmitter
Transmits the signals
to the room air conditioner.
to the room air conditioner.
Remote Control
ON
OFF
SET
CANCEL
Signal transmitter
4
5
6
7
1
2
3
1
2
3
4
5
6
7
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained and
to cancel the Timer operation.
to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
(turns indoor fan on/off).
(turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
- 52 -
Disassembly of the parts (Indoor unit)
Warning :
Disconnect the unit from power supply before mak-
ing any checks.
Be sure the power switch is set to “OFF”.
Disconnect the unit from power supply before mak-
ing any checks.
Be sure the power switch is set to “OFF”.
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
• To remove the Grille, pull the lower left and right
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift
it straight upward.
it straight upward.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sen-
sor holder, Motor, Evaporator & P.C.B.
sor holder, Motor, Evaporator & P.C.B.
Screw
Power
Conductor
Conductor
Step Motor
Conductor
Conductor
Earth
Conductor
Conductor
Motor
Conductor
Conductor
Sensor
Conductor
Conductor
2. To remove the Control Box.
• Remove securing screws.
• Pull the control box out from the chassis care-
• Pull the control box out from the chassis care-
fully.
3. To remove the Discharge Grille.
• Pull the discharge grille out from the chassis
carefully.
4. To remove the Evaporator.
• Remove screws securing the evaporator and
the holder eva.
• Unhook the tab on the right inside of the chas-
sis at the same time, slightly pull the evapora-
tor toward you until the tab is clear of the slot.
tor toward you until the tab is clear of the slot.
5. To remove the Cross-Flow Fan
• Loosen the screw securing the cross-flow fan
to the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and
the fan motor, separate the fan motor from the
cross-flow fan.
cross-flow fan.
• Remove the left end of the cross-flow fan from
the self-aligning bearing.
- 53 -
Click on the first or last page to see other LM-1460C2L_M / LM-1460H2L_M / LM-1560C2L_M / LM-1723C2L_M / LM-1963C2L_M / LM-1963H2L_M / LM-2163C2L_M / LM-2163H2L_M / LM-2063H3L_M / LM-2064C3L_M / LM-3063C3L_M / LM-3063H3L_M service manuals if exist.