DOWNLOAD LG LM-1460C2L_M / LM-1460H2L_M / LM-1560C2L_M / LM-1723C2L_M / LM-1963C2L_M / LM-1963H2L_M / LM-2163C2L_M / LM-2163H2L_M / LM-2063H3L_M / LM-2064C3L_M / LM-3063C3L_M / LM-3063H3L_M Service Manual ↓ Size: 2.93 MB | Pages: 102 in PDF or view online for FREE

Model
LM-1460C2L_M LM-1460H2L_M LM-1560C2L_M LM-1723C2L_M LM-1963C2L_M LM-1963H2L_M LM-2163C2L_M LM-2163H2L_M LM-2063H3L_M LM-2064C3L_M LM-3063C3L_M LM-3063H3L_M
Pages
102
Size
2.93 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lm-3063h3l.zip
Date

LG LM-1460C2L_M / LM-1460H2L_M / LM-1560C2L_M / LM-1723C2L_M / LM-1963C2L_M / LM-1963H2L_M / LM-2163C2L_M / LM-2163H2L_M / LM-2063H3L_M / LM-2064C3L_M / LM-3063C3L_M / LM-3063H3L_M Service Manual ▷ View online

Trouble analysis
1. Check temperature difference between intake and discharge air and operating current.
All amount of refrigerant leaked out. 
Check refrigeration cycle.
Refrigerant leakage
Clog of refrigeration cycle
Defective compressor
Excessive amount of refrigerant
Normal
Notice:
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower
temperature difference is larger.
2. Check temperature and pressure of refrigeration cycle.
Notice:
1. The suction pressure is usually 4.5~6.0 kg/cm
2
G at normal condition.
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.
- 58 -
Cycle Troubleshooting Guide
Temp. difference 
: approx. 0°C
Current
: less than 80% of
rated current
Temp. difference 
: approx. 8°C
Current
: less than 80% of
rated current
Temp. difference 
: less than 8°C
Current
: over the rated
current
Temp. difference 
: over 8°C
Temp. Difference 
Operating Current
Suction pressure
Temperature
(Compared with
(Compared with
Cause of Trouble
Description
the normal value)
the normal value)
High
Defective compressor
Current is low.
Defective 4-way reverse valve
Normal
Excessive amount of 
High pressure does not quickly 
refrigerant
rise at the beginning of operation.
Insufficient amount of
Current is low.
Lower
Higher
refrigerant(Leakage)
Clogging
Current is low.
Higher
- 59 -
1. Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Electronic Parts Troubleshooting Guide 
Turn off Main Power
Turn on Main Power
Does "beeping" sound is made from the Indoor Unit?
Primarily, the operating condition of Micom is OK.
Check the voltage of power(About AC 220V/AC240V, 50Hz)
• Main power's voltage
• Voltage applied to the unit
• Connecting method of Indoor/Outdoor connecting
cable
• Check PWB Ass'y
- Fuse
- Pattern damage
- Varistor(ZNR01J)
Check the connection housing for contacting
• Connector related to CN-POWER
• Display PWB Ass'y Check
• Connector related to CN-TAB1, 
Compressor (LM-2163C2L/M)
Check each load(Indoor/Outdoor Fan Motor,
Compressor, Stepping Motor etc.) and contacting 
condition of related connector
PCB Board Operation Check
Items
• Power Transformer
(Outdoor unit)
- Input Voltage
- Output Voltage
‹X
• IC01D(7812) Output
(Indoor/Outdoor unit)
‹X
• IC02D(7805) Output
(Indoor/Outdoor unit)
‹X
• IC01A(KIA7036, Reset IC)
X01(8MHz)
• Replace Trans
• Replace IC01D
• Replace IC02D
• Replace faulty parts
- About AC220V/240V±10% - Check the power voltage
- About AC14±3V
• DC +12V
• DC +5V
• Voltage of Micom No. 2,
(DC +4.5V over) and Soldering condition.
Content
Remedy
NO
YES
(After 10 seconds)
- 60 -
Turn on Main Power
While the compressor has been stopped, the compressor does not
operate owing to the delaying function for 3 minutes after stopped.
Caused by other parts except the remote control
Cause by the remote control
When the mark(       ) is displayed in LCD screen, replace
battery.
Check the contact of CN-DISPI connector.
When the compressor stopped Indoor Fan is driven by a low speed.
At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the
low speed by force.)
Check DISP PWB Ass'y
- Voltage between CN DISP1 
¤
¤
: DC +5V
When the detect switch(double key) inside the remote 
controller door is fault, it is impossible to operate 
temperature regulating(
¡ª
/
¡
) and wind speed selecting.
Check the connecting circuit between the remote con-
troller MICOM (No. 
§
) - R17(2
) - IR LED - Q1 -
R16(2.2K
).
Check point
• Check the connecting circuit between PIN 
¤Ł
-
R01L(1K) - C01L(680PF) - MICOM PIN
• Check Receiver Ass'y
2. The product is not operate with the remote control.
- 61 -
3. When cooling does not operate
Turn on Main Power
Operate "Cooling Mode(     )" by setting the desired temperature of the
remote controller is less than one of the indoor temperature by 1°C at least.
When in Air Circulation Mode, Compressor/Outdoor Fan is stopped.
Check the sensor for indoor temperature is attached as close as to be
effected by the temperature of Heat Exchanger(EVA).
When the sensor circuit for indoor temperature and connector are in bad
connection or are not engaged, Compressor/Outdoor Fan is stopped.
• Check the related circuit of R02H(12.1K), R01H(1.0K), R04H(6.2K),
R03H(1.0K) (Indoor unit).
• Check the indoor temperature sensor is disconnected or not(About 10k
/ at 25°C).
Check Outdoor Unit
Check Relay(RY - COMP) for driving compressor.
• When the power(About AC220V/240V) is applied to the connecting wire
terminal support transferred to compressor, PWB Ass'y is normal.
• Check the circuit related to the relay.
Check point
COMP ON
COMP OFF
Below DC 1V
About DC12V
(app)
Between two pin of DC
part in relay for COMP
Page of 102
Display

Click on the first or last page to see other LM-1460C2L_M / LM-1460H2L_M / LM-1560C2L_M / LM-1723C2L_M / LM-1963C2L_M / LM-1963H2L_M / LM-2163C2L_M / LM-2163H2L_M / LM-2063H3L_M / LM-2064C3L_M / LM-3063C3L_M / LM-3063H3L_M service manuals if exist.