LG AS-H126U / LS-C126U / LS-H126U Service Manual ▷ View online

18
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Front panel
Panel hook
Air filters
Air filters
Gasoline
Powder
Indoor Unit
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or discoloration.
• Volatile substances
Could damage the surfaces of the air conditioner.
1. Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
2. Clean the filter with a vacuum cleaner or warm,
soapy water.
• If dirt is conspicuous, wash with a solution of
detergent in lukewarm water.
• If hot water (40°C or more) is used, it may be
deformed.
3. After washing with water, dry well in the shade.
4. Re-install the air filter. 
1. After removing the air filters, pull slightly forward to
remove the PLASMA filter.
2. Dip the PLASMA filter into the water mixed with
neutral detergent, for 20~30 minutes.
3. Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed
perfectly on this parts).
4. Note the cuts of electric discharge lines.
5. Re-install the PLASMA filter to the original position.
Open the upside of Front Panel
1
Relocate dried air filters at the shade and then
close the panel.
5
Put up the Front panel.
The hook of panel comes off.
2
Come down the panel and then remove 
air filters.
3
Do cleaning by soft brush and a vacuum
cleaner. If it has hard pollution, wash by
water.
4
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
19
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Front panel
Panel
hook
Plasma
filters
(Side)
(Rear)
Air intake
vents
Air outlet
vents
(Side)
(Rear)
Drain Hose
Air intake vents
Air outlet vents
Piping
(Side)
(Rear)
Piping
Drain Hose
Air intake
vents
Air outlet
vents
Piping
Drain Hose
Outdoor Unit
The heat exchanger coils and panel vents of the
outdoor unit should be checked regularly. If clogged
with dirt or soot, the heat exchanger and panel 
vents may be professionally steam cleaned.
NOTE:
Dirty or clogged coils will reduce the 
operating efficiency of the system and cause
higher operating costs.
Cleaning of Purifying Filter
• Recomended use period : About 3 months
Open the upside of Front
panel.
Put up the front panel.
The hook of panel comes off.
Remove air filters and then
pull out plasma filter
3
2
1
Put in plasma filters in the
neutral detergent for 1~2
hours and then raise them.
Relocate dried plasma filters
at the shade and then put in
air filters.
5
4
ENGLISH
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
2
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
Safety precautions
Safety Precautions
Warning ................................2
Caution .................................3
Operating Instructions
Preparation before operation ..4
Remote Control Features .....6
Operation Mode Selection ......7
Additional features ..............14
Care and Maintenance
Care and Maintenance .......18
Operation Tips ....................20
Troubleshooting tips
Before You 
Call For Service 
...............21
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions will cause harm or
damage, the seriousness of which is indicated by the following
symbols.
This symbol shows the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to
property.
■ 
The following items are classified by these symblos.
Never Do This
Always Do This
Plug in the power plug
properly.
Do not operate or stop the unit by
inserting or pulling out the power plug.
Do not damage or use an
unspecified power cord.
• Otherwise, it will cause electric shock
or fire due to heat generation or
electric shock.
• It will cause electric shock or fire due
to heat generation.
• It will cause electric shock or fire.
• In the supply cord is damaged, it mut
be replaced by the manufacturer or
its service agent or a similarly
quallfied person in order to avoid a
hazard. (Y Attachment)
Do not modify power cord length or
share the outlet with other appliances.
Do not operate with wet hands or in
damp environment.
Do not direct airflow at room occupants
only.
• It will cause electric shock or fire due
to heat generation.
• It may cause electric shock.
• This could damage your health.
Always perform grounding work.
Do not allow water to run into
electric parts.
Always install air leakage breaker
and a dedicated switching board.
• No grounding may cause electric
shock.
• It may cause failure of machine or
electric shock.
• No installation may cause fire and
electric shock accident.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
Do not use the socket if it is
loose or damaged.
Do not open the entrance
during operation.
• It may cause fire and electric
shock accident.
• It may cause fire and electric
shock.
• It may cause electric shock.
Keep firearms away.
Do not use the power cord close to the
heating tools.
Do not use the power cord near flammable
gas or combustibles, such as gasoline,
benzene, thinner, etc.
• It may cause fire.
• It may cause fire and electric shock.
• It may cause an explosion or fire.
20
CAUTION
CAUTION
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Operate the air conditioner on Air circulation
mode (Refer to page 15) for 2 to 3 hours.
• This will dry out the internal mechanisms.
When air conditioner is not going to be 
used for a long time.
When the air conditioner is to be used again.
Turn off the circuit breaker, and disconnect
the plug.
Remove the batteries from the remote
control.
When the air conditioner is not going to be used for a long time.
Turn off the circuit breaker when the air conditioner
is not going to be used for a long time. 
Dirt may collect and may cause a fire.
Clean the air filter and install it in the indoor
unit.
(Refer to page 18 for cleaning filters.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Do not overcool the room.
This is not good for the health
and wastes electricity.
Make sure that the doors 
and windows are shut tight.
Avoid opening doors and
windows as much as possible
to keep the cool air in the room.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Clean the air filter regularly.
Blockages in the air filter
reduces the airflow and lowers
the cooling and dehumidifying
effects. Clean at least once in
every two weeks.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature
in the room.
Ventilate the room
occasionally.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
Operation Tips
Page of 127
Display