JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 9 of 28
All-pole switch or circuit breaker with >3mm contact
separation
separation
N
8.19.2
Mains switch ON indication
No mains switch
N
8.20
Switch not fitted in the mains cord
No mains switch
N
8.21
Bridging components comply with clause 14
N
8.22
Non-separable thin sheet material
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
–
9.1
Testing on the outside
–
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
The test finger or the test
pin can’t touch high voltage
pin can’t touch high voltage
N
9.1.1.1
a) Open circuit voltages
N
b) Touch current measured from terminal devices
using the network in annex D .................................:
using the network in annex D .................................:
N
c) Discharge not exceeding 45 μC
N
d) Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
N
9.1.2
No hazardous live shafts of knobs, handles or levers
N
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
N
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
wire (1 N); test probe D of IEC 61032
N
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test pin
(10 N); test probe C of IEC 61032
(10 N); test probe C of IEC 61032
N
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ...................:
of the mains plug; voltage (V) after 2 s ...................:
N
If C is not greater than 0,1 μF no test needed
N
9.1.7
a) Enclosure sufficiently resistant to external force
N
Test probe 11 of IEC 61032 for 10 s (50 N)
N
b) Test hook of fig. 4 for 10 s (20 N)
N
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Test with test tool results in
no hazard
no hazard
N
9.2
No hazard after removing a cover by hand
No cover removable by
hand
hand
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 10 of 28
10 INSULATION
REQUIREMENTS
–
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N
10.2 Humidity
treatment 48 h or 120 h ...........................:
48 h at temp.30°C and
relative humidity 93%.
relative humidity 93%.
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
N
11 FAULT
CONDITIONS
–
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
(see appended table)
P
No hazard from softening solder
No softening of solder
N
Flames extinguish within 10 seconds
N
Soldered terminations not used as protective
mechanism
mechanism
N
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for max.
5 min
exceeding the limits of table 3 by max. 100 K for max.
5 min
No exceeding the limits of
Table 3.
Table 3.
N
a) Temperature rise of printed circuit boards (PCB) to
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB) to
20.1.3 up to 300 K for an area not greater than 2 cm²
for a maximum of 5 min
20.1.3 up to 300 K for an area not greater than 2 cm²
for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are
interrupted/peeled/loosened
during fault condition
interrupted/peeled/loosened
during fault condition
N
Class I protective earthing maintained
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 11 of 28
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
No excessive temperature
observed /measured on
other parts (see appended
table).
observed /measured on
other parts (see appended
table).
P
12 MECHANICAL
STRENGTH
–
12.1.1
Bump test where mass >7 kg
Mass less than 7Kg
N
12.1.2 Vibration
test
No hazardous after
vibration test
vibration test
P
12.1.3
Impact hammer test
No damage in the sense of
this standard
this standard
P
Steel ball test
No damage in the sense of
this standard
this standard
P
12.1.4
Drop test for portable apparatus where mass < 7 kg
N
12.1.5
Thermoplastic enclosures strain relief test
Metal enclosure
N
12.2
Fixing of knobs, push buttons, keys and levers
No damage in the sense of
this standard
this standard
P
12.3
Remote controls with hazardous live parts
No hazardous live parts.
P
12.4
Drawers (pull test 50 N, 10 s)
No drawers.
N
12.5
Antenna coaxial sockets providing isolation
No damage in the sense of
this standard
this standard
N
12.6
Telescoping or rod antennas construction
No telescoping or rod
antennas
antennas
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
–
13.1
Clearances in accordance with 13.3
See 13.3
–
Creepage distances in accordance with 13.4
See 13.4
–
13.2
Determination of operating voltage
N
13.3 Clearances
N
13.3.1 General
N
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
N
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 12 of 28
13.3.4
Measurement of transient voltages
N
13.4 Creepage
distances
N
Creepage distances greater than table 11 minima
Not applicable
N
13.5
Printed boards
No such PCB used
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N
13.6
Conductive parts along uncemented joints clearances
and creepage distances comply with 13.3 and 13.4
and creepage distances comply with 13.3 and 13.4
No uncemented joints
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
Temperature cycle test and dielectric strength test
N
13.7
Enclosed, enveloped or hermetically sealed parts: not
conductively connected to the mains: clearances and
creepage distances as in table 12
conductively connected to the mains: clearances and
creepage distances as in table 12
No such part used
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
14 COMPONENTS
–
14.1 Resistors
–
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistor
N
b) Resistors, other than between hazardous live parts
and accessible parts
and accessible parts
No such resistors
N
Resistors
separately approved ...............................: No
N
14.2
Capacitors and RC units
–
Capacitors separately approved
Yes, see below
–
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...:
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...:
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
connected to the mains: tests for X2 ......................:
No such capacitors
N