JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 13 of 28
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better :
Capacitor by metal
enclosure.
enclosure.
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
N
Shielded by a barrier acc. to 20.1.4/ table 21 or metal
..................................................................................:
N
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
N
Transformers and inductors separately approved .:
N
14.3.2 General
N
Insulation material complies with clause 20.1.4
Isolating transformers
N
14.3.3 Constructional
requirements
N
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Transformer complied with
clause 13.
clause 13.
N
14.3.3.2
Transformers meet the constructional requirements
Check by inspection
N
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of 14.3.4.2
are met
protective screening only if all 7 conditions of 14.3.4.2
are met
N
14.3.4.3
Separating transformers with at least basic insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 14 of 28
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
No high-voltage
components.
components.
N
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
No such high-voltage.
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
P
Protective devices used within their ratings
Mains fuse,
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Mains fuse,
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs
N
b) Thermal cut-outs tested as part of the submission
N
14.5.1.2
a) Thermal links separately approved
No thermal links
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices re-
settable
settable
N
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127 The mains fuse certified by
UL
N
14.5.2.2
Correct marking of fuse-links adjacent to holder ....:
P
14.5.2.3
Not possible to connect fuses in parallel ................:
Not possible to connect
fuses in parallel
fuses in parallel
N
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
No replacement of fuse
possible by hand.
possible by hand.
N
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC-S thermistors
N
PTC-S devices (15 W) category V-1 or better
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N
14.6 Switches
No
switches
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 15 of 28
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
subclause 13.1 and has making/breaking action
independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N
Socket outlet current marking correct
N
14.7
Safety interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices and the like
No voltage setting devices.
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
No
motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 16 of 28
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N
14.10 Batteries
No
batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within manufacturers
limits
limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
N
N
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N
Comply with IEC 61051-2
N
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
15 TERMINALS
–
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
N
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
N