EMC - CB Certificate
Brand
Device
Car Audio
File
gto-14001-sm3.pdf
Date

JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online

 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 13 of 28 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better   : 
Capacitor by metal 
enclosure. 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better .................................................: 
 N 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or metal 
..................................................................................: 
 N 
14.3 
Inductors and windings 
 
P  
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
 N 
 
Transformers and inductors separately approved  .: 
 
14.3.2 General 
 
 
Insulation material complies  with clause 20.1.4 
Isolating transformers 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
Transformer complied with 
clause 13. 
14.3.3.2 
Transformers meet the constructional requirements 
Check by inspection 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 14.3.4.2 
are met 
 N 
14.3.4.3 
Separating transformers with at least basic insulation   
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 14 of 28 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
No high-voltage 
components. 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved 
No such high-voltage. 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Mains fuse,  
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Mains fuse,  
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs 
 
b) Thermal cut-outs tested as part of the submission 
 
14.5.1.2 
a) Thermal links separately approved 
No thermal links 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No thermal devices re-
settable 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 60127 The mains fuse certified by 
UL 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ....: 
 
14.5.2.3 
Not possible to connect fuses in parallel  ................: 
Not possible to connect 
fuses in parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
No replacement of fuse 
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC-S thermistors 
 
PTC-S devices (15 W) category V-1 or better 
 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 
14.6 Switches 
No 
switches 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 15 of 28 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
Make and break speed independent of speed of 
actuation 
V-0 compliance with annex G, G.1.1 
 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and 
V-0 in annex G, G.1.1 
 
 
Switch controlling > 0.2A with open contact  voltage < 
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in 
annex G, G.1.1 
 
 
Switch controlling < 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with  14.6.4 and V-0 in 
annex G, G.1.1 
         
 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-1 
subclause 13.1 and has making/breaking  action 
independent of speed of actuation 
         
 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-1 
subclause 16.2.2 d) and  m) not attaining excessive 
temperatures in use 
         
 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
         
 
 
Socket outlet current marking correct 
         
 
14.7 
Safety interlocks 
No safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
         
 
14.8 
Voltage setting devices and the like 
No voltage setting devices. 
 
Voltage setting device not likely to be changed 
accidentally 
         
 
14.9 Motors 
No 
motors 
14.9.1 
Endurance test on motors 
         
 
 
Motor start test 
         
 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 16 of 28 
 
Dielectric strength test 
         
 
14.9.2 
Not adversely affected by oil or grease etc. 
         
 
14.9.3 
Protection against moving parts 
         
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
         
 
14.10 Batteries 
No 
batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
         
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
         
 
14.10.3 
Recharging currents and times within manufacturers 
limits 
         
 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
         
 
14.10.4 
Battery mould stress relief 
 
14.10.5 
Battery drop test 
 
14.11 Optocouplers 
 N 
 
Optocouplers comply with Cl. 8 
 
 
 
14.12 
Surge suppression varistors 
No surge suppression 
varistors 
 
Comply with IEC 61051-2 
 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus 
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
 
15 TERMINALS 
– 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard 
 
N  
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets 
 
Page of 29
Display